{"id":16425,"date":"2025-12-04T17:20:39","date_gmt":"2025-12-05T01:20:39","guid":{"rendered":"https:\/\/www.dtflinko.com\/?page_id=16425"},"modified":"2026-04-10T18:03:36","modified_gmt":"2026-04-11T02:03:36","slug":"instrukcja-wymiany-zasilacza-24-v-serii-k60","status":"publish","type":"page","link":"https:\/\/www.dtflinko.com\/pl\/technical-services\/printer-technical-operation-repair\/k60-series-24v-power-supply-inspection-replacement-guide\/","title":{"rendered":"Seria K60\uff5cPrzewodnik po inspekcji i wymianie zasilacza 24 V"},"content":{"rendered":"<section class=\"section\" id=\"section_138630588\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row\"  id=\"row-2076516081\">\n\n\t<div id=\"col-1264939150\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div id=\"text-2184184681\" class=\"text\">\n\t\t\n<h1>Seria K60\uff5cPrzewodnik po inspekcji i wymianie zasilacza 24 V<\/h1>\n\t\t\n<style>\n#text-2184184681 {\n  text-align: left;\n}\n@media (min-width:850px) {\n  #text-2184184681 {\n    text-align: center;\n  }\n}\n<\/style>\n\t<\/div>\n\t\n<p>Dotyczy modeli: drukarek DTF serii LINKO K60<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-593152234\">\n\n\t<div id=\"col-307062822\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h2>1. <strong>Przegl\u0105d modu\u0142u zasilania<\/strong>:<\/h2>\n<p>Wewn\u0105trz drukarki zastosowano wiele modu\u0142\u00f3w zasilania, aby zapewni\u0107 r\u00f3\u017cne napi\u0119cia dla r\u00f3\u017cnych system\u00f3w.<\/p>\n<p>Zasilacz 24 V (Zasilacz 24 V)<br \/>Zapewnia pr\u0105d sta\u0142y 24 V dla:<\/p>\n<ul>\n<li>Pompa cyrkulacyjna bia\u0142ego tuszu<\/li>\n<li>Silnik mieszaj\u0105cy bia\u0142y tusz<\/li>\n<\/ul>\n<p>Inne modu\u0142y zasilania<br \/><strong>Zasilanie 36 V:<\/strong> Nap\u0119dza silniki X\/Y i sterowniki silnik\u00f3w<br \/><strong>G\u0142\u00f3wny modu\u0142 zasilania:<\/strong> Dostarcza wielowyj\u015bciowe napi\u0119cie sta\u0142e (42 V \/ 36 V \/ 24 V) do p\u0142yty g\u0142\u00f3wnej, p\u0142yty w\u00f3zka, sto\u0142u pr\u00f3\u017cniowego, wentylator\u00f3w ch\u0142odz\u0105cych, ekranu wy\u015bwietlacza i automatycznego podno\u015bnika.<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Module-Overview.webp\" title=\"1-Przegl\u0105d modu\u0142u zasilania\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Module-Overview-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Przegl\u0105d modu\u0142u zasilaniaa\" ids=\"16430\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Module-Overview-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Module-Overview-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Module-Overview-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Module-Overview-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Module-Overview-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Module-Overview-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Module-Overview.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>1-Przegl\u0105d modu\u0142u zasilania<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-800185164\">\n\n\t<div id=\"col-1711897630\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h2>2. Schemat pod\u0142\u0105czenia skrzynki zasilaj\u0105cej 24V<\/h2>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/24V-Power-Supply-Wiring-Diagram.webp\" title=\"Schemat okablowania zasilacza 2-1-24V\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/24V-Power-Supply-Wiring-Diagram-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Schemat okablowania zasilacza 24 V\" ids=\"16431,17511\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/24V-Power-Supply-Wiring-Diagram-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/24V-Power-Supply-Wiring-Diagram-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/24V-Power-Supply-Wiring-Diagram-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/24V-Power-Supply-Wiring-Diagram-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/24V-Power-Supply-Wiring-Diagram-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/24V-Power-Supply-Wiring-Diagram-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/24V-Power-Supply-Wiring-Diagram.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>Schemat okablowania zasilacza 2-1-24V<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-24V-Power-Supply-Wiring-Diagram-Chinese.webp\" title=\"Schemat okablowania zasilacza 2-2-24V (chi\u0144ski)\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-24V-Power-Supply-Wiring-Diagram-Chinese-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Schemat okablowania zasilacza 24 V serii K60 w wersji chi\u0144skiej\" ids=\"16431,17511\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-24V-Power-Supply-Wiring-Diagram-Chinese-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-24V-Power-Supply-Wiring-Diagram-Chinese-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-24V-Power-Supply-Wiring-Diagram-Chinese-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-24V-Power-Supply-Wiring-Diagram-Chinese-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-24V-Power-Supply-Wiring-Diagram-Chinese-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-24V-Power-Supply-Wiring-Diagram-Chinese-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-24V-Power-Supply-Wiring-Diagram-Chinese.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>Schemat okablowania zasilacza 2-2-24V (chi\u0144ski)<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-2119729344\">\n\n\t<div id=\"col-1588700625\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<table width=\"913\">\n<tbody>\n<tr>\n<td width=\"369\"><span style=\"color: #000000;\">Kategoria<\/span><\/td>\n<td width=\"39\"><span style=\"color: #000000;\">Nie.<\/span><\/td>\n<td width=\"103\"><span style=\"color: #000000;\">Interfejs<\/span><\/td>\n<td width=\"87\"><span style=\"color: #000000;\">ID<\/span><\/td>\n<td width=\"315\"><span style=\"color: #000000;\">Opis<\/span><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\"><span style=\"color: #000000;\">Wej\u015bcie AC (zasilanie zewn\u0119trzne \u2192 zasilacz 24 V)<\/span><\/td>\n<td><span style=\"color: #000000;\">\u2462<\/span><\/td>\n<td><span style=\"color: #000000;\">Ziemia (G)<\/span><\/td>\n<td><span style=\"color: #000000;\">\u2013<\/span><\/td>\n<td><span style=\"color: #000000;\">Uziemienie \/ Ochrona bezpiecze\u0144stwa<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"color: #000000;\">\u2461<\/span><\/td>\n<td><span style=\"color: #000000;\">Neutralny (N)<\/span><\/td>\n<td><span style=\"color: #000000;\">AC-N1<\/span><\/td>\n<td><span style=\"color: #000000;\">\u015acie\u017cka powrotna pr\u0105du przemiennego<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"color: #000000;\">\u2460<\/span><\/td>\n<td><span style=\"color: #000000;\">Na \u017cywo (L)<\/span><\/td>\n<td><span style=\"color: #000000;\">AC-L1<\/span><\/td>\n<td><span style=\"color: #000000;\">Wej\u015bcie pr\u0105du przemiennego<\/span><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\"><span style=\"color: #000000;\">Wyj\u015bcie pr\u0105du sta\u0142ego (zasilanie 24 V \u2192 silnik pompy\/mieszad\u0142a)<\/span><\/td>\n<td><span style=\"color: #000000;\">\u2464<\/span><\/td>\n<td><span style=\"color: #000000;\">24V dodatnie<\/span><\/td>\n<td><span style=\"color: #000000;\">\u2013<\/span><\/td>\n<td><span style=\"color: #000000;\">Wyj\u015bcie do pompy obiegowej\/silnika mieszaj\u0105cego (+)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"color: #000000;\">\u2463<\/span><\/td>\n<td><span style=\"color: #000000;\">24V ujemny<\/span><\/td>\n<td><span style=\"color: #000000;\">\u2013<\/span><\/td>\n<td><span style=\"color: #000000;\">Wyj\u015bcie do pompy obiegowej\/silnika mieszaj\u0105cego (\u2013)<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1395225344\">\n\n\t<div id=\"col-1659899652\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h2>3. Procedura rozwi\u0105zywania problem\u00f3w (WA\u017bNE: Najpierw przetestuj pr\u0105d przemienny \u2192 nast\u0119pnie pr\u0105d sta\u0142y)<\/h2>\n<p><strong>\u26a0 Wa\u017cna informacja<\/strong><br \/>Je\u017celi na zaciskach \u2460\u2013\u2461 nie ma napi\u0119cia wej\u015bciowego pr\u0105du przemiennego, napi\u0119cie wyj\u015bciowe pr\u0105du sta\u0142ego na zaciskach \u2463\u2013\u2464 zawsze b\u0119dzie wynosi\u0107 0 V.<\/p>\n<p>To jest normalne i <strong>nie oznacza to, \u017ce zasilanie 24 V jest uszkodzone<\/strong>.<br \/>Zawsze testuj <strong>Najpierw wej\u015bcie pr\u0105du przemiennego<\/strong>, a nast\u0119pnie przetestuj <strong>Wyj\u015bcie pr\u0105du sta\u0142ego<\/strong>.<\/p>\n<h3>3.1 Ostrze\u017cenie dotycz\u0105ce bezpiecze\u0144stwa<\/h3>\n<ul>\n<li>Podczas pomiaru napi\u0119cia drukarka musi by\u0107 w\u0142\u0105czona.<\/li>\n<li>Podczas wymiany zasilacza zasilanie musi by\u0107 WY\u0141\u0104CZONE<\/li>\n<li>Nale\u017cy nosi\u0107 r\u0119kawice izolacyjne i unika\u0107 dotykania ods\u0142oni\u0119tych obwod\u00f3w.<\/li>\n<\/ul>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On.webp\" title=\"3.1-W\u0142\u0105czanie\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"W\u0142\u0105cz zasilanie\" ids=\"16433\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.1-W\u0142\u0105czanie<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<h3>3.2 Sprawd\u017a wej\u015bcie pr\u0105du przemiennego (\u2460\u2013\u2461)<\/h3>\n<p>Tryb multimetru: <strong>Pr\u0105d zmienny 600 V<\/strong><br \/>Punkty testowe:<\/p>\n<ul>\n<li>Czarna sonda \u2192 \u2461 (AC-N1)<\/li>\n<li>Czerwona sonda \u2192 \u2460 (AC-L1)<\/li>\n<\/ul>\n<p>Normalne: pr\u0105d zmienny 200\u2013240 V<br \/>\u2192 Wej\u015bcie AC jest prawid\u0142owe. Przejd\u017a do testu wyj\u015bcia DC.<\/p>\n<p>Nieprawid\u0142owe: 0 V lub niestabilne napi\u0119cie<br \/>\u2192 To nie jest awaria zasilania. Prosz\u0119 sprawdzi\u0107:<\/p>\n<ul>\n<li>G\u0142\u00f3wny wy\u0142\u0105cznik zasilania WY\u0141\u0104CZONY<\/li>\n<li>Zatrzymanie awaryjne nie zosta\u0142o zwolnione<\/li>\n<li>Gniazdko \u015bcienne nie ma pr\u0105du<\/li>\n<li>Lu\u017ane okablowanie pr\u0105du przemiennego<\/li>\n<li>Utlenianie ko\u0144cowe<\/li>\n<li>Uszkodzenie kabla<\/li>\n<\/ul>\n<h3>3.3 Sprawd\u017a wyj\u015bcie pr\u0105du sta\u0142ego (\u2463\u2013\u2464)<\/h3>\n<p>Tryb multimetru: <strong>Pr\u0105d sta\u0142y 200 V<\/strong><br \/>Punkty testowe:<\/p>\n<ul>\n<li>Czerwona sonda \u2192 \u2464 (24V +)<\/li>\n<li>Czarna sonda \u2192 \u2463 (24V \u2013)<\/li>\n<\/ul>\n<div class=\"row\"  id=\"row-1342254066\">\n\n\t<div id=\"col-1555274130\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-DC-Output-Test-Points.webp\" title=\"3.3-Pomiar wyj\u015bcia pr\u0105du sta\u0142ego (punkty testowe \u2463\u2013\u2464)\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-DC-Output-Test-Points-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Pomiar punkt\u00f3w testowych wyj\u015bcia pr\u0105du sta\u0142ego\" ids=\"16434\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-DC-Output-Test-Points-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-DC-Output-Test-Points-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-DC-Output-Test-Points-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-DC-Output-Test-Points-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-DC-Output-Test-Points-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-DC-Output-Test-Points-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-DC-Output-Test-Points.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.3-Pomiar wyj\u015bcia pr\u0105du sta\u0142ego (punkty testowe \u2463\u2013\u2464)<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>3.3.1 Wyniki test\u00f3w i ocena wyj\u015bcia pr\u0105du sta\u0142ego<\/p>\n<table>\n<thead>\n<tr>\n<th>Wynik wyj\u015bcia DC<\/th>\n<th>Status<\/th>\n<th>Dzia\u0142anie<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>22\u201325 V (\u00b110%) (pompa\/silnik mieszad\u0142a ma normalne napi\u0119cie wej\u015bciowe)<\/td>\n<td>\u2705 Napi\u0119cie wyj\u015bciowe zasilacza 24 V jest normalne<\/td>\n<td>Nie ma potrzeby wymiany<\/td>\n<\/tr>\n<tr>\n<td>22\u201325 V (\u00b110%), ale pompa\/silnik mieszaj\u0105cy nie dzia\u0142a<\/td>\n<td>\u2705 Zasilanie jest normalne \u2192 problem nie wyst\u0119puje tutaj<\/td>\n<td>Sprawd\u017a napi\u0119cie wej\u015bciowe pompy\/silnika<\/td>\n<\/tr>\n<tr>\n<td>0 V lub bardzo niskie (potwierdzono, \u017ce napi\u0119cie wej\u015bciowe AC jest prawid\u0142owe)<\/td>\n<td>\u274c Awaria wewn\u0119trzna zasilacza 24 V<\/td>\n<td>Wymie\u0144 zasilacz 24 V<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-DC-Output-22-25V.webp\" title=\"3.3.1-1-Normalne wyj\u015bcie pr\u0105du sta\u0142ego (22-25 V)\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-DC-Output-22-25V-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Normalne wyj\u015bcie DC 22 25 V\" ids=\"16435\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-DC-Output-22-25V-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-DC-Output-22-25V-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-DC-Output-22-25V-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-DC-Output-22-25V-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-DC-Output-22-25V-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-DC-Output-22-25V-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-DC-Output-22-25V.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.3.1-1-Normalne wyj\u015bcie pr\u0105du sta\u0142ego (22-25 V)<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Abnormal-0.0V.webp\" title=\"3.3.1-2 Wyj\u015bcie DC - nieprawid\u0142owe (0,0 V)\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Abnormal-0.0V-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Wyj\u015bcie DC nieprawid\u0142owe 0 0V\" ids=\"16438\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Abnormal-0.0V-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Abnormal-0.0V-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Abnormal-0.0V-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Abnormal-0.0V-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Abnormal-0.0V-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Abnormal-0.0V-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Abnormal-0.0V.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.3.1-2 Wyj\u015bcie DC - nieprawid\u0142owe (0,0 V)<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>3.3.2 Dalszy test napi\u0119cia wej\u015bciowego pompy\/silnika mieszad\u0142a<\/p>\n<table>\n<thead>\n<tr>\n<th>Napi\u0119cie wej\u015bciowe<\/th>\n<th>Os\u0105d<\/th>\n<th>Dzia\u0142anie<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>0,0 V<\/td>\n<td>Brak napi\u0119cia w pompie\/silniku mieszad\u0142a \u2192 uszkodzone okablowanie\/utlenianie zacisk\u00f3w<\/td>\n<td>Sprawd\u017a lub wymie\u0144 okablowanie<\/td>\n<\/tr>\n<tr>\n<td>22\u201325 V (\u00b110%), ale pompa\/silnik nie dzia\u0142a<\/td>\n<td>Awaria pompy lub silnika mieszaj\u0105cego<\/td>\n<td>Wymie\u0144 pomp\u0119 obiegow\u0105 lub silnik mieszaj\u0105cy<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-Voltage-at-PumpStirring-Motor-Input.webp\" title=\"3.3.2 Pomiar napi\u0119cia na wej\u015bciu pompy i silnika mieszaj\u0105cego\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-Voltage-at-PumpStirring-Motor-Input-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Pomiar napi\u0119cia na wej\u015bciu silnika mieszaj\u0105cego pomp\u0119\" ids=\"16437\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-Voltage-at-PumpStirring-Motor-Input-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-Voltage-at-PumpStirring-Motor-Input-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-Voltage-at-PumpStirring-Motor-Input-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-Voltage-at-PumpStirring-Motor-Input-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-Voltage-at-PumpStirring-Motor-Input-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-Voltage-at-PumpStirring-Motor-Input-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-Voltage-at-PumpStirring-Motor-Input.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.3.2 Pomiar napi\u0119cia na wej\u015bciu pompy i silnika mieszaj\u0105cego<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1354455952\">\n\n\t<div id=\"col-1814484508\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h2>4. Wymiana zasilacza 24 V<\/h2>\n<h3>4.1 Wy\u0142\u0105cz drukark\u0119<\/h3>\n<ul>\n<li>Naci\u015bnij przycisk zatrzymania awaryjnego<\/li>\n<li>Wy\u0142\u0105cz g\u0142\u00f3wny wy\u0142\u0105cznik zasilania<\/li>\n<li>Od\u0142\u0105cz kabel zasilaj\u0105cy<\/li>\n<\/ul>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch.webp\" title=\"4.1-1-Wy\u0142\u0105cznik awaryjny\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Prze\u0142\u0105cznik awaryjny\" ids=\"16444,16445\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.1-1-Wy\u0142\u0105cznik awaryjny<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off.webp\" title=\"4.1-2-Wy\u0142\u0105czanie zasilania\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Wy\u0142\u0105cz zasilanie\" ids=\"16444,16445\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.1-2-Wy\u0142\u0105czanie zasilania<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<h3>4.2 Wyjmij stary zasilacz<\/h3>\n<p>4.2.1 Od\u0142\u0105czanie okablowania<\/p>\n<ul>\n<li>Odkr\u0119\u0107 zaciski \u2460\u2013\u2464 w kolejno\u015bci<\/li>\n<li>Wyjmij ka\u017cdy przew\u00f3d po kolei<\/li>\n<li>Zr\u00f3b wyra\u017ane zdj\u0119cia okablowania w celu ponownej instalacji<\/li>\n<\/ul>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Wiring-Record-Photo.webp\" title=\"4.2.1-Okablowanie-Nagrywanie-Zdj\u0119cie\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Wiring-Record-Photo-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Zdj\u0119cie rekordu okablowania\" ids=\"16446\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Wiring-Record-Photo-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Wiring-Record-Photo-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Wiring-Record-Photo-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Wiring-Record-Photo-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Wiring-Record-Photo-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Wiring-Record-Photo-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Wiring-Record-Photo.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.2.1-Okablowanie-Nagrywanie-Zdj\u0119cie<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>4.2.2 Wyjmij \u015bruby mocuj\u0105ce<\/p>\n<ul>\n<li>Wyjmij \u015brub\u0119 \u2460<\/li>\n<li>Odkr\u0119\u0107 \u015brub\u0119 ustalaj\u0105c\u0105 \u2461<\/li>\n<li>Wyjmij stary zasilacz<\/li>\n<\/ul>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Mounting-Screws.webp\" title=\"4.2.2-1-Luzowanie \u015brub mocuj\u0105cych\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Mounting-Screws-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Odkr\u0119canie \u015brub monta\u017cowych\" ids=\"16447,16448\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Mounting-Screws-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Mounting-Screws-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Mounting-Screws-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Mounting-Screws-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Mounting-Screws-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Mounting-Screws-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Mounting-Screws.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.2.2-1-Luzowanie \u015brub mocuj\u0105cych<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-24V-Power-Supply-Removed.webp\" title=\"4.2.2-2-Stary zasilacz 24 V-usuni\u0119ty\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-24V-Power-Supply-Removed-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Usuni\u0119to stary zasilacz 24 V\" ids=\"16447,16448\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-24V-Power-Supply-Removed-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-24V-Power-Supply-Removed-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-24V-Power-Supply-Removed-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-24V-Power-Supply-Removed-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-24V-Power-Supply-Removed-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-24V-Power-Supply-Removed-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-24V-Power-Supply-Removed.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.2.2-2-Stary zasilacz 24 V-usuni\u0119ty<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<h3>4.3 Zainstaluj nowy zasilacz<\/h3>\n<p>4.3.1 Potwierd\u017a zgodno\u015b\u0107 modelu<br \/>Sprawd\u017a, czy nowy zasilacz jest taki sam jak oryginalny (napi\u0119cie, moc, typ z\u0142\u0105cza).<\/p>\n<p>4.3.2 Monta\u017c Instalacja<br \/>Wyr\u00f3wnaj otwory monta\u017cowe \u2192 Zawie\u015b na szczelinie ustalaj\u0105cej \u2192 Dokr\u0119\u0107 wszystkie \u015bruby.<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Fixed-in-Position.webp\" title=\"4.3.2-Zasilanie-sta\u0142e-w-pozycji\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Fixed-in-Position-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Zasilacz zamocowany na sta\u0142e\" ids=\"16449\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Fixed-in-Position-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Fixed-in-Position-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Fixed-in-Position-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Fixed-in-Position-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Fixed-in-Position-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Fixed-in-Position-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Fixed-in-Position.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.3.2-Zasilanie-sta\u0142e-w-pozycji<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>4.3.3 Okablowanie<\/p>\n<ul>\n<li>Post\u0119puj zgodnie ze schematem okablowania (rysunek 2)<\/li>\n<li>W\u0142\u00f3\u017c ka\u017cdy przew\u00f3d ca\u0142kowicie do zacisku<\/li>\n<li>Upewnij si\u0119, \u017ce kierunek jest prawid\u0142owy i nie ma lu\u017anych po\u0142\u0105cze\u0144<\/li>\n<li>Mocno dokr\u0119\u0107 \u015bruby zaciskowe<\/li>\n<\/ul>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1626275522\">\n\n\t<div id=\"col-1437697013\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h2>5. Weryfikacja po w\u0142\u0105czeniu zasilania<\/h2>\n<p>5.1 Ponowna kontrola okablowania: Upewnij si\u0119, \u017ce wszystkie kable s\u0105 solidnie pod\u0142\u0105czone i nie s\u0105 odwr\u00f3cone.<\/p>\n<p>5.2 Pod\u0142\u0105cz kabel zasilaj\u0105cy \u2192 W\u0142\u0105cz g\u0142\u00f3wny wy\u0142\u0105cznik zasilania (patrz rysunek 3.1)<\/p>\n<p>5.3 Aby przywr\u00f3ci\u0107 zasilanie, przekr\u0119\u0107 wy\u0142\u0105cznik awaryjny zgodnie z ruchem wskaz\u00f3wek zegara (patrz rysunek 5.3).<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1.webp\" title=\"5-Wy\u0142\u0105cznik awaryjny\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Wy\u0142\u0105cznik awaryjny serii K60\" ids=\"16450\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>5-Wy\u0142\u0105cznik awaryjny<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>5.4 Ostateczna kontrola statusu<\/p>\n<p>Po wykonaniu wszystkich po\u0142\u0105cze\u0144 i w\u0142\u0105czeniu urz\u0105dzenia nale\u017cy wykona\u0107 poni\u017csze czynno\u015bci, aby sprawdzi\u0107, czy zasilacz dzia\u0142a prawid\u0142owo:<\/p>\n<ul>\n<li>Sprawd\u017a kontrolki na zasilaczu.<\/li>\n<li>Ponownie zmierz napi\u0119cie na zacisku wyj\u015bciowym 24 V za pomoc\u0105 woltomierza.<\/li>\n<\/ul>\n<p>Normalna praca<\/p>\n<ul>\n<li>Kontrolka jest w\u0142\u0105czona<\/li>\n<li>Wyj\u015bcie pr\u0105du sta\u0142ego: 22\u201325 V<\/li>\n<\/ul>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Normal-Situation.webp\" title=\"5.4-1-Sytuacja normalna\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Normal-Situation-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Normalna sytuacja\" ids=\"16451\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Normal-Situation-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Normal-Situation-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Normal-Situation-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Normal-Situation-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Normal-Situation-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Normal-Situation-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Normal-Situation.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>5.4-1-Sytuacja normalna<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>Nieprawid\u0142owa praca<\/p>\n<ul>\n<li>Kontrolka wy\u0142\u0105czona lub miga<\/li>\n<li>Napi\u0119cie sta\u0142e 0,0 V<\/li>\n<\/ul>\n<p>\u2192 Sprawd\u017a ponownie okablowanie lub wymie\u0144 zasilacz.<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Abnormal-Situation.webp\" title=\"5.4-2-Sytuacja nienormalna\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Abnormal-Situation-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Nietypowa sytuacja\" ids=\"16452\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Abnormal-Situation-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Abnormal-Situation-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Abnormal-Situation-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Abnormal-Situation-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Abnormal-Situation-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Abnormal-Situation-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Abnormal-Situation.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>5.4-2-Sytuacja nienormalna<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1515279123\">\n\n\t<div id=\"col-113226682\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<p><span style=\"color: #333399;\"><strong>Wsparcie techniczne LINKO<\/strong><\/span><\/p>\n<p>E-mail: <a href=\"mailto:support@dtflinko.com\">support@dtflinko.com<\/a><\/p>\n<p>Strona internetowa: <a href=\"https:\/\/www.dtflinko.com\/pl\/\">www.dtflinko.com<\/a><\/p>\n<p>\u00a9 2025 Zesp\u00f3\u0142 techniczny LINKO. Wszelkie prawa zastrze\u017cone.<\/p>\n<p>Powielanie lub modyfikacja bez zezwolenia jest zabroniona.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_138630588 {\n  padding-top: 60px;\n  padding-bottom: 60px;\n}\n<\/style>\n\t<\/section>","protected":false},"excerpt":{"rendered":"","protected":false},"author":3,"featured_media":0,"parent":15609,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-blank.php","meta":{"footnotes":""},"class_list":["post-16425","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>K60 Series\uff5c24V Power Supply Inspection &amp; Replacement Guide - LINKO DTF Printer<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.dtflinko.com\/pl\/uslugi-techniczne\/naprawa-techniczna-drukarki\/instrukcja-wymiany-zasilacza-24-v-serii-k60\/\" \/>\n<meta property=\"og:locale\" content=\"pl_PL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"K60 Series\uff5c24V Power Supply Inspection &amp; Replacement Guide - LINKO DTF Printer\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.dtflinko.com\/pl\/uslugi-techniczne\/naprawa-techniczna-drukarki\/instrukcja-wymiany-zasilacza-24-v-serii-k60\/\" \/>\n<meta property=\"og:site_name\" content=\"LINKO DTF Printer\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/linkoprinter\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-11T02:03:36+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/03\/2025-linko-dtf-printer-and-uv-dtf-printer.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1080\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@linkoprinter\" \/>\n<meta name=\"twitter:label1\" content=\"Szacowany czas czytania\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minuty\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/it\\\/servizi-tecnici\\\/riparazione-funzionamento-tecnico-stampante\\\/guida-alla-sostituzione-e-allispezione-dellalimentatore-da-24-v-della-serie-k60\\\/\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/it\\\/servizi-tecnici\\\/riparazione-funzionamento-tecnico-stampante\\\/guida-alla-sostituzione-e-allispezione-dellalimentatore-da-24-v-della-serie-k60\\\/\",\"name\":\"K60 Series\uff5c24V Power Supply Inspection & Replacement Guide - LINKO DTF Printer\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/#website\"},\"datePublished\":\"2025-12-05T01:20:39+00:00\",\"dateModified\":\"2026-04-11T02:03:36+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/it\\\/servizi-tecnici\\\/riparazione-funzionamento-tecnico-stampante\\\/guida-alla-sostituzione-e-allispezione-dellalimentatore-da-24-v-della-serie-k60\\\/#breadcrumb\"},\"inLanguage\":\"pl-PL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.dtflinko.com\\\/it\\\/servizi-tecnici\\\/riparazione-funzionamento-tecnico-stampante\\\/guida-alla-sostituzione-e-allispezione-dellalimentatore-da-24-v-della-serie-k60\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/it\\\/servizi-tecnici\\\/riparazione-funzionamento-tecnico-stampante\\\/guida-alla-sostituzione-e-allispezione-dellalimentatore-da-24-v-della-serie-k60\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Support &#038; Technical Services\",\"item\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/technicke-sluzby\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Printer Technical Operation &amp; Repair\",\"item\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/technicke-sluzby\\\/oprava-technickeho-provozu-tiskarny\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"K60 Series\uff5c24V Power Supply Inspection &#038; Replacement Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/#website\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/\",\"name\":\"LINKO DTF Printer\",\"description\":\"DTF Printer\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pl-PL\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/#organization\",\"name\":\"LINKO\",\"alternateName\":\"LINKO DTF PRINTERS MANUFACTURER\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Linko-logo.png\",\"contentUrl\":\"https:\\\/\\\/www.dtflinko.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Linko-logo.png\",\"width\":1000,\"height\":1000,\"caption\":\"LINKO\"},\"image\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/linkoprinter\",\"https:\\\/\\\/x.com\\\/linkoprinter\",\"https:\\\/\\\/www.youtube.com\\\/@LinkoPrinter\",\"https:\\\/\\\/www.instagram.com\\\/linkoprinter\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/dtflinko\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Seria K60\uff5cPrzewodnik po inspekcji i wymianie zasilacza 24 V \u2014 drukarka LINKO DTF","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.dtflinko.com\/pl\/uslugi-techniczne\/naprawa-techniczna-drukarki\/instrukcja-wymiany-zasilacza-24-v-serii-k60\/","og_locale":"pl_PL","og_type":"article","og_title":"K60 Series\uff5c24V Power Supply Inspection & Replacement Guide - LINKO DTF Printer","og_url":"https:\/\/www.dtflinko.com\/pl\/uslugi-techniczne\/naprawa-techniczna-drukarki\/instrukcja-wymiany-zasilacza-24-v-serii-k60\/","og_site_name":"LINKO DTF Printer","article_publisher":"https:\/\/www.facebook.com\/linkoprinter","article_modified_time":"2026-04-11T02:03:36+00:00","og_image":[{"width":1080,"height":1080,"url":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/03\/2025-linko-dtf-printer-and-uv-dtf-printer.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_site":"@linkoprinter","twitter_misc":{"Szacowany czas czytania":"4 minuty"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.dtflinko.com\/it\/servizi-tecnici\/riparazione-funzionamento-tecnico-stampante\/guida-alla-sostituzione-e-allispezione-dellalimentatore-da-24-v-della-serie-k60\/","url":"https:\/\/www.dtflinko.com\/it\/servizi-tecnici\/riparazione-funzionamento-tecnico-stampante\/guida-alla-sostituzione-e-allispezione-dellalimentatore-da-24-v-della-serie-k60\/","name":"Seria K60\uff5cPrzewodnik po inspekcji i wymianie zasilacza 24 V \u2014 drukarka LINKO DTF","isPartOf":{"@id":"https:\/\/www.dtflinko.com\/cs\/#website"},"datePublished":"2025-12-05T01:20:39+00:00","dateModified":"2026-04-11T02:03:36+00:00","breadcrumb":{"@id":"https:\/\/www.dtflinko.com\/it\/servizi-tecnici\/riparazione-funzionamento-tecnico-stampante\/guida-alla-sostituzione-e-allispezione-dellalimentatore-da-24-v-della-serie-k60\/#breadcrumb"},"inLanguage":"pl-PL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.dtflinko.com\/it\/servizi-tecnici\/riparazione-funzionamento-tecnico-stampante\/guida-alla-sostituzione-e-allispezione-dellalimentatore-da-24-v-della-serie-k60\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.dtflinko.com\/it\/servizi-tecnici\/riparazione-funzionamento-tecnico-stampante\/guida-alla-sostituzione-e-allispezione-dellalimentatore-da-24-v-della-serie-k60\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.dtflinko.com\/cs\/"},{"@type":"ListItem","position":2,"name":"Support &#038; Technical Services","item":"https:\/\/www.dtflinko.com\/cs\/technicke-sluzby\/"},{"@type":"ListItem","position":3,"name":"Printer Technical Operation &amp; Repair","item":"https:\/\/www.dtflinko.com\/cs\/technicke-sluzby\/oprava-technickeho-provozu-tiskarny\/"},{"@type":"ListItem","position":4,"name":"K60 Series\uff5c24V Power Supply Inspection &#038; Replacement Guide"}]},{"@type":"WebSite","@id":"https:\/\/www.dtflinko.com\/cs\/#website","url":"https:\/\/www.dtflinko.com\/cs\/","name":"Drukarka LINKO DTF","description":"Drukarka DTF","publisher":{"@id":"https:\/\/www.dtflinko.com\/cs\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.dtflinko.com\/cs\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pl-PL"},{"@type":"Organization","@id":"https:\/\/www.dtflinko.com\/cs\/#organization","name":"LINKO","alternateName":"LINKO DTF PRINTERS MANUFACTURER","url":"https:\/\/www.dtflinko.com\/cs\/","logo":{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/www.dtflinko.com\/cs\/#\/schema\/logo\/image\/","url":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/09\/Linko-logo.png","contentUrl":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/09\/Linko-logo.png","width":1000,"height":1000,"caption":"LINKO"},"image":{"@id":"https:\/\/www.dtflinko.com\/cs\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/linkoprinter","https:\/\/x.com\/linkoprinter","https:\/\/www.youtube.com\/@LinkoPrinter","https:\/\/www.instagram.com\/linkoprinter\/","https:\/\/www.linkedin.com\/company\/dtflinko\/"]}]}},"_links":{"self":[{"href":"https:\/\/www.dtflinko.com\/pl\/wp-json\/wp\/v2\/pages\/16425","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dtflinko.com\/pl\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.dtflinko.com\/pl\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.dtflinko.com\/pl\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dtflinko.com\/pl\/wp-json\/wp\/v2\/comments?post=16425"}],"version-history":[{"count":10,"href":"https:\/\/www.dtflinko.com\/pl\/wp-json\/wp\/v2\/pages\/16425\/revisions"}],"predecessor-version":[{"id":17865,"href":"https:\/\/www.dtflinko.com\/pl\/wp-json\/wp\/v2\/pages\/16425\/revisions\/17865"}],"up":[{"embeddable":true,"href":"https:\/\/www.dtflinko.com\/pl\/wp-json\/wp\/v2\/pages\/15609"}],"wp:attachment":[{"href":"https:\/\/www.dtflinko.com\/pl\/wp-json\/wp\/v2\/media?parent=16425"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}