{"id":19162,"date":"2026-08-17T13:22:02","date_gmt":"2026-08-17T05:22:02","guid":{"rendered":"https:\/\/www.dtflinko.com\/?page_id=19162"},"modified":"2026-08-17T14:19:20","modified_gmt":"2026-08-17T06:19:20","slug":"panduan-inspeksi-dan-penggantian-catu-daya-24v-km-602","status":"publish","type":"page","link":"https:\/\/www.dtflinko.com\/id\/technical-services\/printer-technical-operation-repair\/km-602-24v-power-supply-inspection-and-replacement-guide\/","title":{"rendered":"Penggantian Catu Daya - KM-602\uff5cCatu Daya 24V"},"content":{"rendered":"<section class=\"section\" id=\"section_1395972504\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row\"  id=\"row-1806951864\">\n\n\t<div id=\"col-187695001\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div id=\"text-3605198347\" class=\"text\">\n\t\t\n<h1 style=\"text-align: center;\">KM-602\uff5cPanduan Inspeksi dan Penggantian Catu Daya 24V<\/h1>\n\t\t\n<style>\n#text-3605198347 {\n  text-align: center;\n}\n<\/style>\n\t<\/div>\n\t\n\t<div id=\"text-3815838969\" class=\"text\">\n\t\t\n<p style=\"text-align: left;\"><strong>Model yang Berlaku:<\/strong> Printer DTF LINKO KM-602<\/p>\n<p style=\"text-align: left;\"><strong>Kapan Menggunakan Panduan Ini:<\/strong> Pompa sirkulasi tinta putih atau motor pengaduk tinta putih tidak berfungsi.<\/p>\n<p style=\"text-align: left;\"><strong>Alat yang Dibutuhkan:<\/strong> Multimeter, obeng Phillips, sarung tangan isolasi.<\/p>\n\t\t\n<style>\n#text-3815838969 {\n  text-align: center;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-645260314\">\n\n\t<div id=\"col-1603736199\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<span class=\"scroll-to\" data-label=\"Scroll to: #1.-printer-power-module-overview\" data-bullet=\"true\" data-link=\"#1.-printer-power-module-overview\" data-title=\"1. Printer Power Module Overview\"><a name=\"1.-printer-power-module-overview\"><\/a><\/span>\n<h2>1. Gambaran Umum Modul Daya Printer<\/h2>\n<p>Printer ini menggunakan beberapa modul daya. Setiap modul daya memasok sistem yang berbeda. Catu Daya 24V adalah catu daya independen untuk sistem tinta putih. Catu daya ini memberikan output DC sebesar 24 V.<\/p>\n<table>\n<thead>\n<tr>\n<th>Modul Daya<\/th>\n<th>Komponen yang Ditenagai<\/th>\n<th>Dokumen Terkait<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Modul Daya Keluaran Ganda<\/td>\n<td>Papan utama, papan kereta, motor sumbu X, motor sumbu Y, papan penggerak layar, kipas pendingin<\/td>\n<td><a href=\"https:\/\/www.dtflinko.com\/id\/layanan-teknis\/perbaikan-operasi-teknis-printer\/panduan-inspeksi-dan-penggantian-modul-daya-keluaran-ganda-km-602\/\">KM-602\uff5cPanduan Inspeksi dan Penggantian Modul Daya Multi-Output<\/a><\/td>\n<\/tr>\n<tr>\n<td>Catu Daya 24V<\/td>\n<td>Pompa sirkulasi tinta putih, motor pengaduk tinta putih<\/td>\n<td>Panduan ini<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/1-Location-Of-The-Power-Modules.webp\" title=\"1-Lokasi-Modul-Daya\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/1-Location-Of-The-Power-Modules-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"1. Lokasi Modul Daya\" ids=\"19159\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/1-Location-Of-The-Power-Modules-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/1-Location-Of-The-Power-Modules-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/1-Location-Of-The-Power-Modules-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/1-Location-Of-The-Power-Modules-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/1-Location-Of-The-Power-Modules-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/1-Location-Of-The-Power-Modules-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/1-Location-Of-The-Power-Modules.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>1-Lokasi-Modul-Daya<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1286992928\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>1.1 Modul Daya Independen Lainnya (Tidak Dibahas dalam Panduan Ini)<\/h3>\n<p>Panduan ini hanya berlaku untuk Catu Daya 24V. Modul Daya Multi-Output memasok daya ke papan utama, papan kereta, motor sumbu X, motor sumbu Y, papan penggerak layar, dan kipas pendingin. Untuk Modul Daya Multi-Output, lihat <a href=\"https:\/\/www.dtflinko.com\/id\/layanan-teknis\/perbaikan-operasi-teknis-printer\/panduan-inspeksi-dan-penggantian-modul-daya-keluaran-ganda-km-602\/\">KM-602\uff5cPanduan Inspeksi dan Penggantian Modul Daya Multi-Output.<\/a><\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-2051516197\">\n\n\t<div id=\"col-1328507157\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<span class=\"scroll-to\" data-label=\"Scroll to: #2.-24v-power-supply-wiring-diagram\" data-bullet=\"true\" data-link=\"#2.-24v-power-supply-wiring-diagram\" data-title=\"2. 24V Power Supply Wiring Diagram\"><a name=\"2.-24v-power-supply-wiring-diagram\"><\/a><\/span>\n<h2>2. Diagram Pengkabelan Catu Daya 24V<\/h2>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/2-24V-Power-Supply-Wiring-Diagram.webp\" title=\"Diagram Pengkabelan Catu Daya 2-24V\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/2-24V-Power-Supply-Wiring-Diagram-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Diagram Pengkabelan Catu Daya 2-24V\" ids=\"19160\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/2-24V-Power-Supply-Wiring-Diagram-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/2-24V-Power-Supply-Wiring-Diagram-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/2-24V-Power-Supply-Wiring-Diagram-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/2-24V-Power-Supply-Wiring-Diagram-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/2-24V-Power-Supply-Wiring-Diagram-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/2-24V-Power-Supply-Wiring-Diagram-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/2-24V-Power-Supply-Wiring-Diagram.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>Diagram Pengkabelan Catu Daya 2-24V<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<table>\n<thead>\n<tr>\n<th>Kategori<\/th>\n<th>Tidak.<\/th>\n<th>Terminal<\/th>\n<th>Deskripsi<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Input AC<br \/>(daya AC eksternal \u2192 Catu Daya 24V)<\/td>\n<td>1<\/td>\n<td>Langsung (Kiri)<\/td>\n<td>Input daya AC<\/td>\n<\/tr>\n<tr>\n<td> <\/td>\n<td>2<\/td>\n<td>Netral (N)<\/td>\n<td>Jalur balik AC<\/td>\n<\/tr>\n<tr>\n<td> <\/td>\n<td>3<\/td>\n<td>Tanah (G)<\/td>\n<td>Perlindungan antistatik dan keselamatan<\/td>\n<\/tr>\n<tr>\n<td>Keluaran DC<br \/>(Sumber Daya 24V \u2192 pompa\/motor)<\/td>\n<td>4<\/td>\n<td>24 V negatif<\/td>\n<td>Keluaran ke pompa sirkulasi tinta putih dan motor pengaduk (\u2013)<\/td>\n<\/tr>\n<tr>\n<td> <\/td>\n<td>\u2464<\/td>\n<td>24 V positif<\/td>\n<td>Keluaran ke pompa sirkulasi tinta putih dan motor pengaduk (+)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Dalam panduan ini, \u2460\u2013\u2464 selalu mengacu pada angka-angka di Gambar 2.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1412345313\">\n\n\t<div id=\"col-499379106\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<span class=\"scroll-to\" data-label=\"Scroll to: #3.-fault-inspection-procedure-(check-ac-first,-then-dc)\" data-bullet=\"true\" data-link=\"#3.-fault-inspection-procedure-(check-ac-first,-then-dc)\" data-title=\"3. Fault Inspection Procedure (Check AC First, Then DC)\"><a name=\"3.-fault-inspection-procedure-(check-ac-first,-then-dc)\"><\/a><\/span>\n<h2>3. Prosedur Pemeriksaan Kerusakan (Periksa AC Terlebih Dahulu, Kemudian DC)<\/h2>\n<p><strong>\u26a0 Penting:<\/strong> Jika input AC eksternal (\u2460\u2461) tidak memiliki daya, output DC dari catu daya 24V (\u2463\u2464) menunjukkan 0 V. Pembacaan ini normal. Pembacaan ini tidak berarti bahwa catu daya 24V telah rusak. Selalu periksa input AC terlebih dahulu. Kemudian periksa output DC setelahnya.<\/p>\n<h3>3.1 Instruksi Keselamatan<\/h3>\n<ul>\n<li>Ukur tegangan saat printer dalam keadaan menyala.<\/li>\n<li>Putuskan semua aliran listrik sebelum Anda mengganti catu daya 24V.<\/li>\n<li>Tunggu 1 menit setelah Anda mencabut kabel daya. Kemudian mulailah melepaskan kabel-kabelnya.<\/li>\n<li>Gunakan sarung tangan berinsulasi. Jangan menyentuh sirkuit terbuka dengan tangan Anda.<\/li>\n<\/ul>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.1-Turning-On-The-MAIN-POWER-Switch.webp\" title=\"3.1-Menghidupkan-Saklar-DAYA-UTAMA\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.1-Turning-On-The-MAIN-POWER-Switch-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"3.1 Menghidupkan Saklar DAYA UTAMA\" ids=\"19161\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.1-Turning-On-The-MAIN-POWER-Switch-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.1-Turning-On-The-MAIN-POWER-Switch-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.1-Turning-On-The-MAIN-POWER-Switch-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.1-Turning-On-The-MAIN-POWER-Switch-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.1-Turning-On-The-MAIN-POWER-Switch-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.1-Turning-On-The-MAIN-POWER-Switch-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.1-Turning-On-The-MAIN-POWER-Switch.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.1-Menghidupkan-Saklar-DAYA-UTAMA<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-657583688\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>3.2 Pemeriksaan Input AC (\u2460\u2013\u2461)<\/h3>\n<p>Mode multimeter: ACV 600 V. Pada multimeter dengan fitur auto-ranging, pilih ACV.<\/p>\n<p>Metode pengukuran:<\/p>\n<ul>\n<li>Probe merah \u2192 \u2460 aktif<\/li>\n<li>Probe hitam \u2192 \u2461 netral<\/li>\n<\/ul>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.2-Measuring-The-AC-Input-Of-The-24V-Power-Supply.webp\" title=\"3.2-Mengukur-Input-AC-Dari-Sumber-Daya-24V\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.2-Measuring-The-AC-Input-Of-The-24V-Power-Supply-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"3.2 Mengukur Input AC dari Catu Daya 24V\" ids=\"19143\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.2-Measuring-The-AC-Input-Of-The-24V-Power-Supply-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.2-Measuring-The-AC-Input-Of-The-24V-Power-Supply-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.2-Measuring-The-AC-Input-Of-The-24V-Power-Supply-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.2-Measuring-The-AC-Input-Of-The-24V-Power-Supply-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.2-Measuring-The-AC-Input-Of-The-24V-Power-Supply-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.2-Measuring-The-AC-Input-Of-The-24V-Power-Supply-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.2-Measuring-The-AC-Input-Of-The-24V-Power-Supply.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.2-Mengukur-Input-AC-Dari-Sumber-Daya-24V<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p><strong>Nilai normal: AC 200\u2013240 V<\/strong><\/p>\n<p>Catu daya 24V menerima daya AC. Lanjutkan ke langkah 3.3 dan periksa output DC.<\/p>\n<p><strong>Nilai abnormal: 0 V, atau pembacaan tidak stabil<\/strong><\/p>\n<p>Ini bukan kerusakan pada catu daya 24V. Periksa item-item berikut sesuai urutan yang diberikan:<\/p>\n<ol>\n<li>Tidak ada aliran listrik di stopkontak dinding.<\/li>\n<li>SAKLAR PROTEKSI terputus<\/li>\n<li>Saklar DAYA UTAMA tidak dinyalakan<\/li>\n<li>Saklar daya atas tidak dinyalakan<\/li>\n<li>Kabel AC yang longgar<\/li>\n<li>Terminal yang longgar atau teroksidasi<\/li>\n<li>Kabel AC yang rusak<\/li>\n<\/ol>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1081351995\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>3.3 Pemeriksaan Output DC Catu Daya 24V (\u2463\u2013\u2464)<\/h3>\n<p><strong>Modus multimeter:<\/strong> DCV 200 V. Pada multimeter dengan fitur auto-ranging, pilih DCV.<\/p>\n<p><strong>Metode pengukuran:<\/strong><\/p>\n<ul>\n<li>Probe hitam \u2192 \u2463 24 V negatif<\/li>\n<li>Probe merah \u2192 \u2464 24 V positif<\/li>\n<\/ul>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply.webp\" title=\"3.3-Mengukur-Output-DC-Dari-Sumber-Daya-24V\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"3.3-1 Mengukur Keluaran DC dari Catu Daya 24V\" ids=\"19144\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.3-Mengukur-Output-DC-Dari-Sumber-Daya-24V<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-2126361947\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h4>3.3.1 Evaluasi dan Tindakan Keluaran DC<\/h4>\n<table>\n<thead>\n<tr>\n<th>Hasil Pengukuran<\/th>\n<th>Pompa \/ Motor<\/th>\n<th>Status<\/th>\n<th>Tindakan<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>23 \u2013 25 V<\/td>\n<td>Berjalan normal<\/td>\n<td>Catu daya 24V dan jalur catu daya dalam kondisi normal.<\/td>\n<td>Kesalahan bukan terletak pada jalur catu daya 24 V. Tugas dalam panduan ini telah selesai. (Lihat Gambar 3.3-2)<\/td>\n<\/tr>\n<tr>\n<td>23 \u2013 25 V<\/td>\n<td>Tidak berfungsi<\/td>\n<td>Catu daya 24V normal. Kerusakan terletak pada rangkaian hilir.<\/td>\n<td>Lanjutkan ke 3.3.2. (Lihat Gambar 3.3-2)<\/td>\n<\/tr>\n<tr>\n<td>Input AC normal, dan pembacaannya 0 V atau di bawah 23 V.<\/td>\n<td>Tidak berfungsi<\/td>\n<td>Catu daya 24V mengalami kerusakan internal.<\/td>\n<td>Ganti catu daya 24V. Lanjutkan ke Bagian 4. (Lihat Gambar 3.3-3)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-2-Normal-DC-Output-Of-The-24V-Power-Supply.webp\" title=\"3.3-2-Output-DC-Normal-Dari-Sumber-Daya-24V\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-2-Normal-DC-Output-Of-The-24V-Power-Supply-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"3.3-2 Keluaran DC Normal dari Catu Daya 24V\" ids=\"19165,19146\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-2-Normal-DC-Output-Of-The-24V-Power-Supply-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-2-Normal-DC-Output-Of-The-24V-Power-Supply-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-2-Normal-DC-Output-Of-The-24V-Power-Supply-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-2-Normal-DC-Output-Of-The-24V-Power-Supply-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-2-Normal-DC-Output-Of-The-24V-Power-Supply-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-2-Normal-DC-Output-Of-The-24V-Power-Supply-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-2-Normal-DC-Output-Of-The-24V-Power-Supply.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.3-2-Output-DC-Normal-Dari-Sumber-Daya-24V<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-3-Abnormal-DC-Output-Of-The-24V-Power-Supply.webp\" title=\"3.3-3-Output-DC-Abnormal-Dari-Sumber-Daya-24V\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-3-Abnormal-DC-Output-Of-The-24V-Power-Supply-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"3.3-3 Keluaran DC Abnormal dari Catu Daya 24V\" ids=\"19165,19146\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-3-Abnormal-DC-Output-Of-The-24V-Power-Supply-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-3-Abnormal-DC-Output-Of-The-24V-Power-Supply-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-3-Abnormal-DC-Output-Of-The-24V-Power-Supply-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-3-Abnormal-DC-Output-Of-The-24V-Power-Supply-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-3-Abnormal-DC-Output-Of-The-24V-Power-Supply-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-3-Abnormal-DC-Output-Of-The-24V-Power-Supply-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-3-Abnormal-DC-Output-Of-The-24V-Power-Supply.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.3-3-Output-DC-Abnormal-Dari-Sumber-Daya-24V<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1811359199\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h4>3.3.2 Pemeriksaan Tegangan Masukan pada Pompa Sirkulasi Tinta Putih \/ Motor Pengaduk Tinta Putih<\/h4>\n<p><strong>Modus multimeter:<\/strong> DCV 200 V. Pada multimeter dengan fitur auto-ranging, pilih DCV.<\/p>\n<p><strong>Metode pengukuran:<\/strong><\/p>\n<ul>\n<li>Probe hitam \u2192 terminal input negatif pompa atau motor pengaduk<\/li>\n<li>Probe merah \u2192 terminal input positif pompa atau motor pengaduk<\/li>\n<\/ul>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-4-Measuring-The-Input-Voltage-At-The-Pump-And-Motor.webp\" title=\"3.3-4-Mengukur-Tegangan-Masukan-Pada-Pompa-Dan-Motor\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-4-Measuring-The-Input-Voltage-At-The-Pump-And-Motor-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"3.3-4 Mengukur Tegangan Masukan pada Pompa dan Motor\" ids=\"19147\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-4-Measuring-The-Input-Voltage-At-The-Pump-And-Motor-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-4-Measuring-The-Input-Voltage-At-The-Pump-And-Motor-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-4-Measuring-The-Input-Voltage-At-The-Pump-And-Motor-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-4-Measuring-The-Input-Voltage-At-The-Pump-And-Motor-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-4-Measuring-The-Input-Voltage-At-The-Pump-And-Motor-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-4-Measuring-The-Input-Voltage-At-The-Pump-And-Motor-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-4-Measuring-The-Input-Voltage-At-The-Pump-And-Motor.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.3-4-Mengukur-Tegangan-Masukan-Pada-Pompa-Dan-Motor<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<table>\n<thead>\n<tr>\n<th>Tegangan Masukan<\/th>\n<th>Status<\/th>\n<th>Tindakan<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>0,0 V<\/td>\n<td>Arus listrik tidak sampai ke pompa atau motor pengaduk. Kabel putus, atau kontak mengalami oksidasi.<\/td>\n<td>Periksa kabelnya. Ganti kabelnya.<\/td>\n<\/tr>\n<tr>\n<td>Tegangan 23 \u2013 25 V, dan pompa atau motor pengaduk tidak berfungsi.<\/td>\n<td>Pompa atau motor pengaduknya rusak.<\/td>\n<td>Ganti pompa atau motor pengaduknya.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Jangan mengganti catu daya 24V jika kerusakannya ada pada kabel, atau pada pompa, atau pada motor pengaduk. Tugas dalam panduan ini telah selesai.<\/strong><\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-304567064\">\n\n\t<div id=\"col-1679393115\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<span class=\"scroll-to\" data-label=\"Scroll to: #4.-24v-power-supply-replacement\" data-bullet=\"true\" data-link=\"#4.-24v-power-supply-replacement\" data-title=\"4. 24V Power Supply Replacement\"><a name=\"4.-24v-power-supply-replacement\"><\/a><\/span>\n<h2>4. Penggantian Catu Daya 24V<\/h2>\n<p><strong>Prasyarat:<\/strong> Lakukan bagian ini hanya setelah 3.3.1 menunjukkan bahwa Catu Daya 24V mengalami kerusakan internal.<\/p>\n<h3>4.1 Mematikan Daya<\/h3>\n<ol>\n<li>Tekan sakelar daya bagian atas untuk mematikan printer. (Lihat Gambar 4.1-1)<\/li>\n<li>Matikan sakelar DAYA UTAMA di bagian belakang printer. (Lihat Gambar 4.1-2)<\/li>\n<li>Cabut kabel daya.<\/li>\n<li>Tunggu 1 menit. Kemudian mulailah mencabut kabel-kabelnya.<\/li>\n<\/ol>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-1-Top-Power-Switch-Of-The-Printer.webp\" title=\"4.1-1-Tombol-Daya-Atas-Printer\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-1-Top-Power-Switch-Of-The-Printer-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"4.1-1 Tombol Daya Atas Printer\" ids=\"19148,19149\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-1-Top-Power-Switch-Of-The-Printer-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-1-Top-Power-Switch-Of-The-Printer-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-1-Top-Power-Switch-Of-The-Printer-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-1-Top-Power-Switch-Of-The-Printer-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-1-Top-Power-Switch-Of-The-Printer-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-1-Top-Power-Switch-Of-The-Printer-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-1-Top-Power-Switch-Of-The-Printer.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.1-1-Tombol-Daya-Atas-Printer<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-2-Turning-Off-The-MAIN-POWER-Switch.webp\" title=\"4.1-2-Mematikan-Saklar-DAYA-UTAMA\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-2-Turning-Off-The-MAIN-POWER-Switch-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"4.1-2 Mematikan Saklar DAYA UTAMA\" ids=\"19148,19149\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-2-Turning-Off-The-MAIN-POWER-Switch-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-2-Turning-Off-The-MAIN-POWER-Switch-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-2-Turning-Off-The-MAIN-POWER-Switch-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-2-Turning-Off-The-MAIN-POWER-Switch-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-2-Turning-Off-The-MAIN-POWER-Switch-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-2-Turning-Off-The-MAIN-POWER-Switch-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-2-Turning-Off-The-MAIN-POWER-Switch.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.1-2-Mematikan-Saklar-DAYA-UTAMA<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-2074168206\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>4.2 Lepaskan Catu Daya 24V Lama<\/h3>\n<h4>4.2.1 Melepas Panel Belakang<\/h4>\n<ol>\n<li>Congkel perlahan penutup plastik putih di kedua sisi panel belakang.<\/li>\n<li>Cabut kabel jaringan. (Lihat Gambar 4.2-1)<\/li>\n<li>Lepaskan sekrup panel belakang. (Lihat Gambar 4.2-2)<\/li>\n<li>Lepaskan kabel kipas pendingin. Lepaskan panel belakang. (Lihat Gambar 4.2-3)<\/li>\n<\/ol>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-1-Removing-The-Plastic-Cover-Plugs-And-The-Network-Cable.webp\" title=\"4.2-1-Melepas-Penutup-Plastik-Steker-Dan-Kabel-Jaringan\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-1-Removing-The-Plastic-Cover-Plugs-And-The-Network-Cable-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"4.2-1 Melepas Penutup Plastik, Steker, dan Kabel Jaringan\" ids=\"19150,19151,19152\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-1-Removing-The-Plastic-Cover-Plugs-And-The-Network-Cable-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-1-Removing-The-Plastic-Cover-Plugs-And-The-Network-Cable-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-1-Removing-The-Plastic-Cover-Plugs-And-The-Network-Cable-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-1-Removing-The-Plastic-Cover-Plugs-And-The-Network-Cable-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-1-Removing-The-Plastic-Cover-Plugs-And-The-Network-Cable-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-1-Removing-The-Plastic-Cover-Plugs-And-The-Network-Cable-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-1-Removing-The-Plastic-Cover-Plugs-And-The-Network-Cable.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.2-1-Melepas-Penutup-Plastik-Steker-Dan-Kabel-Jaringan<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-2-Removing-The-Screws-Of-The-Back-Panel.webp\" title=\"4.2-2-Melepas-Sekrup-Panel-Belakang\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-2-Removing-The-Screws-Of-The-Back-Panel-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"4.2-2 Melepas Sekrup Panel Belakang\" ids=\"19150,19151,19152\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-2-Removing-The-Screws-Of-The-Back-Panel-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-2-Removing-The-Screws-Of-The-Back-Panel-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-2-Removing-The-Screws-Of-The-Back-Panel-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-2-Removing-The-Screws-Of-The-Back-Panel-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-2-Removing-The-Screws-Of-The-Back-Panel-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-2-Removing-The-Screws-Of-The-Back-Panel-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-2-Removing-The-Screws-Of-The-Back-Panel.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.2-2-Melepas-Sekrup-Panel-Belakang<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-3-Disconnecting-The-Cooling-Fan-Cable.webp\" title=\"4.2-3-Melepaskan-Kabel-Kipas-Pendingin\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-3-Disconnecting-The-Cooling-Fan-Cable-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"4.2-3 Melepaskan Kabel Kipas Pendingin\" ids=\"19150,19151,19152\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-3-Disconnecting-The-Cooling-Fan-Cable-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-3-Disconnecting-The-Cooling-Fan-Cable-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-3-Disconnecting-The-Cooling-Fan-Cable-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-3-Disconnecting-The-Cooling-Fan-Cable-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-3-Disconnecting-The-Cooling-Fan-Cable-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-3-Disconnecting-The-Cooling-Fan-Cable-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-3-Disconnecting-The-Cooling-Fan-Cable.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.2-3-Melepaskan-Kabel-Kipas-Pendingin<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-626932448\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h4>4.2.2 Lepaskan Kabel<\/h4>\n<ol>\n<li>Ambil foto susunan kabel saat setiap kabel masih terhubung. Gunakan foto tersebut untuk menyambungkan kembali setiap kabel dengan benar. (Lihat Gambar 4.2-4)<\/li>\n<li>Kendurkan sekrup terminal \u2460\u2013\u2464 secara berurutan. Ikuti Gambar 2.<\/li>\n<li>Cabut kabel-kabelnya satu per satu.<\/li>\n<\/ol>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-4-Wiring-Record-Of-The-24V-Power-Supply.webp\" title=\"4.2-4-Catatan-Pengkabelan-Catu-Daya-24V\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-4-Wiring-Record-Of-The-24V-Power-Supply-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"4.2-4 Catatan Pengkabelan Catu Daya 24V\" ids=\"19153\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-4-Wiring-Record-Of-The-24V-Power-Supply-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-4-Wiring-Record-Of-The-24V-Power-Supply-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-4-Wiring-Record-Of-The-24V-Power-Supply-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-4-Wiring-Record-Of-The-24V-Power-Supply-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-4-Wiring-Record-Of-The-24V-Power-Supply-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-4-Wiring-Record-Of-The-24V-Power-Supply-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-4-Wiring-Record-Of-The-24V-Power-Supply.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.2-4-Catatan-Pengkabelan-Catu-Daya-24V<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-834499913\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h4>4.2.3 Lepaskan Sekrup Pengikat<\/h4>\n<ol>\n<li>Lepaskan sekrup pengikat \u2460.<\/li>\n<li>Kendurkan sekrup pengunci \u2461. Lihat Gambar 4.2-5.<\/li>\n<li>Lepaskan catu daya 24V lama. Lihat Gambar 4.2-6.<\/li>\n<\/ol>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-5-Removing-The-Fixing-Screw-And-Locating-Screw.webp\" title=\"4.2-5-Melepas-Sekrup-Pengikat-dan-Menemukan-Sekrup\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-5-Removing-The-Fixing-Screw-And-Locating-Screw-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"4.2-5 Melepas Sekrup Pengikat dan Sekrup Penentu Posisi\" ids=\"19154,19155\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-5-Removing-The-Fixing-Screw-And-Locating-Screw-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-5-Removing-The-Fixing-Screw-And-Locating-Screw-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-5-Removing-The-Fixing-Screw-And-Locating-Screw-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-5-Removing-The-Fixing-Screw-And-Locating-Screw-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-5-Removing-The-Fixing-Screw-And-Locating-Screw-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-5-Removing-The-Fixing-Screw-And-Locating-Screw-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-5-Removing-The-Fixing-Screw-And-Locating-Screw.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.2-5-Melepas-Sekrup-Pengikat-dan-Menemukan-Sekrup<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-6-The-Removed-24V-Power-Supply.webp\" title=\"4.2-6-Catu Daya 24V yang Dilepas\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-6-The-Removed-24V-Power-Supply-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"4.2-6 Catu Daya 24V yang Dilepas\" ids=\"19154,19155\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-6-The-Removed-24V-Power-Supply-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-6-The-Removed-24V-Power-Supply-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-6-The-Removed-24V-Power-Supply-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-6-The-Removed-24V-Power-Supply-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-6-The-Removed-24V-Power-Supply-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-6-The-Removed-24V-Power-Supply-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-6-The-Removed-24V-Power-Supply.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.2-6-Catu Daya 24V yang Dilepas<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-141642333\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>4.3 Pasang Catu Daya 24V yang Baru<\/h3>\n<h4>4.3.1 Konfirmasi Model<\/h4>\n<p>Bandingkan label model pada catu daya 24V yang baru dan yang lama. Pastikan kedua model tersebut sama.<\/p>\n<h4>4.3.2 Memasang Catu Daya 24V<\/h4>\n<ol>\n<li>Sejajarkan lubang pemasangan. Pasang catu daya 24V ke posisi sekrup pengencang.<\/li>\n<li>Kencangkan sekrup pengikat dan sekrup penentu posisi. (Lihat Gambar 4.2-5)<\/li>\n<\/ol>\n<h4>4.3.3 Menghubungkan Kabel<\/h4>\n<ol>\n<li>Hubungkan kabel \u2460\u2013\u2464 secara berurutan. Ikuti Gambar 2.<\/li>\n<li>Pastikan setiap kabel terpasang sepenuhnya pada tempatnya.<\/li>\n<li>Bandingkan susunan kabel dengan foto dari 4.2.2. Pastikan setiap kabel berada pada posisi yang benar. Pastikan tidak ada kabel yang kendur.<\/li>\n<li>Kencangkan semua sekrup terminal.<\/li>\n<\/ol>\n<h4>4.3.4 Pasang Kembali Panel Belakang<\/h4>\n<ol>\n<li>Hubungkan kabel kipas pendingin. (Lihat Gambar 4.2-3)<\/li>\n<li>Sejajarkan panel belakang. Pasang panel belakang. Kencangkan sekrup. (Lihat Gambar 4.2-2)<\/li>\n<li>Colokkan kabel jaringan. (Lihat Gambar 4.2-1)<\/li>\n<li>Pasang penutup plastik putih di kedua sisi.<\/li>\n<\/ol>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-57732477\">\n\n\t<div id=\"col-242065192\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<span class=\"scroll-to\" data-label=\"Scroll to: #5.-power-on-check\" data-bullet=\"true\" data-link=\"#5.-power-on-check\" data-title=\"5. Power-On Check\"><a name=\"5.-power-on-check\"><\/a><\/span>\n<h2>5. Pemeriksaan Saat Dinyalakan<\/h2>\n<h3>5.1 Periksa kembali semua kabel untuk memastikan tidak ada sambungan yang longgar dan sambungan yang terbalik.<\/h3>\n<h3>5.2 Sambungkan kabel daya. Hidupkan sakelar DAYA UTAMA di bagian belakang printer. (Lihat Gambar 3.1)<\/h3>\n<h3>5.3 Tekan sakelar daya bagian atas. Lampu indikator menyala. (Lihat Gambar 5.3)<\/h3>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.3-Pressing-The-Top-Power-Switch-Top-View.webp\" title=\"5.3-Menekan-Tombol-Daya-Atas-Tampilan-Atas\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.3-Pressing-The-Top-Power-Switch-Top-View-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"5.3 Menekan Tombol Daya Atas (Tampilan Atas)\" ids=\"19156\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.3-Pressing-The-Top-Power-Switch-Top-View-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.3-Pressing-The-Top-Power-Switch-Top-View-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.3-Pressing-The-Top-Power-Switch-Top-View-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.3-Pressing-The-Top-Power-Switch-Top-View-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.3-Pressing-The-Top-Power-Switch-Top-View-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.3-Pressing-The-Top-Power-Switch-Top-View-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.3-Pressing-The-Top-Power-Switch-Top-View.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>5.3-Menekan-Tombol-Daya-Atas-Tampilan-Atas<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<h3>5.4 Konfirmasi Status Akhir<\/h3>\n<p>Setelah semua kabel terhubung dan printer dinyalakan, pastikan tiga hal berikut:<\/p>\n<ol>\n<li>Lampu indikator catu daya 24V tetap menyala.<\/li>\n<li>Pembacaan pada \u2463\u2013\u2464 adalah 23\u201325V. Gunakan multimeter dalam mode DCV 200 V.<\/li>\n<li>Pompa sirkulasi tinta putih dan motor pengaduk tinta putih kembali beroperasi.<\/li>\n<\/ol>\n<p><strong>\u2705 Biasa:<\/strong> Ketiga persyaratan tersebut terpenuhi. Penggantian telah selesai. (Lihat Gambar 5.4-1)<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1955843540\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-1-Normal-Status-After-Replacement.webp\" title=\"5.4-1-Status-Normal-Setelah-Penggantian\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-1-Normal-Status-After-Replacement-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"5.4-1 Status Normal Setelah Penggantian\" ids=\"19157\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-1-Normal-Status-After-Replacement-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-1-Normal-Status-After-Replacement-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-1-Normal-Status-After-Replacement-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-1-Normal-Status-After-Replacement-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-1-Normal-Status-After-Replacement-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-1-Normal-Status-After-Replacement-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-1-Normal-Status-After-Replacement.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>5.4-1-Status-Normal-Setelah-Penggantian<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p><strong><b>\u274c <\/b><\/strong><strong><b>\u00a0<\/b>Abnormal:<\/strong> Lampu indikator mati, atau lampu indikator berkedip tidak normal, atau pembacaannya 0,0 V. (Lihat Gambar 5.4-2)<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-2-Abnormal-Status-After-Replacement.webp\" title=\"5.4-2-Status-Abnormal-Setelah-Penggantian\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-2-Abnormal-Status-After-Replacement-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"5.4-2 Status Abnormal Setelah Penggantian\" ids=\"19158\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-2-Abnormal-Status-After-Replacement-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-2-Abnormal-Status-After-Replacement-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-2-Abnormal-Status-After-Replacement-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-2-Abnormal-Status-After-Replacement-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-2-Abnormal-Status-After-Replacement-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-2-Abnormal-Status-After-Replacement-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-2-Abnormal-Status-After-Replacement.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>5.4-2-Status-Abnormal-Setelah-Penggantian<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>Periksa kembali sambungan kabelnya. Jika sambungan kabel sudah benar tetapi pembacaan masih abnormal, hubungi dukungan teknis LINKO.<\/p>\n<p><strong>\u26a0 Tegangan normal, tetapi pompa atau motor pengaduk tetap tidak berfungsi:<\/strong> Kesalahan bukan terletak pada catu daya 24V. Kembali ke 3.3.2 dan ukur tegangan input pada pompa dan motor pengaduk.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-2028216758\">\n\n\t<div id=\"col-1680531707\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<div class=\"is-divider divider clearfix\" style=\"max-width:1200px;height:2px;\"><\/div>\n<p><span style=\"font-size: 115%;\"><strong>Dukungan Teknis LINKO<\/strong><\/span><br \/><span style=\"font-size: 95%;\"><span style=\"color: #4f4f4f;\"><span style=\"color: #333333;\">Email:<\/span> <\/span><a href=\"mailto:support@dtflinko.com\">support@dtflinko.com<\/a><\/span><br \/><span style=\"font-size: 95%;\"><span style=\"color: #4f4f4f;\"><span style=\"color: #333333;\">Situs web:<\/span> <\/span><a href=\"https:\/\/www.dtflinko.com\/id\/\">www.dtflinko.com<\/a><\/span><\/p>\n<p><span style=\"font-size: 85%; color: #808080;\">\u00a9 2026 Tim Teknis LINKO. Semua hak dilindungi undang-undang.<\/span><br \/><span style=\"font-size: 85%; color: #808080;\">Dilarang memperbanyak atau mengubah dokumen ini tanpa izin.<\/span><\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1395972504 {\n  padding-top: 40px;\n  padding-bottom: 40px;\n}\n@media (min-width:850px) {\n  #section_1395972504 {\n    padding-top: 60px;\n    padding-bottom: 60px;\n  }\n}\n<\/style>\n\t<\/section>","protected":false},"excerpt":{"rendered":"","protected":false},"author":3,"featured_media":19144,"parent":15609,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-blank.php","meta":{"footnotes":""},"class_list":["post-19162","page","type-page","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>KM-602 24V Power Supply Inspection and Replacement Guide | LINKO DTF Printer<\/title>\n<meta name=\"description\" content=\"Test the AC input and the DC output of the 24V power supply on the LINKO KM-602 DTF printer, then replace the 24V Power Supply when the white ink pump or white ink circulation pumpstops working.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.dtflinko.com\/id\/layanan-teknis\/perbaikan-operasi-teknis-printer\/panduan-inspeksi-dan-penggantian-catu-daya-24v-km-602\/\" \/>\n<meta property=\"og:locale\" content=\"id_ID\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"KM-602 24V Power Supply Inspection and Replacement Guide | LINKO DTF Printer\" \/>\n<meta property=\"og:description\" content=\"Test the AC input and the DC output of the 24V power supply on the LINKO KM-602 DTF printer, then replace the 24V Power Supply when the white ink pump or white ink circulation pumpstops working.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.dtflinko.com\/id\/layanan-teknis\/perbaikan-operasi-teknis-printer\/panduan-inspeksi-dan-penggantian-catu-daya-24v-km-602\/\" \/>\n<meta property=\"og:site_name\" content=\"LINKO DTF Printer\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/linkoprinter\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-17T06:19:20+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"960\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@linkoprinter\" \/>\n<meta name=\"twitter:label1\" content=\"Estimasi waktu membaca\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 menit\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/km-602-24v-power-supply-inspection-and-replacement-guide\\\/\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/km-602-24v-power-supply-inspection-and-replacement-guide\\\/\",\"name\":\"KM-602 24V Power Supply Inspection and Replacement Guide | LINKO DTF Printer\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/km-602-24v-power-supply-inspection-and-replacement-guide\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/km-602-24v-power-supply-inspection-and-replacement-guide\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.dtflinko.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply.webp\",\"datePublished\":\"2026-08-17T05:22:02+00:00\",\"dateModified\":\"2026-08-17T06:19:20+00:00\",\"description\":\"Test the AC input and the DC output of the 24V power supply on the LINKO KM-602 DTF printer, then replace the 24V Power Supply when the white ink pump or white ink circulation pumpstops working.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/km-602-24v-power-supply-inspection-and-replacement-guide\\\/#breadcrumb\"},\"inLanguage\":\"id\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/km-602-24v-power-supply-inspection-and-replacement-guide\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/km-602-24v-power-supply-inspection-and-replacement-guide\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply.webp\",\"contentUrl\":\"https:\\\/\\\/www.dtflinko.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply.webp\",\"width\":1280,\"height\":960,\"caption\":\"3.3-Measuring-The-DC-Output-Of-The-24V-Power-Supply\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/km-602-24v-power-supply-inspection-and-replacement-guide\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.dtflinko.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Support &#038; Technical Services\",\"item\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Printer Technical Operation &amp; Repair\",\"item\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Replace Power Supply- KM-602\uff5c24V Power Supply\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/#website\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/\",\"name\":\"LINKO DTF Printer\",\"description\":\"DTF Printer\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.dtflinko.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"id\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/#organization\",\"name\":\"LINKO\",\"alternateName\":\"LINKO DTF PRINTERS MANUFACTURER\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Linko-logo.png\",\"contentUrl\":\"https:\\\/\\\/www.dtflinko.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Linko-logo.png\",\"width\":1000,\"height\":1000,\"caption\":\"LINKO\"},\"image\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/linkoprinter\",\"https:\\\/\\\/x.com\\\/linkoprinter\",\"https:\\\/\\\/www.youtube.com\\\/@LinkoPrinter\",\"https:\\\/\\\/www.instagram.com\\\/linkoprinter\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/dtflinko\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Panduan Inspeksi dan Penggantian Catu Daya KM-602 24V | Printer DTF LINKO","description":"Periksa input AC dan output DC dari catu daya 24V pada printer LINKO KM-602 DTF, kemudian ganti catu daya 24V jika pompa tinta putih atau pompa sirkulasi tinta putih berhenti bekerja.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.dtflinko.com\/id\/layanan-teknis\/perbaikan-operasi-teknis-printer\/panduan-inspeksi-dan-penggantian-catu-daya-24v-km-602\/","og_locale":"id_ID","og_type":"article","og_title":"KM-602 24V Power Supply Inspection and Replacement Guide | LINKO DTF Printer","og_description":"Test the AC input and the DC output of the 24V power supply on the LINKO KM-602 DTF printer, then replace the 24V Power Supply when the white ink pump or white ink circulation pumpstops working.","og_url":"https:\/\/www.dtflinko.com\/id\/layanan-teknis\/perbaikan-operasi-teknis-printer\/panduan-inspeksi-dan-penggantian-catu-daya-24v-km-602\/","og_site_name":"LINKO DTF Printer","article_publisher":"https:\/\/www.facebook.com\/linkoprinter","article_modified_time":"2026-08-17T06:19:20+00:00","og_image":[{"width":1280,"height":960,"url":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_site":"@linkoprinter","twitter_misc":{"Estimasi waktu membaca":"1 menit"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/km-602-24v-power-supply-inspection-and-replacement-guide\/","url":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/km-602-24v-power-supply-inspection-and-replacement-guide\/","name":"Panduan Inspeksi dan Penggantian Catu Daya KM-602 24V | Printer DTF LINKO","isPartOf":{"@id":"https:\/\/www.dtflinko.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/km-602-24v-power-supply-inspection-and-replacement-guide\/#primaryimage"},"image":{"@id":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/km-602-24v-power-supply-inspection-and-replacement-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply.webp","datePublished":"2026-08-17T05:22:02+00:00","dateModified":"2026-08-17T06:19:20+00:00","description":"Periksa input AC dan output DC dari catu daya 24V pada printer LINKO KM-602 DTF, kemudian ganti catu daya 24V jika pompa tinta putih atau pompa sirkulasi tinta putih berhenti bekerja.","breadcrumb":{"@id":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/km-602-24v-power-supply-inspection-and-replacement-guide\/#breadcrumb"},"inLanguage":"id","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/km-602-24v-power-supply-inspection-and-replacement-guide\/"]}]},{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/km-602-24v-power-supply-inspection-and-replacement-guide\/#primaryimage","url":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply.webp","contentUrl":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply.webp","width":1280,"height":960,"caption":"3.3-Measuring-The-DC-Output-Of-The-24V-Power-Supply"},{"@type":"BreadcrumbList","@id":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/km-602-24v-power-supply-inspection-and-replacement-guide\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.dtflinko.com\/"},{"@type":"ListItem","position":2,"name":"Support &#038; Technical Services","item":"https:\/\/www.dtflinko.com\/technical-services\/"},{"@type":"ListItem","position":3,"name":"Printer Technical Operation &amp; Repair","item":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/"},{"@type":"ListItem","position":4,"name":"Replace Power Supply- KM-602\uff5c24V Power Supply"}]},{"@type":"WebSite","@id":"https:\/\/www.dtflinko.com\/#website","url":"https:\/\/www.dtflinko.com\/","name":"Printer DTF LINKO","description":"Printer DTF","publisher":{"@id":"https:\/\/www.dtflinko.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.dtflinko.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"id"},{"@type":"Organization","@id":"https:\/\/www.dtflinko.com\/#organization","name":"LINKO","alternateName":"LINKO DTF PRINTERS MANUFACTURER","url":"https:\/\/www.dtflinko.com\/","logo":{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/www.dtflinko.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/09\/Linko-logo.png","contentUrl":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/09\/Linko-logo.png","width":1000,"height":1000,"caption":"LINKO"},"image":{"@id":"https:\/\/www.dtflinko.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/linkoprinter","https:\/\/x.com\/linkoprinter","https:\/\/www.youtube.com\/@LinkoPrinter","https:\/\/www.instagram.com\/linkoprinter\/","https:\/\/www.linkedin.com\/company\/dtflinko\/"]}]}},"_links":{"self":[{"href":"https:\/\/www.dtflinko.com\/id\/wp-json\/wp\/v2\/pages\/19162","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dtflinko.com\/id\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.dtflinko.com\/id\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.dtflinko.com\/id\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dtflinko.com\/id\/wp-json\/wp\/v2\/comments?post=19162"}],"version-history":[{"count":13,"href":"https:\/\/www.dtflinko.com\/id\/wp-json\/wp\/v2\/pages\/19162\/revisions"}],"predecessor-version":[{"id":19195,"href":"https:\/\/www.dtflinko.com\/id\/wp-json\/wp\/v2\/pages\/19162\/revisions\/19195"}],"up":[{"embeddable":true,"href":"https:\/\/www.dtflinko.com\/id\/wp-json\/wp\/v2\/pages\/15609"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dtflinko.com\/id\/wp-json\/wp\/v2\/media\/19144"}],"wp:attachment":[{"href":"https:\/\/www.dtflinko.com\/id\/wp-json\/wp\/v2\/media?parent=19162"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}