{"id":16425,"date":"2025-12-04T17:20:39","date_gmt":"2025-12-05T01:20:39","guid":{"rendered":"https:\/\/www.dtflinko.com\/?page_id=16425"},"modified":"2026-04-10T18:03:36","modified_gmt":"2026-04-11T02:03:36","slug":"guide-dinspection-et-de-remplacement-de-lalimentation-24-v-serie-k60","status":"publish","type":"page","link":"https:\/\/www.dtflinko.com\/fr\/technical-services\/printer-technical-operation-repair\/k60-series-24v-power-supply-inspection-replacement-guide\/","title":{"rendered":"S\u00e9rie K60 | Guide d&#039;inspection et de remplacement des alimentations 24 V"},"content":{"rendered":"<section class=\"section\" id=\"section_1324482723\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row\"  id=\"row-510577351\">\n\n\t<div id=\"col-684888541\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div id=\"text-2912957761\" class=\"text\">\n\t\t\n<h1>S\u00e9rie K60 | Guide d&#039;inspection et de remplacement des alimentations 24 V<\/h1>\n\t\t\n<style>\n#text-2912957761 {\n  text-align: left;\n}\n@media (min-width:850px) {\n  #text-2912957761 {\n    text-align: center;\n  }\n}\n<\/style>\n\t<\/div>\n\t\n<p>Mod\u00e8les compatibles\u00a0: Imprimantes DTF s\u00e9rie LINKO K60<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1419233200\">\n\n\t<div id=\"col-2050419203\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h2>1. <strong>Pr\u00e9sentation du module d&#039;alimentation<\/strong>:<\/h2>\n<p>Plusieurs modules d&#039;alimentation sont utilis\u00e9s \u00e0 l&#039;int\u00e9rieur de l&#039;imprimante pour fournir diff\u00e9rentes tensions aux diff\u00e9rents syst\u00e8mes.<\/p>\n<p>Alimentation 24V (Bloc d&#039;alimentation 24V)<br \/>Fournit une alimentation CC de 24 V pour :<\/p>\n<ul>\n<li>pompe de circulation d&#039;encre blanche<\/li>\n<li>Moteur \u00e0 encre blanche<\/li>\n<\/ul>\n<p>Autres modules d&#039;alimentation<br \/><strong>Alimentation 36V\u00a0:<\/strong> Pilote les moteurs X\/Y et les contr\u00f4leurs de moteurs<br \/><strong>Module d&#039;alimentation principal\u00a0:<\/strong> Fournit des tensions CC \u00e0 sorties multiples (42 V \/ 36 V \/ 24 V) \u00e0 la carte m\u00e8re, \u00e0 la carte chariot, au lit \u00e0 vide, aux ventilateurs de refroidissement, \u00e0 l&#039;\u00e9cran d&#039;affichage et \u00e0 la barre de levage automatique.<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Module-Overview.webp\" title=\"1-Pr\u00e9sentation du module d&#039;alimentation\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Module-Overview-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Pr\u00e9sentation du module d&#039;alimentation\" ids=\"16430\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Module-Overview-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Module-Overview-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Module-Overview-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Module-Overview-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Module-Overview-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Module-Overview-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Module-Overview.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>1-Pr\u00e9sentation du module d&#039;alimentation<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1047152078\">\n\n\t<div id=\"col-1924520385\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h2>2. Sch\u00e9ma de c\u00e2blage du bo\u00eetier d&#039;alimentation 24 V<\/h2>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/24V-Power-Supply-Wiring-Diagram.webp\" title=\"Sch\u00e9ma de c\u00e2blage d&#039;une alimentation 2-1-24V\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/24V-Power-Supply-Wiring-Diagram-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Sch\u00e9ma de c\u00e2blage d&#039;une alimentation 24 V\" ids=\"16431,17511\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/24V-Power-Supply-Wiring-Diagram-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/24V-Power-Supply-Wiring-Diagram-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/24V-Power-Supply-Wiring-Diagram-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/24V-Power-Supply-Wiring-Diagram-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/24V-Power-Supply-Wiring-Diagram-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/24V-Power-Supply-Wiring-Diagram-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/24V-Power-Supply-Wiring-Diagram.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>Sch\u00e9ma de c\u00e2blage d&#039;une alimentation 2-1-24V<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-24V-Power-Supply-Wiring-Diagram-Chinese.webp\" title=\"Sch\u00e9ma de c\u00e2blage d&#039;une alimentation 2-2-24V (en chinois)\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-24V-Power-Supply-Wiring-Diagram-Chinese-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Sch\u00e9ma de c\u00e2blage de l&#039;alimentation 24 V s\u00e9rie K60 (version chinoise)\" ids=\"16431,17511\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-24V-Power-Supply-Wiring-Diagram-Chinese-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-24V-Power-Supply-Wiring-Diagram-Chinese-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-24V-Power-Supply-Wiring-Diagram-Chinese-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-24V-Power-Supply-Wiring-Diagram-Chinese-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-24V-Power-Supply-Wiring-Diagram-Chinese-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-24V-Power-Supply-Wiring-Diagram-Chinese-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-24V-Power-Supply-Wiring-Diagram-Chinese.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>Sch\u00e9ma de c\u00e2blage d&#039;une alimentation 2-2-24V (en chinois)<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1597193853\">\n\n\t<div id=\"col-350786511\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<table width=\"913\">\n<tbody>\n<tr>\n<td width=\"369\"><span style=\"color: #000000;\">Cat\u00e9gorie<\/span><\/td>\n<td width=\"39\"><span style=\"color: #000000;\">Non.<\/span><\/td>\n<td width=\"103\"><span style=\"color: #000000;\">Interface<\/span><\/td>\n<td width=\"87\"><span style=\"color: #000000;\">IDENTIFIANT<\/span><\/td>\n<td width=\"315\"><span style=\"color: #000000;\">Description<\/span><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\"><span style=\"color: #000000;\">Entr\u00e9e CA (Alimentation externe \u2192 Alimentation 24 V)<\/span><\/td>\n<td><span style=\"color: #000000;\">\u2462<\/span><\/td>\n<td><span style=\"color: #000000;\">Sol (G)<\/span><\/td>\n<td><span style=\"color: #000000;\">\u2013<\/span><\/td>\n<td><span style=\"color: #000000;\">Mise \u00e0 la terre \/ Protection de s\u00e9curit\u00e9<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"color: #000000;\">\u2461<\/span><\/td>\n<td><span style=\"color: #000000;\">Neutre (N)<\/span><\/td>\n<td><span style=\"color: #000000;\">AC-N1<\/span><\/td>\n<td><span style=\"color: #000000;\">Chemin de retour du courant alternatif<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"color: #000000;\">1<\/span><\/td>\n<td><span style=\"color: #000000;\">En direct (L)<\/span><\/td>\n<td><span style=\"color: #000000;\">AC-L1<\/span><\/td>\n<td><span style=\"color: #000000;\">Entr\u00e9e CA<\/span><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\"><span style=\"color: #000000;\">Sortie CC (Alimentation 24 V \u2192 Moteur de pompe\/d&#039;agitation)<\/span><\/td>\n<td><span style=\"color: #000000;\">5<\/span><\/td>\n<td><span style=\"color: #000000;\">24 V positif<\/span><\/td>\n<td><span style=\"color: #000000;\">\u2013<\/span><\/td>\n<td><span style=\"color: #000000;\">Sortie vers la pompe de circulation \/ moteur d&#039;agitation (+)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"color: #000000;\">\u2463<\/span><\/td>\n<td><span style=\"color: #000000;\">24V N\u00e9gatif<\/span><\/td>\n<td><span style=\"color: #000000;\">\u2013<\/span><\/td>\n<td><span style=\"color: #000000;\">Sortie vers la pompe de circulation \/ moteur d&#039;agitation (\u2013)<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1946203434\">\n\n\t<div id=\"col-832063918\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h2>3. Proc\u00e9dure de d\u00e9pannage (IMPORTANT\u00a0: tester d\u2019abord le courant alternatif \u2192 puis le courant continu)<\/h2>\n<p><strong>\u26a0 Avis important<\/strong><br \/>S&#039;il n&#039;y a pas d&#039;entr\u00e9e CA sur les bornes \u2460\u2013\u2461, la sortie CC sur les bornes \u2463\u2013\u2464 affichera toujours 0V.<\/p>\n<p>C&#039;est normal et <strong>Cela ne signifie pas que l&#039;alimentation 24V est d\u00e9fectueuse.<\/strong>.<br \/>Toujours tester le <strong>Entr\u00e9e CA en premier<\/strong>, puis testez le <strong>Sortie CC<\/strong>.<\/p>\n<h3>3.1 Avertissement de s\u00e9curit\u00e9<\/h3>\n<ul>\n<li>L&#039;imprimante doit \u00eatre allum\u00e9e lors de la mesure de la tension.<\/li>\n<li>L&#039;alimentation doit \u00eatre coup\u00e9e lors du remplacement du bloc d&#039;alimentation.<\/li>\n<li>Portez des gants isolants et \u00e9vitez de toucher les circuits expos\u00e9s.<\/li>\n<\/ul>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On.webp\" title=\"3.1-Mise sous tension\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Mise sous tension\" ids=\"16433\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.1-Mise sous tension<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<h3>3.2 V\u00e9rifier l&#039;entr\u00e9e CA (\u2460\u2013\u2461)<\/h3>\n<p>Mode multim\u00e8tre\u00a0: <strong>600 V CA<\/strong><br \/>Points de test\u00a0:<\/p>\n<ul>\n<li>Sonde noire \u2192 \u2461 (AC-N1)<\/li>\n<li>Sonde rouge \u2192 \u2460 (AC-L1)<\/li>\n<\/ul>\n<p>Normal : 200\u2013240 V CA<br \/>\u2192 L&#039;entr\u00e9e CA est correcte. Passez aux tests de sortie CC.<\/p>\n<p>Valeur anormale\u00a0: tension de 0\u00a0V ou instable<br \/>\u2192 Il ne s&#039;agit pas d&#039;une panne d&#039;alimentation. Veuillez v\u00e9rifier\u00a0:<\/p>\n<ul>\n<li>Interrupteur principal sur OFF<\/li>\n<li>Arr\u00eat d&#039;urgence non rel\u00e2ch\u00e9<\/li>\n<li>La prise murale n&#039;est pas aliment\u00e9e.<\/li>\n<li>C\u00e2blage CA l\u00e2che<\/li>\n<li>Oxydation terminale<\/li>\n<li>C\u00e2ble endommag\u00e9<\/li>\n<\/ul>\n<h3>3.3 V\u00e9rifier la sortie CC (\u2463\u2013\u2464)<\/h3>\n<p>Mode multim\u00e8tre\u00a0: <strong>200 V CC<\/strong><br \/>Points de test\u00a0:<\/p>\n<ul>\n<li>Sonde rouge \u2192 \u2464 (24V +)<\/li>\n<li>Sonde noire \u2192 \u2463 (24V \u2013)<\/li>\n<\/ul>\n<div class=\"row\"  id=\"row-1714776558\">\n\n\t<div id=\"col-1130875284\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-DC-Output-Test-Points.webp\" title=\"3.3-Mesure -Sortie CC (Points de test \u2463\u2013\u2464)\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-DC-Output-Test-Points-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Points de test de mesure de la sortie CC\" ids=\"16434\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-DC-Output-Test-Points-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-DC-Output-Test-Points-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-DC-Output-Test-Points-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-DC-Output-Test-Points-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-DC-Output-Test-Points-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-DC-Output-Test-Points-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-DC-Output-Test-Points.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.3-Mesure -Sortie CC (Points de test \u2463\u2013\u2464)<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>3.3.1 R\u00e9sultats et interpr\u00e9tation des tests de sortie CC<\/p>\n<table>\n<thead>\n<tr>\n<th>R\u00e9sultat de sortie CC<\/th>\n<th>Statut<\/th>\n<th>Action<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>22\u201325V (\u00b110%) (le moteur de la pompe\/agitateur a une tension d&#039;entr\u00e9e normale)<\/td>\n<td>\u2705 La sortie d&#039;alimentation 24 V est normale<\/td>\n<td>Aucun remplacement n\u00e9cessaire<\/td>\n<\/tr>\n<tr>\n<td>22\u201325 V (\u00b1101 TP3T) mais le moteur de la pompe\/de l&#039;agitateur ne fonctionne pas<\/td>\n<td>\u2705 L&#039;alimentation \u00e9lectrique est normale \u2192 le probl\u00e8me ne vient pas de l\u00e0.<\/td>\n<td>V\u00e9rifier la tension d&#039;entr\u00e9e de la pompe\/du moteur<\/td>\n<\/tr>\n<tr>\n<td>0 V ou tr\u00e8s faible (entr\u00e9e CA confirm\u00e9e normale)<\/td>\n<td>\u274c D\u00e9faillance interne de l&#039;alimentation 24 V<\/td>\n<td>Remplacez l&#039;alimentation 24 V<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-DC-Output-22-25V.webp\" title=\"3.3.1-1-Sortie CC normale (22-25 V)\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-DC-Output-22-25V-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Sortie CC normale 22-25 V\" ids=\"16435\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-DC-Output-22-25V-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-DC-Output-22-25V-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-DC-Output-22-25V-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-DC-Output-22-25V-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-DC-Output-22-25V-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-DC-Output-22-25V-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-DC-Output-22-25V.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.3.1-1-Sortie CC normale (22-25 V)<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Abnormal-0.0V.webp\" title=\"3.3.1-2 Sortie CC anormale (0,0 V)\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Abnormal-0.0V-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Sortie CC anormale 0 0 V\" ids=\"16438\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Abnormal-0.0V-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Abnormal-0.0V-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Abnormal-0.0V-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Abnormal-0.0V-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Abnormal-0.0V-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Abnormal-0.0V-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Abnormal-0.0V.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.3.1-2 Sortie CC anormale (0,0 V)<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>3.3.2 Test suppl\u00e9mentaire de la tension d&#039;entr\u00e9e de la pompe\/du moteur d&#039;agitation<\/p>\n<table>\n<thead>\n<tr>\n<th>Tension d&#039;entr\u00e9e<\/th>\n<th>Jugement<\/th>\n<th>Action<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>0,0 V<\/td>\n<td>Absence de tension \u00e0 la pompe\/au moteur d&#039;agitation \u2192 c\u00e2blage endommag\u00e9 \/ oxydation des bornes<\/td>\n<td>V\u00e9rifier ou remplacer le c\u00e2blage<\/td>\n<\/tr>\n<tr>\n<td>22\u201325 V (\u00b1101 TP3T) mais la pompe\/le moteur ne fonctionne pas<\/td>\n<td>panne de la pompe ou du moteur d&#039;agitation<\/td>\n<td>Remplacer la pompe de circulation ou le moteur d&#039;agitation<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-Voltage-at-PumpStirring-Motor-Input.webp\" title=\"3.3.2 - Mesure de la tension \u00e0 l&#039;entr\u00e9e de la pompe et du moteur d&#039;agitation\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-Voltage-at-PumpStirring-Motor-Input-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Mesure de la tension \u00e0 l&#039;entr\u00e9e du moteur d&#039;agitation de la pompe\" ids=\"16437\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-Voltage-at-PumpStirring-Motor-Input-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-Voltage-at-PumpStirring-Motor-Input-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-Voltage-at-PumpStirring-Motor-Input-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-Voltage-at-PumpStirring-Motor-Input-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-Voltage-at-PumpStirring-Motor-Input-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-Voltage-at-PumpStirring-Motor-Input-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Measuring-Voltage-at-PumpStirring-Motor-Input.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.3.2 - Mesure de la tension \u00e0 l&#039;entr\u00e9e de la pompe et du moteur d&#039;agitation<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1582394984\">\n\n\t<div id=\"col-391643297\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h2>4. Remplacement de l&#039;alimentation 24 V<\/h2>\n<h3>4.1 \u00c9teignez l&#039;imprimante<\/h3>\n<ul>\n<li>Appuyez sur l&#039;arr\u00eat d&#039;urgence<\/li>\n<li>Coupez l&#039;alimentation principale.<\/li>\n<li>D\u00e9branchez le c\u00e2ble d&#039;alimentation<\/li>\n<\/ul>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch.webp\" title=\"4.1-1-Interrupteur d&#039;urgence\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Interrupteur d&#039;urgence\" ids=\"16444,16445\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.1-1-Interrupteur d&#039;urgence<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off.webp\" title=\"4.1-2-Mise hors tension\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Mise hors tension\" ids=\"16444,16445\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.1-2-Mise hors tension<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<h3>4.2 Retirez l&#039;ancien bloc d&#039;alimentation<\/h3>\n<p>4.2.1 D\u00e9brancher le c\u00e2blage<\/p>\n<ul>\n<li>Desserrez les bornes \u2460\u2013\u2464 dans l&#039;ordre<\/li>\n<li>Retirez chaque fil un par un.<\/li>\n<li>Prenez des photos nettes du c\u00e2blage pour la r\u00e9installation.<\/li>\n<\/ul>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Wiring-Record-Photo.webp\" title=\"4.2.1-Photo d&#039;enregistrement du c\u00e2blage\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Wiring-Record-Photo-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Photo d&#039;enregistrement du c\u00e2blage\" ids=\"16446\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Wiring-Record-Photo-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Wiring-Record-Photo-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Wiring-Record-Photo-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Wiring-Record-Photo-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Wiring-Record-Photo-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Wiring-Record-Photo-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Wiring-Record-Photo.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.2.1-Photo d&#039;enregistrement du c\u00e2blage<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>4.2.2 Retirer les vis de fixation<\/p>\n<ul>\n<li>Retirer la vis \u2460<\/li>\n<li>Desserrez la vis de fixation \u2461<\/li>\n<li>Retirez l&#039;ancien bloc d&#039;alimentation<\/li>\n<\/ul>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Mounting-Screws.webp\" title=\"4.2.2-1-Desserrage-des-vis-de-fixation\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Mounting-Screws-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Desserrer les vis de fixation\" ids=\"16447,16448\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Mounting-Screws-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Mounting-Screws-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Mounting-Screws-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Mounting-Screws-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Mounting-Screws-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Mounting-Screws-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Mounting-Screws.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.2.2-1-Desserrage-des-vis-de-fixation<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-24V-Power-Supply-Removed.webp\" title=\"4.2.2-2-Ancienne-Alimentation-24V-Retir\u00e9e\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-24V-Power-Supply-Removed-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Ancienne alimentation 24V retir\u00e9e\" ids=\"16447,16448\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-24V-Power-Supply-Removed-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-24V-Power-Supply-Removed-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-24V-Power-Supply-Removed-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-24V-Power-Supply-Removed-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-24V-Power-Supply-Removed-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-24V-Power-Supply-Removed-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-24V-Power-Supply-Removed.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.2.2-2-Ancienne-Alimentation-24V-Retir\u00e9e<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<h3>4.3 Installation du nouveau bloc d&#039;alimentation<\/h3>\n<p>4.3.1 Confirmer la correspondance du mod\u00e8le<br \/>Assurez-vous que le nouveau bloc d&#039;alimentation corresponde \u00e0 l&#039;original (tension, puissance, type de connecteur).<\/p>\n<p>4.3.2 Installation de montage<br \/>Alignez les trous de fixation \u2192 Maintenez la pi\u00e8ce dans la fente de positionnement \u2192 Serrez toutes les vis.<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Fixed-in-Position.webp\" title=\"4.3.2-Alimentation-Fixe-en-Position\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Fixed-in-Position-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Alimentation \u00e9lectrique fix\u00e9e en position\" ids=\"16449\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Fixed-in-Position-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Fixed-in-Position-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Fixed-in-Position-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Fixed-in-Position-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Fixed-in-Position-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Fixed-in-Position-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Fixed-in-Position.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.3.2-Alimentation-Fixe-en-Position<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>4.3.3 C\u00e2blage<\/p>\n<ul>\n<li>Suivez le sch\u00e9ma de c\u00e2blage (Figure 2)<\/li>\n<li>Ins\u00e9rez chaque fil compl\u00e8tement dans la borne.<\/li>\n<li>V\u00e9rifiez que le sens de la marche est correct et qu&#039;il n&#039;y a pas de connexions desserr\u00e9es.<\/li>\n<li>Serrez fermement les vis des bornes<\/li>\n<\/ul>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1753241427\">\n\n\t<div id=\"col-1752627841\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h2>5. V\u00e9rification de la mise sous tension<\/h2>\n<p>5.1 Rev\u00e9rifier le c\u00e2blage : s&#039;assurer que tous les c\u00e2bles sont bien connect\u00e9s et non invers\u00e9s.<\/p>\n<p>5.2 Branchez le c\u00e2ble d&#039;alimentation \u2192 Mettez l&#039;interrupteur principal sous tension (voir figure 3.1)<\/p>\n<p>5.3 Tournez le bouton d&#039;arr\u00eat d&#039;urgence dans le sens horaire pour r\u00e9tablir le courant (voir figure 5.3).<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1.webp\" title=\"5-Interrupteur d&#039;urgence\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Interrupteur d&#039;urgence s\u00e9rie K60\" ids=\"16450\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>5-Interrupteur d&#039;urgence<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>5.4 V\u00e9rification finale de l&#039;\u00e9tat<\/p>\n<p>Apr\u00e8s avoir effectu\u00e9 tous les c\u00e2blages et mis l&#039;appareil sous tension, veuillez suivre les \u00e9tapes suivantes pour v\u00e9rifier que le bo\u00eetier d&#039;alimentation fonctionne correctement\u00a0:<\/p>\n<ul>\n<li>V\u00e9rifiez les voyants lumineux du bo\u00eetier d&#039;alimentation.<\/li>\n<li>Utilisez un voltm\u00e8tre pour mesurer \u00e0 nouveau la tension \u00e0 la borne de sortie 24V.<\/li>\n<\/ul>\n<p>Fonctionnement normal<\/p>\n<ul>\n<li>Le voyant est allum\u00e9.<\/li>\n<li>Sortie CC : 22\u201325 V<\/li>\n<\/ul>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Normal-Situation.webp\" title=\"5.4-1-Situation-Normale\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Normal-Situation-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Situation normale\" ids=\"16451\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Normal-Situation-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Normal-Situation-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Normal-Situation-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Normal-Situation-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Normal-Situation-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Normal-Situation-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Normal-Situation.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>5.4-1-Situation-Normale<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>Fonctionnement anormal<\/p>\n<ul>\n<li>Voyant \u00e9teint ou clignotant<\/li>\n<li>Tension continue 0,0 V<\/li>\n<\/ul>\n<p>\u2192 Rev\u00e9rifiez le c\u00e2blage ou remplacez l&#039;alimentation \u00e9lectrique.<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Abnormal-Situation.webp\" title=\"5.4-2-Situation-anormale\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Abnormal-Situation-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Situation anormale\" ids=\"16452\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Abnormal-Situation-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Abnormal-Situation-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Abnormal-Situation-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Abnormal-Situation-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Abnormal-Situation-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Abnormal-Situation-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Abnormal-Situation.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>5.4-2-Situation-anormale<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1046664925\">\n\n\t<div id=\"col-373370601\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<p><span style=\"color: #333399;\"><strong>Assistance technique LINKO<\/strong><\/span><\/p>\n<p>Courriel : <a href=\"mailto:support@dtflinko.com\">support@dtflinko.com<\/a><\/p>\n<p>Site web : <a href=\"https:\/\/www.dtflinko.com\/fr\/\">www.dtflinko.com<\/a><\/p>\n<p>\u00a9 2025 \u00c9quipe technique LINKO. Tous droits r\u00e9serv\u00e9s.<\/p>\n<p>Toute reproduction ou modification sans autorisation est interdite.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1324482723 {\n  padding-top: 60px;\n  padding-bottom: 60px;\n}\n<\/style>\n\t<\/section>","protected":false},"excerpt":{"rendered":"","protected":false},"author":3,"featured_media":0,"parent":15609,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-blank.php","meta":{"footnotes":""},"class_list":["post-16425","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>K60 Series\uff5c24V Power Supply Inspection &amp; Replacement Guide - LINKO DTF Printer<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.dtflinko.com\/fr\/services-techniques\/reparation-technique-de-limprimante\/guide-dinspection-et-de-remplacement-de-lalimentation-24-v-serie-k60\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"K60 Series\uff5c24V Power Supply Inspection &amp; Replacement Guide - LINKO DTF Printer\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.dtflinko.com\/fr\/services-techniques\/reparation-technique-de-limprimante\/guide-dinspection-et-de-remplacement-de-lalimentation-24-v-serie-k60\/\" \/>\n<meta property=\"og:site_name\" content=\"LINKO DTF Printer\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/linkoprinter\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-11T02:03:36+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/03\/2025-linko-dtf-printer-and-uv-dtf-printer.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1080\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@linkoprinter\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/it\\\/servizi-tecnici\\\/riparazione-funzionamento-tecnico-stampante\\\/guida-alla-sostituzione-e-allispezione-dellalimentatore-da-24-v-della-serie-k60\\\/\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/it\\\/servizi-tecnici\\\/riparazione-funzionamento-tecnico-stampante\\\/guida-alla-sostituzione-e-allispezione-dellalimentatore-da-24-v-della-serie-k60\\\/\",\"name\":\"K60 Series\uff5c24V Power Supply Inspection & Replacement Guide - LINKO DTF Printer\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/#website\"},\"datePublished\":\"2025-12-05T01:20:39+00:00\",\"dateModified\":\"2026-04-11T02:03:36+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/it\\\/servizi-tecnici\\\/riparazione-funzionamento-tecnico-stampante\\\/guida-alla-sostituzione-e-allispezione-dellalimentatore-da-24-v-della-serie-k60\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.dtflinko.com\\\/it\\\/servizi-tecnici\\\/riparazione-funzionamento-tecnico-stampante\\\/guida-alla-sostituzione-e-allispezione-dellalimentatore-da-24-v-della-serie-k60\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/it\\\/servizi-tecnici\\\/riparazione-funzionamento-tecnico-stampante\\\/guida-alla-sostituzione-e-allispezione-dellalimentatore-da-24-v-della-serie-k60\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Support &#038; Technical Services\",\"item\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/technicke-sluzby\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Printer Technical Operation &amp; Repair\",\"item\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/technicke-sluzby\\\/oprava-technickeho-provozu-tiskarny\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"K60 Series\uff5c24V Power Supply Inspection &#038; Replacement Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/#website\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/\",\"name\":\"LINKO DTF Printer\",\"description\":\"DTF Printer\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/#organization\",\"name\":\"LINKO\",\"alternateName\":\"LINKO DTF PRINTERS MANUFACTURER\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Linko-logo.png\",\"contentUrl\":\"https:\\\/\\\/www.dtflinko.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Linko-logo.png\",\"width\":1000,\"height\":1000,\"caption\":\"LINKO\"},\"image\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/linkoprinter\",\"https:\\\/\\\/x.com\\\/linkoprinter\",\"https:\\\/\\\/www.youtube.com\\\/@LinkoPrinter\",\"https:\\\/\\\/www.instagram.com\\\/linkoprinter\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/dtflinko\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"S\u00e9rie K60 | Guide d&#039;inspection et de remplacement de l&#039;alimentation 24 V - Imprimante DTF LINKO","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.dtflinko.com\/fr\/services-techniques\/reparation-technique-de-limprimante\/guide-dinspection-et-de-remplacement-de-lalimentation-24-v-serie-k60\/","og_locale":"fr_FR","og_type":"article","og_title":"K60 Series\uff5c24V Power Supply Inspection & Replacement Guide - LINKO DTF Printer","og_url":"https:\/\/www.dtflinko.com\/fr\/services-techniques\/reparation-technique-de-limprimante\/guide-dinspection-et-de-remplacement-de-lalimentation-24-v-serie-k60\/","og_site_name":"LINKO DTF Printer","article_publisher":"https:\/\/www.facebook.com\/linkoprinter","article_modified_time":"2026-04-11T02:03:36+00:00","og_image":[{"width":1080,"height":1080,"url":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/03\/2025-linko-dtf-printer-and-uv-dtf-printer.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_site":"@linkoprinter","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.dtflinko.com\/it\/servizi-tecnici\/riparazione-funzionamento-tecnico-stampante\/guida-alla-sostituzione-e-allispezione-dellalimentatore-da-24-v-della-serie-k60\/","url":"https:\/\/www.dtflinko.com\/it\/servizi-tecnici\/riparazione-funzionamento-tecnico-stampante\/guida-alla-sostituzione-e-allispezione-dellalimentatore-da-24-v-della-serie-k60\/","name":"S\u00e9rie K60 | Guide d&#039;inspection et de remplacement de l&#039;alimentation 24 V - Imprimante DTF LINKO","isPartOf":{"@id":"https:\/\/www.dtflinko.com\/cs\/#website"},"datePublished":"2025-12-05T01:20:39+00:00","dateModified":"2026-04-11T02:03:36+00:00","breadcrumb":{"@id":"https:\/\/www.dtflinko.com\/it\/servizi-tecnici\/riparazione-funzionamento-tecnico-stampante\/guida-alla-sostituzione-e-allispezione-dellalimentatore-da-24-v-della-serie-k60\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.dtflinko.com\/it\/servizi-tecnici\/riparazione-funzionamento-tecnico-stampante\/guida-alla-sostituzione-e-allispezione-dellalimentatore-da-24-v-della-serie-k60\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.dtflinko.com\/it\/servizi-tecnici\/riparazione-funzionamento-tecnico-stampante\/guida-alla-sostituzione-e-allispezione-dellalimentatore-da-24-v-della-serie-k60\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.dtflinko.com\/cs\/"},{"@type":"ListItem","position":2,"name":"Support &#038; Technical Services","item":"https:\/\/www.dtflinko.com\/cs\/technicke-sluzby\/"},{"@type":"ListItem","position":3,"name":"Printer Technical Operation &amp; Repair","item":"https:\/\/www.dtflinko.com\/cs\/technicke-sluzby\/oprava-technickeho-provozu-tiskarny\/"},{"@type":"ListItem","position":4,"name":"K60 Series\uff5c24V Power Supply Inspection &#038; Replacement Guide"}]},{"@type":"WebSite","@id":"https:\/\/www.dtflinko.com\/cs\/#website","url":"https:\/\/www.dtflinko.com\/cs\/","name":"LINKO DTF Imprimante","description":"Imprimante DTF","publisher":{"@id":"https:\/\/www.dtflinko.com\/cs\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.dtflinko.com\/cs\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.dtflinko.com\/cs\/#organization","name":"LINKO","alternateName":"LINKO DTF PRINTERS MANUFACTURER","url":"https:\/\/www.dtflinko.com\/cs\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.dtflinko.com\/cs\/#\/schema\/logo\/image\/","url":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/09\/Linko-logo.png","contentUrl":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/09\/Linko-logo.png","width":1000,"height":1000,"caption":"LINKO"},"image":{"@id":"https:\/\/www.dtflinko.com\/cs\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/linkoprinter","https:\/\/x.com\/linkoprinter","https:\/\/www.youtube.com\/@LinkoPrinter","https:\/\/www.instagram.com\/linkoprinter\/","https:\/\/www.linkedin.com\/company\/dtflinko\/"]}]}},"_links":{"self":[{"href":"https:\/\/www.dtflinko.com\/fr\/wp-json\/wp\/v2\/pages\/16425","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dtflinko.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.dtflinko.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.dtflinko.com\/fr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dtflinko.com\/fr\/wp-json\/wp\/v2\/comments?post=16425"}],"version-history":[{"count":10,"href":"https:\/\/www.dtflinko.com\/fr\/wp-json\/wp\/v2\/pages\/16425\/revisions"}],"predecessor-version":[{"id":17865,"href":"https:\/\/www.dtflinko.com\/fr\/wp-json\/wp\/v2\/pages\/16425\/revisions\/17865"}],"up":[{"embeddable":true,"href":"https:\/\/www.dtflinko.com\/fr\/wp-json\/wp\/v2\/pages\/15609"}],"wp:attachment":[{"href":"https:\/\/www.dtflinko.com\/fr\/wp-json\/wp\/v2\/media?parent=16425"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}