{"id":16341,"date":"2025-11-28T00:49:51","date_gmt":"2025-11-28T08:49:51","guid":{"rendered":"https:\/\/www.dtflinko.com\/?page_id=16341"},"modified":"2026-05-22T20:09:59","modified_gmt":"2026-05-23T04:09:59","slug":"remplacement-du-capteur-de-la-station-dencre","status":"publish","type":"page","link":"https:\/\/www.dtflinko.com\/fr\/technical-services\/printer-technical-operation-repair\/ink-station-sensor-check-replacement\/","title":{"rendered":"V\u00e9rification et remplacement du capteur de la station d&#039;encre"},"content":{"rendered":"<section class=\"section\" id=\"section_1606505001\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row\"  id=\"row-1428816217\">\n\n\t<div id=\"col-319358028\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h1>Guide d&#039;inspection et de remplacement du capteur de la station d&#039;encre<\/h1>\n<p><strong>Mod\u00e8le applicable :<\/strong> Imprimante DTF LINKO K605B<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-2062433082\">\n\n\t<div id=\"col-367203746\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h2>\u00c9tape 1. Pr\u00e9paration<\/h2>\n<p>1.1 <strong>Actionnez le bouton d&#039;arr\u00eat d&#039;urgence\u00a0:<\/strong> Appuyez dessus pour arr\u00eater tout mouvement. (Voir figure 1.1)<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B.webp\" title=\"1.1-Interrupteur d&#039;urgence\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Interrupteur d&#039;urgence\" ids=\"16344\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>1.1-Interrupteur d&#039;urgence<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>1.2 Avertissement de s\u00e9curit\u00e9 : Coupez l&#039;alimentation et d\u00e9branchez la machine avant d&#039;effectuer tout travail.<\/p>\n<p>Cela \u00e9vite d&#039;endommager le capteur de la station d&#039;encre et pr\u00e9vient les chocs \u00e9lectriques.<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-Off-Carriage-Board-Replacement-and-Wiring.webp\" title=\"1.2-1-Mise hors tension\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-Off-Carriage-Board-Replacement-and-Wiring-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Remplacement et c\u00e2blage de la carte de chariot hors tension\" ids=\"15707,15646\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-Off-Carriage-Board-Replacement-and-Wiring-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-Off-Carriage-Board-Replacement-and-Wiring-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-Off-Carriage-Board-Replacement-and-Wiring-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-Off-Carriage-Board-Replacement-and-Wiring-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-Off-Carriage-Board-Replacement-and-Wiring-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-Off-Carriage-Board-Replacement-and-Wiring-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-Off-Carriage-Board-Replacement-and-Wiring.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>1.2-1-Mise hors tension<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-On-Replace-Mainboard-and-Wiring.webp\" title=\"1.2-2-Mise sous tension\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-On-Replace-Mainboard-and-Wiring-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Mise sous tension, remplacement de la carte m\u00e8re et du c\u00e2blage\" ids=\"15707,15646\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-On-Replace-Mainboard-and-Wiring-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-On-Replace-Mainboard-and-Wiring-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-On-Replace-Mainboard-and-Wiring-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-On-Replace-Mainboard-and-Wiring-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-On-Replace-Mainboard-and-Wiring-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-On-Replace-Mainboard-and-Wiring-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-On-Replace-Mainboard-and-Wiring.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>1.2-2-Mise sous tension<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>1.3 <strong>Conseil : Prenez une photo nette<\/strong> du capteur de la station d&#039;encre et de son c\u00e2blage.<br \/>Cette photo vous aidera \u00e0 r\u00e9installer correctement le capteur.<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Photo.webp\" title=\"1.3-Capteur-Photo\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Photo-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Photo du capteur de casquette\" ids=\"16345\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Photo-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Photo-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Photo-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Photo-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Photo-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Photo-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Photo.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>1.3-Capteur-Photo<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-826303041\">\n\n\t<div id=\"col-1334728545\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h2>\u00c9tape 2. Retirez l&#039;ancien capteur de la station d&#039;encre<\/h2>\n<p>D\u00e9vissez la vis qui fixe le capteur de la station d&#039;encre. (Voir figure 2.1)<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Screw.webp\" title=\"2.1-Capteur-Vis\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Screw-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Vis du capteur de capuchon\" ids=\"16346\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Screw-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Screw-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Screw-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Screw-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Screw-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Screw-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Screw.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>2.1-Capteur-Vis<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>2.2 D\u00e9branchez le c\u00e2ble du capteur de la station d&#039;encre. (Voir figure 2.2-1)<\/p>\n<p>Retirez l&#039;ancien capteur de la station d&#039;encre. (Voir figure 2.2-2)<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-Cable.webp\" title=\"2.2-1-Station d&#039;encre-Capteur-C\u00e2ble \">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-Cable-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"c\u00e2ble du capteur de capuchon\" ids=\"16347,16348\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-Cable-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-Cable-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-Cable-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-Cable-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-Cable-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-Cable-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-Cable.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>2.2-1-Station d&#039;encre-Capteur-C\u00e2ble <\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor.webp\" title=\"2.2-2-Capteur-Station-Encre \">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"le capteur de capuchon\" ids=\"16347,16348\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>2.2-2-Capteur-Station-Encre <\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-146692612\">\n\n\t<div id=\"col-1897165094\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h2>\u00c9tape 3. Installez le nouveau capteur de station d&#039;encre<\/h2>\n<p>3.1 Assurez-vous que le nouveau mod\u00e8le de capteur de station d&#039;encre correspond \u00e0 l&#039;ancien.<br \/>3.2 Branchez le c\u00e2ble au nouveau capteur de la station d&#039;encre. (Voir figure 3.2)<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Plag-the-Cap-Sensor-Cable-.webp\" title=\"3.2-Plag-the-Cap-Sensor-Cable \">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Plag-the-Cap-Sensor-Cable--500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Branchez le c\u00e2ble du capteur de capuchon\" ids=\"16349\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Plag-the-Cap-Sensor-Cable--500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Plag-the-Cap-Sensor-Cable--1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Plag-the-Cap-Sensor-Cable--400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Plag-the-Cap-Sensor-Cable--768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Plag-the-Cap-Sensor-Cable--16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Plag-the-Cap-Sensor-Cable--600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Plag-the-Cap-Sensor-Cable-.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.2-Plag-the-Cap-Sensor-Cable <\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>3.3 Alignez les trous de fixation. Placez le nouveau capteur de station d&#039;encre en position et serrez la vis. (Voir figure 2.1)<\/p>\n<p><strong>Conseil:<\/strong> Apr\u00e8s avoir connect\u00e9 le c\u00e2ble, prenez une photo nette du c\u00e2blage et envoyez-la \u00e0 l&#039;\u00e9quipe d&#039;assistance technique de LINKO pour confirmation avant la mise sous tension.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1998604927\">\n\n\t<div id=\"col-755758684\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h2>\u00c9tape 4. V\u00e9rification de la mise sous tension<\/h2>\n<p>4.1 Assurez-vous que le c\u00e2ble est enti\u00e8rement ins\u00e9r\u00e9 et non invers\u00e9.<br \/>4.2 Branchez le cordon d&#039;alimentation et mettez l&#039;appareil sous tension \u00e0 l&#039;aide de l&#039;interrupteur principal. (Voir figure 1.1-2)<br \/>4.3 Assurez-vous que l\u2019interrupteur d\u2019arr\u00eat d\u2019urgence est en position \u00ab rel\u00e2ch\u00e9e \u00bb. (Voir figure 4.3)<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-1.webp\" title=\"4.3-Interrupteur d&#039;urgence\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-1-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Interrupteur d&#039;urgence\" ids=\"16350\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-1-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-1-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-1-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-1-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-1-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-1-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-1.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.3-Interrupteur d&#039;urgence<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>4.4 V\u00e9rifier l&#039;indicateur du capteur de position initiale de la station d&#039;encre de la carte m\u00e8re<\/p>\n<p>Lors de la mise \u00e0 l&#039;origine du chariot, observez l&#039;indicateur du capteur de la station d&#039;encre sur la carte m\u00e8re\u00a0:<\/p>\n<p>\u2705 Normal :<br \/>\u00c0 la maison, cela signifie que la carte m\u00e8re d\u00e9tecte correctement la position de la station d&#039;encre \u2192 Voyant allum\u00e9. (Voir figure 4.4-1)<br \/>En cas de non-d\u00e9tection du signal du capteur de la station d&#039;encre, le voyant s&#039;\u00e9teint. (Voir figure 4.4-2)<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Normal.webp\" title=\"4.4-1-Capteur-domestique-Normal\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Normal-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Capteur de domicile normal\" ids=\"16352,16353\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Normal-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Normal-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Normal-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Normal-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Normal-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Normal-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Normal.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.4-1-Capteur-domestique-Normal<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Abnormal.webp\" title=\"4.4-2-Domicile-Capteur-Anormal\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Abnormal-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Capteur domestique anormal\" ids=\"16352,16353\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Abnormal-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Abnormal-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Abnormal-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Abnormal-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Abnormal-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Abnormal-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Abnormal.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.4-2-Domicile-Capteur-Anormal<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>\u274c Anormal :<br \/>La lumi\u00e8re reste soit toujours allum\u00e9e, soit toujours \u00e9teinte, ind\u00e9pendamment du mouvement du chariot. (Voir figure 4.4-2)<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-171545643\">\n\n\t<div id=\"col-453285520\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<p><strong>Annexe \u2013 Quand le capteur de la station d&#039;encre doit \u00eatre remplac\u00e9<\/strong><\/p>\n<p>Le capteur de la station d&#039;encre doit \u00eatre remplac\u00e9 dans les conditions suivantes\u00a0:<\/p>\n<ul>\n<li>Le signal de retour au point de d\u00e9part n&#039;est pas d\u00e9tect\u00e9 pendant le retour du chariot \u00e0 son point de d\u00e9part.<\/li>\n<li>Le voyant du capteur de position initiale de la station d&#039;encre ne s&#039;allume pas lorsque la t\u00eate d&#039;impression atteint la station d&#039;encre.<\/li>\n<li>Le nettoyage ou le pompage ne d\u00e9marre pas.<\/li>\n<li>La t\u00eate d&#039;impression ne peut pas \u00eatre correctement bouch\u00e9e.<\/li>\n<li>Le signal du capteur est instable ou intermittent.<\/li>\n<li>Le capteur pr\u00e9sente des signes de contamination, de corrosion ou de dommages physiques.<\/li>\n<li>Le capteur ne r\u00e9pond pas apr\u00e8s reconnexion ou v\u00e9rifications r\u00e9p\u00e9t\u00e9es.<\/li>\n<\/ul>\n<p>Le capteur de la station d&#039;encre est un <strong>composant \u00e9lectronique consommable<\/strong>et ses performances peuvent se d\u00e9grader avec le temps en raison de l&#039;humidit\u00e9, des brouillards d&#039;encre, des vibrations, de l&#039;oxydation ou du vieillissement.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1349453561\">\n\n\t<div id=\"col-884163518\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<p>Pour obtenir de l&#039;aide, contactez l&#039;\u00e9quipe d&#039;assistance technique de LINKO.<\/p>\n<div class=\"is-divider divider clearfix\" style=\"max-width:2000px;height:2px;\"><\/div>\n<p>\u00a9 2025 \u00c9quipe technique LINKO. Tous droits r\u00e9serv\u00e9s.<br \/>La reproduction ou la modification de ce document est interdite.<br \/>Soutien: <a href=\"mailto:support@dtflinko.com\">support@dtflinko.com<\/a> | <a href=\"https:\/\/www.dtflinko.com\/fr\/\">www.dtflinko.com<\/a><\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1606505001 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n}\n@media (min-width:550px) {\n  #section_1606505001 {\n    padding-top: 60px;\n    padding-bottom: 60px;\n  }\n}\n<\/style>\n\t<\/section>","protected":false},"excerpt":{"rendered":"","protected":false},"author":3,"featured_media":0,"parent":15609,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-blank.php","meta":{"footnotes":""},"class_list":["post-16341","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Ink Station Sensor Check &amp; Replacement - LINKO DTF Printer<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.dtflinko.com\/fr\/services-techniques\/reparation-technique-de-limprimante\/remplacement-du-capteur-de-la-station-dencre\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Ink Station Sensor Check &amp; Replacement - LINKO DTF Printer\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.dtflinko.com\/fr\/services-techniques\/reparation-technique-de-limprimante\/remplacement-du-capteur-de-la-station-dencre\/\" \/>\n<meta property=\"og:site_name\" content=\"LINKO DTF Printer\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/linkoprinter\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-23T04:09:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/03\/2025-linko-dtf-printer-and-uv-dtf-printer.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1080\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@linkoprinter\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/ink-station-sensor-check-replacement\\\/\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/ink-station-sensor-check-replacement\\\/\",\"name\":\"Ink Station Sensor Check & Replacement - LINKO DTF Printer\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/#website\"},\"datePublished\":\"2025-11-28T08:49:51+00:00\",\"dateModified\":\"2026-05-23T04:09:59+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/ink-station-sensor-check-replacement\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/ink-station-sensor-check-replacement\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/ink-station-sensor-check-replacement\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.dtflinko.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Support &#038; Technical Services\",\"item\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Printer Technical Operation &amp; Repair\",\"item\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Ink Station Sensor Check &#038; Replacement\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/#website\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/\",\"name\":\"LINKO DTF Printer\",\"description\":\"DTF Printer\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.dtflinko.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/#organization\",\"name\":\"LINKO\",\"alternateName\":\"LINKO DTF PRINTERS MANUFACTURER\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Linko-logo.png\",\"contentUrl\":\"https:\\\/\\\/www.dtflinko.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Linko-logo.png\",\"width\":1000,\"height\":1000,\"caption\":\"LINKO\"},\"image\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/linkoprinter\",\"https:\\\/\\\/x.com\\\/linkoprinter\",\"https:\\\/\\\/www.youtube.com\\\/@LinkoPrinter\",\"https:\\\/\\\/www.instagram.com\\\/linkoprinter\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/dtflinko\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"V\u00e9rification et remplacement du capteur de la station d&#039;encre - Imprimante LINKO DTF","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.dtflinko.com\/fr\/services-techniques\/reparation-technique-de-limprimante\/remplacement-du-capteur-de-la-station-dencre\/","og_locale":"fr_FR","og_type":"article","og_title":"Ink Station Sensor Check & Replacement - LINKO DTF Printer","og_url":"https:\/\/www.dtflinko.com\/fr\/services-techniques\/reparation-technique-de-limprimante\/remplacement-du-capteur-de-la-station-dencre\/","og_site_name":"LINKO DTF Printer","article_publisher":"https:\/\/www.facebook.com\/linkoprinter","article_modified_time":"2026-05-23T04:09:59+00:00","og_image":[{"width":1080,"height":1080,"url":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/03\/2025-linko-dtf-printer-and-uv-dtf-printer.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_site":"@linkoprinter","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/ink-station-sensor-check-replacement\/","url":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/ink-station-sensor-check-replacement\/","name":"V\u00e9rification et remplacement du capteur de la station d&#039;encre - Imprimante LINKO DTF","isPartOf":{"@id":"https:\/\/www.dtflinko.com\/#website"},"datePublished":"2025-11-28T08:49:51+00:00","dateModified":"2026-05-23T04:09:59+00:00","breadcrumb":{"@id":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/ink-station-sensor-check-replacement\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/ink-station-sensor-check-replacement\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/ink-station-sensor-check-replacement\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.dtflinko.com\/"},{"@type":"ListItem","position":2,"name":"Support &#038; Technical Services","item":"https:\/\/www.dtflinko.com\/technical-services\/"},{"@type":"ListItem","position":3,"name":"Printer Technical Operation &amp; Repair","item":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/"},{"@type":"ListItem","position":4,"name":"Ink Station Sensor Check &#038; Replacement"}]},{"@type":"WebSite","@id":"https:\/\/www.dtflinko.com\/#website","url":"https:\/\/www.dtflinko.com\/","name":"LINKO DTF Imprimante","description":"Imprimante DTF","publisher":{"@id":"https:\/\/www.dtflinko.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.dtflinko.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.dtflinko.com\/#organization","name":"LINKO","alternateName":"LINKO DTF PRINTERS MANUFACTURER","url":"https:\/\/www.dtflinko.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.dtflinko.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/09\/Linko-logo.png","contentUrl":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/09\/Linko-logo.png","width":1000,"height":1000,"caption":"LINKO"},"image":{"@id":"https:\/\/www.dtflinko.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/linkoprinter","https:\/\/x.com\/linkoprinter","https:\/\/www.youtube.com\/@LinkoPrinter","https:\/\/www.instagram.com\/linkoprinter\/","https:\/\/www.linkedin.com\/company\/dtflinko\/"]}]}},"_links":{"self":[{"href":"https:\/\/www.dtflinko.com\/fr\/wp-json\/wp\/v2\/pages\/16341","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dtflinko.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.dtflinko.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.dtflinko.com\/fr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dtflinko.com\/fr\/wp-json\/wp\/v2\/comments?post=16341"}],"version-history":[{"count":5,"href":"https:\/\/www.dtflinko.com\/fr\/wp-json\/wp\/v2\/pages\/16341\/revisions"}],"predecessor-version":[{"id":18033,"href":"https:\/\/www.dtflinko.com\/fr\/wp-json\/wp\/v2\/pages\/16341\/revisions\/18033"}],"up":[{"embeddable":true,"href":"https:\/\/www.dtflinko.com\/fr\/wp-json\/wp\/v2\/pages\/15609"}],"wp:attachment":[{"href":"https:\/\/www.dtflinko.com\/fr\/wp-json\/wp\/v2\/media?parent=16341"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}