{"id":19162,"date":"2026-08-17T13:22:02","date_gmt":"2026-08-17T05:22:02","guid":{"rendered":"https:\/\/www.dtflinko.com\/?page_id=19162"},"modified":"2026-08-17T14:19:20","modified_gmt":"2026-08-17T06:19:20","slug":"leitfaden-zur-inspektion-und-zum-austausch-des-24-v-netzteils-km-602","status":"publish","type":"page","link":"https:\/\/www.dtflinko.com\/de\/technical-services\/printer-technical-operation-repair\/km-602-24v-power-supply-inspection-and-replacement-guide\/","title":{"rendered":"Netzteil austauschen \u2013 KM-602\uff5c24V Netzteil"},"content":{"rendered":"<section class=\"section\" id=\"section_593628082\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row\"  id=\"row-54746835\">\n\n\t<div id=\"col-285708537\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div id=\"text-736939469\" class=\"text\">\n\t\t\n<h1 style=\"text-align: center;\">KM-602\uff5c24V-Netzteil \u2013 Leitfaden zur Inspektion und zum Austausch<\/h1>\n\t\t\n<style>\n#text-736939469 {\n  text-align: center;\n}\n<\/style>\n\t<\/div>\n\t\n\t<div id=\"text-1929568324\" class=\"text\">\n\t\t\n<p style=\"text-align: left;\"><strong>Anwendbares Modell:<\/strong> LINKO KM-602 DTF-Drucker<\/p>\n<p style=\"text-align: left;\"><strong>Wann Sie diesen Leitfaden verwenden sollten:<\/strong> Die Umw\u00e4lzpumpe f\u00fcr die wei\u00dfe Tinte bzw. der R\u00fchrmotor f\u00fcr die wei\u00dfe Tinte funktioniert nicht.<\/p>\n<p style=\"text-align: left;\"><strong>Erforderliche Werkzeuge:<\/strong> Multimeter, Kreuzschlitzschraubendreher, isolierende Handschuhe.<\/p>\n\t\t\n<style>\n#text-1929568324 {\n  text-align: center;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-197119502\">\n\n\t<div id=\"col-467162300\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<span class=\"scroll-to\" data-label=\"Scroll to: #1.-printer-power-module-overview\" data-bullet=\"true\" data-link=\"#1.-printer-power-module-overview\" data-title=\"1. Printer Power Module Overview\"><a name=\"1.-printer-power-module-overview\"><\/a><\/span>\n<h2>1. \u00dcbersicht des Drucker-Netzteilmoduls<\/h2>\n<p>Der Drucker verwendet mehrere Netzteile. Jedes Netzteil versorgt ein anderes System. Das 24-V-Netzteil ist die unabh\u00e4ngige Stromversorgung f\u00fcr das Wei\u00dftintensystem. Es liefert eine Gleichspannung von 24 V.<\/p>\n<table>\n<thead>\n<tr>\n<th>Leistungsmodul<\/th>\n<th>Komponentenbetrieben<\/th>\n<th>Verwandtes Dokument<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Mehrfachausgangs-Leistungsmodul<\/td>\n<td>Hauptplatine, Schlittenplatine, X-Achsen-Motor, Y-Achsen-Motor, Bildschirmtreiberplatine, L\u00fcfter<\/td>\n<td><a href=\"https:\/\/www.dtflinko.com\/de\/technische-dienstleistungen\/reparatur-des-technischen-betriebs-des-druckers\/leitfaden-zur-inspektion-und-zum-austausch-des-mehrfachausgangsleistungsmoduls-km-602\/\">KM-602 | Leitfaden zur Inspektion und zum Austausch von Mehrfachausgangs-Leistungsmodulen<\/a><\/td>\n<\/tr>\n<tr>\n<td>24V Netzteil<\/td>\n<td>Umw\u00e4lzpumpe f\u00fcr wei\u00dfe Tinte, R\u00fchrmotor f\u00fcr wei\u00dfe Tinte<\/td>\n<td>Dieser Leitfaden<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/1-Location-Of-The-Power-Modules.webp\" title=\"1. Standort der Leistungsmodule\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/1-Location-Of-The-Power-Modules-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"1. Standort der Leistungsmodule\" ids=\"19159\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/1-Location-Of-The-Power-Modules-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/1-Location-Of-The-Power-Modules-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/1-Location-Of-The-Power-Modules-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/1-Location-Of-The-Power-Modules-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/1-Location-Of-The-Power-Modules-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/1-Location-Of-The-Power-Modules-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/1-Location-Of-The-Power-Modules.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>1. Standort der Leistungsmodule<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-805023269\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>1.1 Andere unabh\u00e4ngige Stromversorgungsmodule (werden in diesem Leitfaden nicht behandelt)<\/h3>\n<p>Diese Anleitung gilt nur f\u00fcr das 24-V-Netzteil. Das Mehrfachausgangs-Netzteilmodul versorgt die Hauptplatine, die Schlittenplatine, den X-Achsen-Motor, den Y-Achsen-Motor, die Bildschirmtreiberplatine und den L\u00fcfter. Weitere Informationen zum Mehrfachausgangs-Netzteilmodul finden Sie in der entsprechenden Anleitung. <a href=\"https:\/\/www.dtflinko.com\/de\/technische-dienstleistungen\/reparatur-des-technischen-betriebs-des-druckers\/leitfaden-zur-inspektion-und-zum-austausch-des-mehrfachausgangsleistungsmoduls-km-602\/\">KM-602\uff5cLeitfaden zur Inspektion und zum Austausch von Mehrfachausgangs-Leistungsmodulen.<\/a><\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1507812751\">\n\n\t<div id=\"col-1303432914\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<span class=\"scroll-to\" data-label=\"Scroll to: #2.-24v-power-supply-wiring-diagram\" data-bullet=\"true\" data-link=\"#2.-24v-power-supply-wiring-diagram\" data-title=\"2. 24V Power Supply Wiring Diagram\"><a name=\"2.-24v-power-supply-wiring-diagram\"><\/a><\/span>\n<h2>2. Verdrahtungsplan f\u00fcr 24-V-Netzteil<\/h2>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/2-24V-Power-Supply-Wiring-Diagram.webp\" title=\"2-24V-Netzteil-Verdrahtungsdiagramm\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/2-24V-Power-Supply-Wiring-Diagram-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Verdrahtungsplan f\u00fcr ein 2-24V-Netzteil\" ids=\"19160\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/2-24V-Power-Supply-Wiring-Diagram-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/2-24V-Power-Supply-Wiring-Diagram-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/2-24V-Power-Supply-Wiring-Diagram-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/2-24V-Power-Supply-Wiring-Diagram-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/2-24V-Power-Supply-Wiring-Diagram-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/2-24V-Power-Supply-Wiring-Diagram-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/2-24V-Power-Supply-Wiring-Diagram.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>2-24V-Netzteil-Verdrahtungsdiagramm<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<table>\n<thead>\n<tr>\n<th>Kategorie<\/th>\n<th>Nein.<\/th>\n<th>Terminal<\/th>\n<th>Beschreibung<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>AC-Eingang<br \/>(externe Wechselstromversorgung \u2192 24V-Netzteil)<\/td>\n<td>\u2460<\/td>\n<td>Live (L)<\/td>\n<td>AC-Stromanschluss<\/td>\n<\/tr>\n<tr>\n<td> <\/td>\n<td>\u2461<\/td>\n<td>Neutral (N)<\/td>\n<td>AC-R\u00fcckweg<\/td>\n<\/tr>\n<tr>\n<td> <\/td>\n<td>\u2462<\/td>\n<td>Erde (G)<\/td>\n<td>Antistatischer und Sicherheitsschutz<\/td>\n<\/tr>\n<tr>\n<td>Gleichstromausgang<br \/>(24V Stromversorgung \u2192 Pumpe \/ Motor)<\/td>\n<td>\u2463<\/td>\n<td>24 V negativ<\/td>\n<td>Ausgang zur Wei\u00dftinten-Umw\u00e4lzpumpe und zum R\u00fchrmotor (\u2013)<\/td>\n<\/tr>\n<tr>\n<td> <\/td>\n<td>\u2464<\/td>\n<td>24 V positiv<\/td>\n<td>Ausgang zur Wei\u00dftinten-Umw\u00e4lzpumpe und zum R\u00fchrmotor (+)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>In diesem Leitfaden beziehen sich \u2460\u2013\u2464 stets auf die Zahlen in Abb. 2.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-190840434\">\n\n\t<div id=\"col-505855095\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<span class=\"scroll-to\" data-label=\"Scroll to: #3.-fault-inspection-procedure-(check-ac-first,-then-dc)\" data-bullet=\"true\" data-link=\"#3.-fault-inspection-procedure-(check-ac-first,-then-dc)\" data-title=\"3. Fault Inspection Procedure (Check AC First, Then DC)\"><a name=\"3.-fault-inspection-procedure-(check-ac-first,-then-dc)\"><\/a><\/span>\n<h2>3. Vorgehensweise bei der Fehlersuche (Zuerst Wechselstrom, dann Gleichstrom pr\u00fcfen)<\/h2>\n<p><strong>\u26a0 Wichtig:<\/strong> Wenn der externe Wechselstromeingang (\u2460\u2461) keine Spannung liefert, zeigt der Gleichstromausgang des 24-V-Netzteils (\u2463\u2464) 0 V an. Dieser Messwert ist normal und bedeutet nicht, dass das Netzteil defekt ist. \u00dcberpr\u00fcfen Sie immer zuerst den Wechselstromeingang und anschlie\u00dfend den Gleichstromausgang.<\/p>\n<h3>3.1 Sicherheitshinweise<\/h3>\n<ul>\n<li>Messen Sie die Spannungen bei eingeschaltetem Drucker.<\/li>\n<li>Vor dem Austausch des 24V-Netzteils muss die Stromzufuhr vollst\u00e4ndig unterbrochen werden.<\/li>\n<li>Warten Sie eine Minute, nachdem Sie das Netzkabel abgezogen haben. Beginnen Sie dann mit dem Trennen der Kabel.<\/li>\n<li>Tragen Sie isolierende Handschuhe. Ber\u00fchren Sie freiliegende Schaltkreise nicht mit den H\u00e4nden.<\/li>\n<\/ul>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.1-Turning-On-The-MAIN-POWER-Switch.webp\" title=\"3.1 Einschalten des Hauptschalters\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.1-Turning-On-The-MAIN-POWER-Switch-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"3.1 Einschalten des Hauptschalters\" ids=\"19161\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.1-Turning-On-The-MAIN-POWER-Switch-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.1-Turning-On-The-MAIN-POWER-Switch-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.1-Turning-On-The-MAIN-POWER-Switch-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.1-Turning-On-The-MAIN-POWER-Switch-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.1-Turning-On-The-MAIN-POWER-Switch-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.1-Turning-On-The-MAIN-POWER-Switch-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.1-Turning-On-The-MAIN-POWER-Switch.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.1 Einschalten des Hauptschalters<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-522621699\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>3.2 Wechselstromeingangspr\u00fcfung (\u2460\u2013\u2461)<\/h3>\n<p>Multimeter-Modus: ACV 600 V. Bei einem Multimeter mit automatischer Bereichswahl ACV ausw\u00e4hlen.<\/p>\n<p>Messmethode:<\/p>\n<ul>\n<li>Rote Sonde \u2192 \u2460 live<\/li>\n<li>Schwarze Sonde \u2192 \u2461 neutral<\/li>\n<\/ul>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.2-Measuring-The-AC-Input-Of-The-24V-Power-Supply.webp\" title=\"3.2-Messung des Wechselstromeingangs des 24-V-Netzteils\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.2-Measuring-The-AC-Input-Of-The-24V-Power-Supply-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"3.2 Messung des Wechselstromeingangs des 24-V-Netzteils\" ids=\"19143\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.2-Measuring-The-AC-Input-Of-The-24V-Power-Supply-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.2-Measuring-The-AC-Input-Of-The-24V-Power-Supply-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.2-Measuring-The-AC-Input-Of-The-24V-Power-Supply-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.2-Measuring-The-AC-Input-Of-The-24V-Power-Supply-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.2-Measuring-The-AC-Input-Of-The-24V-Power-Supply-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.2-Measuring-The-AC-Input-Of-The-24V-Power-Supply-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.2-Measuring-The-AC-Input-Of-The-24V-Power-Supply.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.2-Messung des Wechselstromeingangs des 24-V-Netzteils<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p><strong>Normalwert: Wechselstrom 200\u2013240 V<\/strong><\/p>\n<p>Das 24-V-Netzteil empf\u00e4ngt Wechselstrom. Gehen Sie zu 3.3 und \u00fcberpr\u00fcfen Sie den Gleichstromausgang.<\/p>\n<p><strong>Abnormaler Wert: 0 V, oder der Messwert ist instabil<\/strong><\/p>\n<p>Es handelt sich nicht um einen Fehler des 24-V-Netzteils. \u00dcberpr\u00fcfen Sie die folgenden Punkte in der angegebenen Reihenfolge:<\/p>\n<ol>\n<li>Kein Strom an der Steckdose<\/li>\n<li>Schutzschalter ausgel\u00f6st<\/li>\n<li>Hauptschalter nicht eingeschaltet<\/li>\n<li>Der obere Netzschalter ist nicht eingeschaltet.<\/li>\n<li>Loses Netzkabel<\/li>\n<li>Lose oder oxidierte Anschl\u00fcsse<\/li>\n<li>Defektes Netzkabel<\/li>\n<\/ol>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-888228771\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>3.3 Gleichstromausgangspr\u00fcfung des 24V-Netzteils (4\u20134)<\/h3>\n<p><strong>Multimeter-Modus:<\/strong> DCV 200 V. Stellen Sie bei einem Multimeter mit automatischer Bereichswahl die Einstellung DCV ein.<\/p>\n<p><strong>Messmethode:<\/strong><\/p>\n<ul>\n<li>Schwarze Sonde \u2192 \u2463 24 V negativ<\/li>\n<li>Rote Sonde \u2192 \u2464 24 V positiv<\/li>\n<\/ul>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply.webp\" title=\"3.3-Messung des Gleichstromausgangs des 24-V-Netzteils\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"3.3-1 Messen des Gleichstromausgangs des 24V-Netzteils\" ids=\"19144\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.3-Messung des Gleichstromausgangs des 24-V-Netzteils<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1770321419\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h4>3.3.1 Auswertung und Ma\u00dfnahmen der Gleichstromausgabe<\/h4>\n<table>\n<thead>\n<tr>\n<th>Messergebnis<\/th>\n<th>Pumpe \/ Motor<\/th>\n<th>Status<\/th>\n<th>Aktion<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>23 \u2013 25 V<\/td>\n<td>L\u00e4uft normal<\/td>\n<td>Das 24V-Netzteil und der Stromversorgungspfad sind in Ordnung.<\/td>\n<td>Der Fehler liegt nicht im 24-V-Stromversorgungspfad. Die Aufgabe in dieser Anleitung ist abgeschlossen. (Siehe Abb. 3.3-2)<\/td>\n<\/tr>\n<tr>\n<td>23 \u2013 25 V<\/td>\n<td>Funktioniert nicht<\/td>\n<td>Die 24-V-Stromversorgung ist in Ordnung. Der Fehler liegt im nachgeschalteten Stromkreis.<\/td>\n<td>Gehen Sie zu 3.3.2. (Siehe Abb. 3.3-2)<\/td>\n<\/tr>\n<tr>\n<td>Der Wechselstromeingang ist normal, und der Messwert betr\u00e4gt 0 V oder weniger als 23 V.<\/td>\n<td>Funktioniert nicht<\/td>\n<td>Das 24V-Netzteil hat einen internen Defekt.<\/td>\n<td>Tauschen Sie das 24-V-Netzteil aus. Fahren Sie mit Abschnitt 4 fort. (Siehe Abb. 3.3-3)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-2-Normal-DC-Output-Of-The-24V-Power-Supply.webp\" title=\"3.3-2-Normaler-Gleichstromausgang-des-24V-Netzteils\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-2-Normal-DC-Output-Of-The-24V-Power-Supply-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"3.3-2 Normaler Gleichstromausgang des 24V-Netzteils\" ids=\"19165,19146\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-2-Normal-DC-Output-Of-The-24V-Power-Supply-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-2-Normal-DC-Output-Of-The-24V-Power-Supply-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-2-Normal-DC-Output-Of-The-24V-Power-Supply-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-2-Normal-DC-Output-Of-The-24V-Power-Supply-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-2-Normal-DC-Output-Of-The-24V-Power-Supply-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-2-Normal-DC-Output-Of-The-24V-Power-Supply-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-2-Normal-DC-Output-Of-The-24V-Power-Supply.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.3-2-Normaler-Gleichstromausgang-des-24V-Netzteils<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-3-Abnormal-DC-Output-Of-The-24V-Power-Supply.webp\" title=\"3.3-3-Abnormale Gleichstromausgabe des 24-V-Netzteils\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-3-Abnormal-DC-Output-Of-The-24V-Power-Supply-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"3.3-3 Anomaler Gleichstromausgang des 24V-Netzteils\" ids=\"19165,19146\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-3-Abnormal-DC-Output-Of-The-24V-Power-Supply-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-3-Abnormal-DC-Output-Of-The-24V-Power-Supply-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-3-Abnormal-DC-Output-Of-The-24V-Power-Supply-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-3-Abnormal-DC-Output-Of-The-24V-Power-Supply-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-3-Abnormal-DC-Output-Of-The-24V-Power-Supply-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-3-Abnormal-DC-Output-Of-The-24V-Power-Supply-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-3-Abnormal-DC-Output-Of-The-24V-Power-Supply.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.3-3-Abnormale Gleichstromausgabe des 24-V-Netzteils<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-632195273\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h4>3.3.2 Eingangsspannungspr\u00fcfung an der Wei\u00dftinten-Umw\u00e4lzpumpe \/ am Wei\u00dftinten-R\u00fchrmotor<\/h4>\n<p><strong>Multimeter-Modus:<\/strong> DCV 200 V. Stellen Sie bei einem Multimeter mit automatischer Bereichswahl die Einstellung DCV ein.<\/p>\n<p><strong>Messmethode:<\/strong><\/p>\n<ul>\n<li>Schwarze Sonde \u2192 negativer Eingangsanschluss der Pumpe oder des R\u00fchrmotors<\/li>\n<li>Rote Sonde \u2192 Pluspol der Pumpe oder des R\u00fchrmotors<\/li>\n<\/ul>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-4-Measuring-The-Input-Voltage-At-The-Pump-And-Motor.webp\" title=\"3.3-4-Messung der Eingangsspannung an Pumpe und Motor\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-4-Measuring-The-Input-Voltage-At-The-Pump-And-Motor-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"3.3-4 Messung der Eingangsspannung an Pumpe und Motor\" ids=\"19147\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-4-Measuring-The-Input-Voltage-At-The-Pump-And-Motor-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-4-Measuring-The-Input-Voltage-At-The-Pump-And-Motor-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-4-Measuring-The-Input-Voltage-At-The-Pump-And-Motor-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-4-Measuring-The-Input-Voltage-At-The-Pump-And-Motor-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-4-Measuring-The-Input-Voltage-At-The-Pump-And-Motor-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-4-Measuring-The-Input-Voltage-At-The-Pump-And-Motor-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-4-Measuring-The-Input-Voltage-At-The-Pump-And-Motor.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.3-4-Messung der Eingangsspannung an Pumpe und Motor<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<table>\n<thead>\n<tr>\n<th>Eingangsspannung<\/th>\n<th>Status<\/th>\n<th>Aktion<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>0,0 V<\/td>\n<td>Die Pumpe oder der R\u00fchrmotor erhalten keinen Strom. Das Kabel ist defekt oder der Kontakt oxidiert.<\/td>\n<td>\u00dcberpr\u00fcfen Sie das Kabel. Tauschen Sie das Kabel aus.<\/td>\n<\/tr>\n<tr>\n<td>23 \u2013 25 V, und die Pumpe oder der R\u00fchrmotor funktioniert nicht.<\/td>\n<td>Die Pumpe oder der R\u00fchrmotor ist defekt.<\/td>\n<td>Tauschen Sie die Pumpe oder den R\u00fchrmotor aus.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Tauschen Sie das 24-V-Netzteil nicht aus, wenn der Fehler im Kabel, in der Pumpe oder im R\u00fchrmotor liegt. Die in dieser Anleitung beschriebenen Schritte sind abgeschlossen.<\/strong><\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-111350174\">\n\n\t<div id=\"col-1967883879\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<span class=\"scroll-to\" data-label=\"Scroll to: #4.-24v-power-supply-replacement\" data-bullet=\"true\" data-link=\"#4.-24v-power-supply-replacement\" data-title=\"4. 24V Power Supply Replacement\"><a name=\"4.-24v-power-supply-replacement\"><\/a><\/span>\n<h2>4. Austausch des 24-V-Netzteils<\/h2>\n<p><strong>Voraussetzung:<\/strong> F\u00fchren Sie diesen Abschnitt erst durch, nachdem Abschnitt 3.3.1 gezeigt hat, dass das 24V-Netzteil einen internen Fehler aufweist.<\/p>\n<h3>4.1 Strom aus<\/h3>\n<ol>\n<li>Dr\u00fccken Sie den oberen Netzschalter, um den Drucker auszuschalten. (Siehe Abb. 4.1-1)<\/li>\n<li>Schalten Sie den HAUPT-EIN-\/AUS-Schalter an der R\u00fcckseite des Druckers aus. (Siehe Abb. 4.1-2)<\/li>\n<li>Ziehen Sie den Netzstecker.<\/li>\n<li>Warten Sie eine Minute. Beginnen Sie dann mit dem Trennen der Kabel.<\/li>\n<\/ol>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-1-Top-Power-Switch-Of-The-Printer.webp\" title=\"4.1-1-Oberer-Netzschalter-des-Druckers\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-1-Top-Power-Switch-Of-The-Printer-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"4.1-1 Oberer Netzschalter des Druckers\" ids=\"19148,19149\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-1-Top-Power-Switch-Of-The-Printer-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-1-Top-Power-Switch-Of-The-Printer-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-1-Top-Power-Switch-Of-The-Printer-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-1-Top-Power-Switch-Of-The-Printer-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-1-Top-Power-Switch-Of-The-Printer-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-1-Top-Power-Switch-Of-The-Printer-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-1-Top-Power-Switch-Of-The-Printer.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.1-1-Oberer-Netzschalter-des-Druckers<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-2-Turning-Off-The-MAIN-POWER-Switch.webp\" title=\"4.1-2-Ausschalten des Hauptschalters\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-2-Turning-Off-The-MAIN-POWER-Switch-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"4.1-2 Ausschalten des Hauptschalters\" ids=\"19148,19149\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-2-Turning-Off-The-MAIN-POWER-Switch-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-2-Turning-Off-The-MAIN-POWER-Switch-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-2-Turning-Off-The-MAIN-POWER-Switch-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-2-Turning-Off-The-MAIN-POWER-Switch-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-2-Turning-Off-The-MAIN-POWER-Switch-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-2-Turning-Off-The-MAIN-POWER-Switch-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.1-2-Turning-Off-The-MAIN-POWER-Switch.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.1-2-Ausschalten des Hauptschalters<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1458409876\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>4.2 Entfernen Sie das alte 24-V-Netzteil<\/h3>\n<h4>4.2.1 Entfernen der R\u00fcckwand<\/h4>\n<ol>\n<li>Hebeln Sie die wei\u00dfen Kunststoffabdeckungsstopfen auf beiden Seiten der R\u00fcckwand vorsichtig heraus.<\/li>\n<li>Ziehen Sie das Netzwerkkabel ab. (Siehe Abb. 4.2-1)<\/li>\n<li>Entfernen Sie die Schrauben der R\u00fcckwand. (Siehe Abb. 4.2-2)<\/li>\n<li>Den L\u00fcfterkabel abziehen. Die R\u00fcckwand entfernen. (Siehe Abb. 4.2-3)<\/li>\n<\/ol>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-1-Removing-The-Plastic-Cover-Plugs-And-The-Network-Cable.webp\" title=\"4.2-1-Entfernen der Kunststoffabdeckung, Stecker und Netzwerkkabel\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-1-Removing-The-Plastic-Cover-Plugs-And-The-Network-Cable-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"4.2-1 Entfernen der Kunststoffabdeckungsstecker und des Netzwerkkabels\" ids=\"19150,19151,19152\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-1-Removing-The-Plastic-Cover-Plugs-And-The-Network-Cable-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-1-Removing-The-Plastic-Cover-Plugs-And-The-Network-Cable-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-1-Removing-The-Plastic-Cover-Plugs-And-The-Network-Cable-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-1-Removing-The-Plastic-Cover-Plugs-And-The-Network-Cable-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-1-Removing-The-Plastic-Cover-Plugs-And-The-Network-Cable-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-1-Removing-The-Plastic-Cover-Plugs-And-The-Network-Cable-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-1-Removing-The-Plastic-Cover-Plugs-And-The-Network-Cable.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.2-1-Entfernen der Kunststoffabdeckung, Stecker und Netzwerkkabel<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-2-Removing-The-Screws-Of-The-Back-Panel.webp\" title=\"4.2-2-Entfernen der Schrauben der R\u00fcckwand\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-2-Removing-The-Screws-Of-The-Back-Panel-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"4.2-2 Entfernen der Schrauben der R\u00fcckwand\" ids=\"19150,19151,19152\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-2-Removing-The-Screws-Of-The-Back-Panel-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-2-Removing-The-Screws-Of-The-Back-Panel-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-2-Removing-The-Screws-Of-The-Back-Panel-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-2-Removing-The-Screws-Of-The-Back-Panel-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-2-Removing-The-Screws-Of-The-Back-Panel-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-2-Removing-The-Screws-Of-The-Back-Panel-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-2-Removing-The-Screws-Of-The-Back-Panel.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.2-2-Entfernen der Schrauben der R\u00fcckwand<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-3-Disconnecting-The-Cooling-Fan-Cable.webp\" title=\"4.2-3-Abtrennen des L\u00fcfterkabels\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-3-Disconnecting-The-Cooling-Fan-Cable-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"4.2-3 Abklemmen des L\u00fcfterkabels\" ids=\"19150,19151,19152\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-3-Disconnecting-The-Cooling-Fan-Cable-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-3-Disconnecting-The-Cooling-Fan-Cable-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-3-Disconnecting-The-Cooling-Fan-Cable-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-3-Disconnecting-The-Cooling-Fan-Cable-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-3-Disconnecting-The-Cooling-Fan-Cable-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-3-Disconnecting-The-Cooling-Fan-Cable-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-3-Disconnecting-The-Cooling-Fan-Cable.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.2-3-Abtrennen des L\u00fcfterkabels<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1334798659\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h4>4.2.2 Kabel trennen<\/h4>\n<ol>\n<li>Fotografieren Sie die Verkabelung, solange alle Kabel noch angeschlossen sind. Verwenden Sie das Foto, um jedes Kabel korrekt wieder anzuschlie\u00dfen. (Siehe Abb. 4.2-4)<\/li>\n<li>L\u00f6sen Sie die Klemmschrauben \u2460\u2013\u2464 der Reihe nach. Siehe Abb. 2.<\/li>\n<li>Ziehen Sie die Kabel nacheinander heraus.<\/li>\n<\/ol>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-4-Wiring-Record-Of-The-24V-Power-Supply.webp\" title=\"4.2-4-Verdrahtungsprotokoll-des-24V-Netzteils\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-4-Wiring-Record-Of-The-24V-Power-Supply-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"4.2-4 Verdrahtungsprotokoll des 24V-Netzteils\" ids=\"19153\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-4-Wiring-Record-Of-The-24V-Power-Supply-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-4-Wiring-Record-Of-The-24V-Power-Supply-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-4-Wiring-Record-Of-The-24V-Power-Supply-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-4-Wiring-Record-Of-The-24V-Power-Supply-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-4-Wiring-Record-Of-The-24V-Power-Supply-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-4-Wiring-Record-Of-The-24V-Power-Supply-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-4-Wiring-Record-Of-The-24V-Power-Supply.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.2-4-Verdrahtungsprotokoll-des-24V-Netzteils<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1900710152\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h4>4.2.3 Die Befestigungsschrauben entfernen<\/h4>\n<ol>\n<li>Die Befestigungsschraube \u2460 entfernen.<\/li>\n<li>Die Befestigungsschraube \u2461 l\u00f6sen. Siehe Abb. 4.2-5.<\/li>\n<li>Das alte 24V-Netzteil muss entfernt werden. Siehe Abb. 4.2-6.<\/li>\n<\/ol>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-5-Removing-The-Fixing-Screw-And-Locating-Screw.webp\" title=\"4.2-5-Entfernen der Befestigungsschraube und Positionieren der Schraube\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-5-Removing-The-Fixing-Screw-And-Locating-Screw-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"4.2-5 Entfernen der Befestigungsschraube und der Positionierungsschraube\" ids=\"19154,19155\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-5-Removing-The-Fixing-Screw-And-Locating-Screw-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-5-Removing-The-Fixing-Screw-And-Locating-Screw-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-5-Removing-The-Fixing-Screw-And-Locating-Screw-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-5-Removing-The-Fixing-Screw-And-Locating-Screw-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-5-Removing-The-Fixing-Screw-And-Locating-Screw-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-5-Removing-The-Fixing-Screw-And-Locating-Screw-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-5-Removing-The-Fixing-Screw-And-Locating-Screw.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.2-5-Entfernen der Befestigungsschraube und Positionieren der Schraube<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-6-The-Removed-24V-Power-Supply.webp\" title=\"4.2-6-Das-entfernte-24V-Netzteil\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-6-The-Removed-24V-Power-Supply-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"4.2-6 Das entfernte 24V-Netzteil\" ids=\"19154,19155\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-6-The-Removed-24V-Power-Supply-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-6-The-Removed-24V-Power-Supply-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-6-The-Removed-24V-Power-Supply-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-6-The-Removed-24V-Power-Supply-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-6-The-Removed-24V-Power-Supply-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-6-The-Removed-24V-Power-Supply-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/4.2-6-The-Removed-24V-Power-Supply.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.2-6-Das-entfernte-24V-Netzteil<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1683038945\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>4.3 Installieren Sie das neue 24V-Netzteil<\/h3>\n<h4>4.3.1 Modell best\u00e4tigen<\/h4>\n<p>Vergleichen Sie die Modellbezeichnungen der neuen und alten 24-V-Netzteile. Vergewissern Sie sich, dass beide Modelle identisch sind.<\/p>\n<h4>4.3.2 Montieren Sie das 24-V-Netzteil<\/h4>\n<ol>\n<li>Richten Sie die Befestigungsl\u00f6cher aus. Setzen Sie das 24-V-Netzteil in die Befestigungsschrauben ein.<\/li>\n<li>Die Befestigungsschraube und die Positionierschraube festziehen. (Siehe Abb. 4.2-5)<\/li>\n<\/ol>\n<h4>4.3.3 Kabel anschlie\u00dfen<\/h4>\n<ol>\n<li>Schlie\u00dfen Sie die Kabel \u2460\u2013\u2464 der Reihe nach an. Folgen Sie Abb. 2.<\/li>\n<li>Vergewissern Sie sich, dass jedes Kabel vollst\u00e4ndig eingeschoben ist.<\/li>\n<li>Vergleichen Sie die Verkabelung mit dem Foto aus Abschnitt 4.2.2. Pr\u00fcfen Sie, ob alle Kabel an der richtigen Stelle sind und ob kein Kabel lose ist.<\/li>\n<li>Alle Klemmschrauben festziehen.<\/li>\n<\/ol>\n<h4>4.3.4 R\u00fcckwand wieder einbauen<\/h4>\n<ol>\n<li>Schlie\u00dfen Sie das L\u00fcfterkabel an. (Siehe Abb. 4.2-3)<\/li>\n<li>Die R\u00fcckwand ausrichten. Die R\u00fcckwand montieren. Die Schrauben festziehen. (Siehe Abb. 4.2-2)<\/li>\n<li>Schlie\u00dfen Sie das Netzwerkkabel an. (Siehe Abb. 4.2-1)<\/li>\n<li>Bringen Sie die wei\u00dfen Kunststoff-Abdeckstopfen auf beiden Seiten an.<\/li>\n<\/ol>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-446687538\">\n\n\t<div id=\"col-776669455\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<span class=\"scroll-to\" data-label=\"Scroll to: #5.-power-on-check\" data-bullet=\"true\" data-link=\"#5.-power-on-check\" data-title=\"5. Power-On Check\"><a name=\"5.-power-on-check\"><\/a><\/span>\n<h2>5. Einschaltpr\u00fcfung<\/h2>\n<h3>5.1 \u00dcberpr\u00fcfen Sie alle Kabel nochmals auf lose Verbindungen und verpolte Anschl\u00fcsse.<\/h3>\n<h3>5.2 Schlie\u00dfen Sie das Netzkabel an. Schalten Sie den Hauptschalter (MAIN POWER) an der R\u00fcckseite des Druckers ein. (Siehe Abb. 3.1)<\/h3>\n<h3>5.3 Dr\u00fccken Sie den oberen Netzschalter. Die Kontrollleuchte leuchtet auf. (Siehe Abb. 5.3)<\/h3>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.3-Pressing-The-Top-Power-Switch-Top-View.webp\" title=\"5.3 Dr\u00fccken des oberen Netzschalters \u2013 Draufsicht\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.3-Pressing-The-Top-Power-Switch-Top-View-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"5.3 Dr\u00fccken des oberen Netzschalters (Draufsicht)\" ids=\"19156\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.3-Pressing-The-Top-Power-Switch-Top-View-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.3-Pressing-The-Top-Power-Switch-Top-View-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.3-Pressing-The-Top-Power-Switch-Top-View-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.3-Pressing-The-Top-Power-Switch-Top-View-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.3-Pressing-The-Top-Power-Switch-Top-View-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.3-Pressing-The-Top-Power-Switch-Top-View-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.3-Pressing-The-Top-Power-Switch-Top-View.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>5.3 Dr\u00fccken des oberen Netzschalters \u2013 Draufsicht<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<h3>5.4 Best\u00e4tigung des endg\u00fcltigen Status<\/h3>\n<p>Nachdem alle Kabel angeschlossen und der Drucker eingeschaltet ist, \u00fcberpr\u00fcfen Sie bitte die folgenden drei Punkte:<\/p>\n<ol>\n<li>Die Kontrollleuchte des 24V-Netzteils bleibt an.<\/li>\n<li>Die Messwerte an den Punkten \u2463\u2013\u2464 betragen 23\u201325 V. Verwenden Sie das Multimeter im DCV 200 V-Modus.<\/li>\n<li>Die Umw\u00e4lzpumpe f\u00fcr die wei\u00dfe Tinte und der R\u00fchrmotor f\u00fcr die wei\u00dfe Tinte laufen wieder an.<\/li>\n<\/ol>\n<p><strong>\u2705 Normal:<\/strong> Alle drei Bedingungen sind erf\u00fcllt. Der Austausch ist abgeschlossen. (Siehe Abb. 5.4-1)<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1057614369\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-1-Normal-Status-After-Replacement.webp\" title=\"5.4-1-Normalzustand-nach-dem-Austausch\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-1-Normal-Status-After-Replacement-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"5.4-1 Normalzustand nach dem Austausch\" ids=\"19157\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-1-Normal-Status-After-Replacement-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-1-Normal-Status-After-Replacement-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-1-Normal-Status-After-Replacement-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-1-Normal-Status-After-Replacement-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-1-Normal-Status-After-Replacement-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-1-Normal-Status-After-Replacement-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-1-Normal-Status-After-Replacement.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>5.4-1-Normalzustand-nach-dem-Austausch<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p><strong><b>\u274c <\/b><\/strong><strong><b>\u00a0<\/b>Abnormal:<\/strong> Die Kontrollleuchte ist aus, blinkt unregelm\u00e4\u00dfig oder der Messwert betr\u00e4gt 0,0 V. (Siehe Abb. 5.4-2)<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-2-Abnormal-Status-After-Replacement.webp\" title=\"5.4-2-Abnormaler-Status-Nach-dem-Austausch\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-2-Abnormal-Status-After-Replacement-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"5.4-2 Abnormaler Zustand nach dem Austausch\" ids=\"19158\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-2-Abnormal-Status-After-Replacement-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-2-Abnormal-Status-After-Replacement-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-2-Abnormal-Status-After-Replacement-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-2-Abnormal-Status-After-Replacement-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-2-Abnormal-Status-After-Replacement-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-2-Abnormal-Status-After-Replacement-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/5.4-2-Abnormal-Status-After-Replacement.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>5.4-2-Abnormaler-Status-Nach-dem-Austausch<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>\u00dcberpr\u00fcfen Sie die Verkabelung erneut. Sollte die Verkabelung korrekt sein und die Messwerte weiterhin fehlerhaft, wenden Sie sich bitte an den technischen Support von LINKO.<\/p>\n<p><strong>\u26a0 Die Spannung ist normal, aber die Pumpe oder der R\u00fchrmotor funktionieren trotzdem nicht:<\/strong> Der Fehler liegt nicht am 24-V-Netzteil. Gehen Sie zur\u00fcck zu Abschnitt 3.3.2 und messen Sie die Eingangsspannung an der Pumpe und am R\u00fchrmotor.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-120338129\">\n\n\t<div id=\"col-1114328556\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<div class=\"is-divider divider clearfix\" style=\"max-width:1200px;height:2px;\"><\/div>\n<p><span style=\"font-size: 115%;\"><strong>Technischer Support von LINKO<\/strong><\/span><br \/><span style=\"font-size: 95%;\"><span style=\"color: #4f4f4f;\"><span style=\"color: #333333;\">E-Mail:<\/span> <\/span><a href=\"mailto:support@dtflinko.com\">support@dtflinko.com<\/a><\/span><br \/><span style=\"font-size: 95%;\"><span style=\"color: #4f4f4f;\"><span style=\"color: #333333;\">Website:<\/span> <\/span><a href=\"https:\/\/www.dtflinko.com\/de\/\">www.dtflinko.com<\/a><\/span><\/p>\n<p><span style=\"font-size: 85%; color: #808080;\">\u00a9 2026 LINKO Technisches Team. Alle Rechte vorbehalten.<\/span><br \/><span style=\"font-size: 85%; color: #808080;\">Die unbefugte Vervielf\u00e4ltigung oder \u00c4nderung dieses Dokuments ist untersagt.<\/span><\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_593628082 {\n  padding-top: 40px;\n  padding-bottom: 40px;\n}\n@media (min-width:850px) {\n  #section_593628082 {\n    padding-top: 60px;\n    padding-bottom: 60px;\n  }\n}\n<\/style>\n\t<\/section>","protected":false},"excerpt":{"rendered":"","protected":false},"author":3,"featured_media":19144,"parent":15609,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-blank.php","meta":{"footnotes":""},"class_list":["post-19162","page","type-page","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>KM-602 24V Power Supply Inspection and Replacement Guide | LINKO DTF Printer<\/title>\n<meta name=\"description\" content=\"Test the AC input and the DC output of the 24V power supply on the LINKO KM-602 DTF printer, then replace the 24V Power Supply when the white ink pump or white ink circulation pumpstops working.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.dtflinko.com\/de\/technische-dienstleistungen\/reparatur-des-technischen-betriebs-des-druckers\/leitfaden-zur-inspektion-und-zum-austausch-des-24-v-netzteils-km-602\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"KM-602 24V Power Supply Inspection and Replacement Guide | LINKO DTF Printer\" \/>\n<meta property=\"og:description\" content=\"Test the AC input and the DC output of the 24V power supply on the LINKO KM-602 DTF printer, then replace the 24V Power Supply when the white ink pump or white ink circulation pumpstops working.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.dtflinko.com\/de\/technische-dienstleistungen\/reparatur-des-technischen-betriebs-des-druckers\/leitfaden-zur-inspektion-und-zum-austausch-des-24-v-netzteils-km-602\/\" \/>\n<meta property=\"og:site_name\" content=\"LINKO DTF Printer\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/linkoprinter\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-17T06:19:20+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"960\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@linkoprinter\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"1\u00a0Minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/km-602-24v-power-supply-inspection-and-replacement-guide\\\/\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/km-602-24v-power-supply-inspection-and-replacement-guide\\\/\",\"name\":\"KM-602 24V Power Supply Inspection and Replacement Guide | LINKO DTF Printer\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/km-602-24v-power-supply-inspection-and-replacement-guide\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/km-602-24v-power-supply-inspection-and-replacement-guide\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.dtflinko.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply.webp\",\"datePublished\":\"2026-08-17T05:22:02+00:00\",\"dateModified\":\"2026-08-17T06:19:20+00:00\",\"description\":\"Test the AC input and the DC output of the 24V power supply on the LINKO KM-602 DTF printer, then replace the 24V Power Supply when the white ink pump or white ink circulation pumpstops working.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/km-602-24v-power-supply-inspection-and-replacement-guide\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/km-602-24v-power-supply-inspection-and-replacement-guide\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/km-602-24v-power-supply-inspection-and-replacement-guide\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply.webp\",\"contentUrl\":\"https:\\\/\\\/www.dtflinko.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply.webp\",\"width\":1280,\"height\":960,\"caption\":\"3.3-Measuring-The-DC-Output-Of-The-24V-Power-Supply\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/km-602-24v-power-supply-inspection-and-replacement-guide\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.dtflinko.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Support &#038; Technical Services\",\"item\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Printer Technical Operation &amp; Repair\",\"item\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Replace Power Supply- KM-602\uff5c24V Power Supply\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/#website\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/\",\"name\":\"LINKO DTF Printer\",\"description\":\"DTF Printer\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.dtflinko.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/#organization\",\"name\":\"LINKO\",\"alternateName\":\"LINKO DTF PRINTERS MANUFACTURER\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Linko-logo.png\",\"contentUrl\":\"https:\\\/\\\/www.dtflinko.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Linko-logo.png\",\"width\":1000,\"height\":1000,\"caption\":\"LINKO\"},\"image\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/linkoprinter\",\"https:\\\/\\\/x.com\\\/linkoprinter\",\"https:\\\/\\\/www.youtube.com\\\/@LinkoPrinter\",\"https:\\\/\\\/www.instagram.com\\\/linkoprinter\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/dtflinko\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"KM-602 24V Netzteil \u2013 Pr\u00fcf- und Austauschanleitung | LINKO DTF-Drucker","description":"Pr\u00fcfen Sie den Wechselstromeingang und den Gleichstromausgang des 24V-Netzteils am LINKO KM-602 DTF-Drucker. Tauschen Sie das 24V-Netzteil aus, wenn die Wei\u00dftintenpumpe oder die Wei\u00dftintenzirkulationspumpe nicht mehr funktioniert.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.dtflinko.com\/de\/technische-dienstleistungen\/reparatur-des-technischen-betriebs-des-druckers\/leitfaden-zur-inspektion-und-zum-austausch-des-24-v-netzteils-km-602\/","og_locale":"de_DE","og_type":"article","og_title":"KM-602 24V Power Supply Inspection and Replacement Guide | LINKO DTF Printer","og_description":"Test the AC input and the DC output of the 24V power supply on the LINKO KM-602 DTF printer, then replace the 24V Power Supply when the white ink pump or white ink circulation pumpstops working.","og_url":"https:\/\/www.dtflinko.com\/de\/technische-dienstleistungen\/reparatur-des-technischen-betriebs-des-druckers\/leitfaden-zur-inspektion-und-zum-austausch-des-24-v-netzteils-km-602\/","og_site_name":"LINKO DTF Printer","article_publisher":"https:\/\/www.facebook.com\/linkoprinter","article_modified_time":"2026-08-17T06:19:20+00:00","og_image":[{"width":1280,"height":960,"url":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_site":"@linkoprinter","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"1\u00a0Minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/km-602-24v-power-supply-inspection-and-replacement-guide\/","url":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/km-602-24v-power-supply-inspection-and-replacement-guide\/","name":"KM-602 24V Netzteil \u2013 Pr\u00fcf- und Austauschanleitung | LINKO DTF-Drucker","isPartOf":{"@id":"https:\/\/www.dtflinko.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/km-602-24v-power-supply-inspection-and-replacement-guide\/#primaryimage"},"image":{"@id":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/km-602-24v-power-supply-inspection-and-replacement-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply.webp","datePublished":"2026-08-17T05:22:02+00:00","dateModified":"2026-08-17T06:19:20+00:00","description":"Pr\u00fcfen Sie den Wechselstromeingang und den Gleichstromausgang des 24V-Netzteils am LINKO KM-602 DTF-Drucker. Tauschen Sie das 24V-Netzteil aus, wenn die Wei\u00dftintenpumpe oder die Wei\u00dftintenzirkulationspumpe nicht mehr funktioniert.","breadcrumb":{"@id":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/km-602-24v-power-supply-inspection-and-replacement-guide\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/km-602-24v-power-supply-inspection-and-replacement-guide\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/km-602-24v-power-supply-inspection-and-replacement-guide\/#primaryimage","url":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply.webp","contentUrl":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/08\/3.3-1-Measuring-The-DC-Output-Of-The-24V-Power-Supply.webp","width":1280,"height":960,"caption":"3.3-Measuring-The-DC-Output-Of-The-24V-Power-Supply"},{"@type":"BreadcrumbList","@id":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/km-602-24v-power-supply-inspection-and-replacement-guide\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.dtflinko.com\/"},{"@type":"ListItem","position":2,"name":"Support &#038; Technical Services","item":"https:\/\/www.dtflinko.com\/technical-services\/"},{"@type":"ListItem","position":3,"name":"Printer Technical Operation &amp; Repair","item":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/"},{"@type":"ListItem","position":4,"name":"Replace Power Supply- KM-602\uff5c24V Power Supply"}]},{"@type":"WebSite","@id":"https:\/\/www.dtflinko.com\/#website","url":"https:\/\/www.dtflinko.com\/","name":"LINKO DTF Drucker","description":"DTF Drucker","publisher":{"@id":"https:\/\/www.dtflinko.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.dtflinko.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.dtflinko.com\/#organization","name":"LINKO","alternateName":"LINKO DTF PRINTERS MANUFACTURER","url":"https:\/\/www.dtflinko.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.dtflinko.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/09\/Linko-logo.png","contentUrl":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/09\/Linko-logo.png","width":1000,"height":1000,"caption":"LINKO"},"image":{"@id":"https:\/\/www.dtflinko.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/linkoprinter","https:\/\/x.com\/linkoprinter","https:\/\/www.youtube.com\/@LinkoPrinter","https:\/\/www.instagram.com\/linkoprinter\/","https:\/\/www.linkedin.com\/company\/dtflinko\/"]}]}},"_links":{"self":[{"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/pages\/19162","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/comments?post=19162"}],"version-history":[{"count":13,"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/pages\/19162\/revisions"}],"predecessor-version":[{"id":19195,"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/pages\/19162\/revisions\/19195"}],"up":[{"embeddable":true,"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/pages\/15609"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/media\/19144"}],"wp:attachment":[{"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/media?parent=19162"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}