{"id":16791,"date":"2025-12-25T23:18:08","date_gmt":"2025-12-26T07:18:08","guid":{"rendered":"https:\/\/www.dtflinko.com\/?page_id=16791"},"modified":"2026-02-01T23:54:47","modified_gmt":"2026-02-02T07:54:47","slug":"k60-serie-36v-netzteil-inspektions-und-austauschleitfaden","status":"publish","type":"page","link":"https:\/\/www.dtflinko.com\/de\/technical-services\/printer-technical-operation-repair\/k60-series-36v-power-supply-inspection-replacement-guide\/","title":{"rendered":"K60-Serie | Leitfaden zur Pr\u00fcfung und zum Austausch von 36-V-Netzteilen"},"content":{"rendered":"<section class=\"section\" id=\"section_269147646\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row\"  id=\"row-371509940\">\n\n\t<div id=\"col-841224883\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div id=\"text-3838349961\" class=\"text\">\n\t\t\n<h1>K60-Serie | Leitfaden zur Pr\u00fcfung und zum Austausch von 36-V-Netzteilen<\/h1>\n\t\t\n<style>\n#text-3838349961 {\n  text-align: center;\n}\n<\/style>\n\t<\/div>\n\t\n<p>Anwendbare Modelle: LINKO K60 Serie DTF-Drucker<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1307238218\">\n\n\t<div id=\"col-126267299\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<span class=\"scroll-to\" data-label=\"Scroll to: #power-supply-function-description\" data-bullet=\"true\" data-link=\"#power-supply-function-description\" data-title=\"Power Supply Function Description\"><a name=\"power-supply-function-description\"><\/a><\/span>\n<h2>1. Funktionsbeschreibung der Stromversorgung<\/h2>\n<p>Der Drucker enth\u00e4lt mehrere Netzteile. Jedes Netzteil ist so ausgelegt, dass es ein bestimmtes System innerhalb des Druckers mit Strom versorgt.<\/p>\n<p><strong>36V-Netzteil:<\/strong><\/p>\n<p>Versorgt die folgenden beiden Teile mit Gleichstrom (36 V):<\/p>\n<ul>\n<li>X-Achsen-Motor (direkt mit Strom versorgt)<\/li>\n<li>Y-Achsen-Treiber (der Treiber steuert und treibt den Y-Achsen-Motor an)<\/li>\n<\/ul>\n<p><strong>Andere Netzteile:<\/strong><\/p>\n<ul>\n<li><strong>24V-Netzteil:<\/strong> Versorgt die <span style=\"color: #003366;\">Wei\u00dftinten-Umw\u00e4lzpumpe und Wei\u00dftinten-R\u00fchrmotor.<\/span><\/li>\n<li><strong>Mehrfachausgangs-Leistungsmodul:<\/strong> Liefert mehrere Gleichspannungen (42 V \/ 36 V \/ 24 V) an <span style=\"color: #003366;\">Hauptplatine, Schlittenplatine, Vakuumplattform, L\u00fcfter, Bildschirm, elektrische Medienhebestange<\/span>, usw.<\/li>\n<\/ul>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Overview.webp\" title=\"1-Netzteil-\u00dcbersicht\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Overview-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"\u00dcbersicht der Stromversorgung\" ids=\"16795\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Overview-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Overview-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Overview-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Overview-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Overview-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Overview-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Overview.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>1-Netzteil-\u00dcbersicht<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1145427166\">\n\n\t<div id=\"col-854800895\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<span class=\"scroll-to\" data-label=\"Scroll to: #36v-power-supply-wiring-diagram\" data-bullet=\"true\" data-link=\"#36v-power-supply-wiring-diagram\" data-title=\"36V Power Supply Wiring Diagram\"><a name=\"36v-power-supply-wiring-diagram\"><\/a><\/span>\n<h2>2. Verdrahtungsplan f\u00fcr 36-V-Netzteil<\/h2>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/36V-Power-Supply-Wiring-Diagram.webp\" title=\"2-1-36V-Netzteil-Verdrahtungsdiagramm\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/36V-Power-Supply-Wiring-Diagram-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Verdrahtungsplan f\u00fcr ein 36-V-Netzteil\" ids=\"16796,17509\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/36V-Power-Supply-Wiring-Diagram-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/36V-Power-Supply-Wiring-Diagram-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/36V-Power-Supply-Wiring-Diagram-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/36V-Power-Supply-Wiring-Diagram-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/36V-Power-Supply-Wiring-Diagram-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/36V-Power-Supply-Wiring-Diagram-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/36V-Power-Supply-Wiring-Diagram.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>2-1-36V-Netzteil-Verdrahtungsdiagramm<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-36V-Power-Supply-Wiring-Diagram-Chinese.webp\" title=\"2-2-36V-Netzteil-Verdrahtungsdiagramm (Chinesisch)\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-36V-Power-Supply-Wiring-Diagram-Chinese-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"K60-Serie-36V-Netzteil-Verdrahtungsdiagramm-Chinesische-Version\" ids=\"16796,17509\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-36V-Power-Supply-Wiring-Diagram-Chinese-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-36V-Power-Supply-Wiring-Diagram-Chinese-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-36V-Power-Supply-Wiring-Diagram-Chinese-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-36V-Power-Supply-Wiring-Diagram-Chinese-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-36V-Power-Supply-Wiring-Diagram-Chinese-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-36V-Power-Supply-Wiring-Diagram-Chinese-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/02\/2-2-36V-Power-Supply-Wiring-Diagram-Chinese.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>2-2-36V-Netzteil-Verdrahtungsdiagramm (Chinesisch)<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-121893674\">\n\n\t<div id=\"col-1626570279\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<table class=\"power-interface-table\">\n<thead>\n<tr>\n<th>Kategorie<\/th>\n<th>Nein.<\/th>\n<th>Schnittstelle<\/th>\n<th>Beschreibung<\/th>\n<th>AUSWEIS<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td rowspan=\"3\"><strong>AC-Eingang <\/strong>(Externe Stromversorgung \u2192 36V Netzteil)<\/td>\n<td>\u2460<\/td>\n<td>Stromkabel (L)<\/td>\n<td>AC-Stromanschluss<\/td>\n<td>AC-L1<\/td>\n<\/tr>\n<tr>\n<td>\u2461<\/td>\n<td>Neutralleiter (N)<\/td>\n<td>Wechselstromr\u00fcckf\u00fchrung<\/td>\n<td>AC-N1<\/td>\n<\/tr>\n<tr>\n<td>\u2462<\/td>\n<td>Erdungsdraht (G)<\/td>\n<td>Antistatische und sichere Erdung<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\"><strong>Gleichstromausgang <\/strong>(36V Netzteil \u2192 X-Achsen-Motor \/ Y-Achsen-Treiber)<\/td>\n<td>\u2463<\/td>\n<td>36V negativ<\/td>\n<td>Ausgang zum Y-Achsen-Treiber (\u2013)<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>\u2464<\/td>\n<td>36V negativ<\/td>\n<td>Ausgang zum X-Achsen-Motor (\u2013)<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>\u2465<\/td>\n<td>36V positiv<\/td>\n<td>Ausgang zum Y-Achsen-Treiber (+)<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>\u2466<\/td>\n<td>36V positiv<\/td>\n<td>Ausgang zum X-Achsen-Motor (+)<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-833288566\">\n\n\t<div id=\"col-1099922986\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<span class=\"scroll-to\" data-label=\"Scroll to: #fault-inspection-procedure\" data-bullet=\"true\" data-link=\"#fault-inspection-procedure\" data-title=\"Fault Inspection Procedure\"><a name=\"fault-inspection-procedure\"><\/a><\/span>\n<h2>3. Fehlerinspektionsverfahren<\/h2>\n<p>(Richtige Reihenfolge: Zuerst Wechselstrom pr\u00fcfen, dann Gleichstrom)<\/p>\n<p><strong>\u26a0 Wichtiger Logikhinweis:<\/strong><br \/>Wenn am externen Stromeingang (\u2460\u2461) keine Spannung anliegt, zeigen die Ausg\u00e4nge (\u2463\u2465) und (\u2464\u2466) des 36V-Netzteils 0V an.<br \/>Das ist normal und deutet nicht auf ein defektes Netzteil hin.<br \/>Pr\u00fcfen Sie immer zuerst den externen Stromeingang, bevor Sie den Ausgang des 36V-Netzteils pr\u00fcfen.<\/p>\n<h3>3.1 Sicherheitswarnung<\/h3>\n<p>Wichtig (Betriebsregeln):<\/p>\n<ul>\n<li><strong>Spannungsmessung<\/strong> muss durchgef\u00fchrt werden mit <strong>Strom einschalten<\/strong>.<\/li>\n<li>Beim Austausch des Netzteils muss die Stromzufuhr unterbrochen sein.<\/li>\n<\/ul>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On.webp\" title=\"3.1-Einschalten\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Einschalten\" ids=\"16433\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Power-On.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.1-Einschalten<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>\u26a0 Tragen Sie isolierende Handschuhe und vermeiden Sie den Kontakt mit freiliegenden Schaltkreisen.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-776858639\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>3.2 Externe Stromversorgung pr\u00fcfen (Wechselstromeingang) (\u2460\u2013\u2461)<\/h3>\n<p><strong>Multimeter-Modus:<\/strong> Wechselstrom 600 V<br \/><strong>Messmethode:<\/strong><\/p>\n<ul>\n<li>Rote Sonde \u2192 \u2460 (AC-L1) Stromf\u00fchrender Draht<\/li>\n<li>Schwarze Sonde \u2192 \u2461 (AC-N1) Neutralleiter<\/li>\n<\/ul>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/External-Power-Input-Measurement.webp\" title=\"3.2-1-Externe-Leistungsaufnahme-Messung\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/External-Power-Input-Measurement-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Messung der externen Leistungsaufnahme\" ids=\"16798\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/External-Power-Input-Measurement-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/External-Power-Input-Measurement-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/External-Power-Input-Measurement-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/External-Power-Input-Measurement-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/External-Power-Input-Measurement-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/External-Power-Input-Measurement-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/External-Power-Input-Measurement.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.2-1-Externe-Leistungsaufnahme-Messung<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p><strong>Normalwert: Wechselstrom 200\u2013240 V<\/strong><br \/>\u2192 Das Netzteil ist mit Eingangsspannung versorgt. \u00dcberpr\u00fcfen Sie weiterhin den 36-V-Ausgang.<br \/><strong>Abnormal: 0 V oder instabile Spannung<\/strong><br \/>\u2192 Kein Fehler im Netzteil. Bitte pr\u00fcfen Sie Folgendes:<\/p>\n<ul>\n<li>Kabeltrennung<\/li>\n<li>Hauptschalter nicht eingeschaltet<\/li>\n<li>Not-Aus-Schalter nicht gel\u00f6st<\/li>\n<li>Kein Strom an der Steckdose<\/li>\n<li>Loses Netzkabel<\/li>\n<li>Lose oder oxidierte Anschl\u00fcsse<\/li>\n<li>Kabelbruch<\/li>\n<\/ul>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-982318944\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>3.3 Y-Achsen-Treiber pr\u00fcfen (DC-Ausgang) (\u2463\u2465)<\/h3>\n<p><strong>Multimeter-Modus:<\/strong> Gleichspannung 200 V<br \/><strong>Messpunkte<\/strong> (Siehe Abbildung 3.3):<\/p>\n<ul>\n<li>Rote Sonde \u2192 \u2465 Y-Achsen-Treiber (+)<\/li>\n<li>Schwarze Sonde \u2192 \u2463 Y-Achsen-Treiber (\u2013)<\/li>\n<\/ul>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Measurement-Y-Axis-Driver.webp\" title=\"3.3-DC-Ausgangsmessung-Y-Achsen-Treiber\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Measurement-Y-Axis-Driver-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"DC-Ausgangsmessung Y-Achsen-Treiber\" ids=\"16800\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Measurement-Y-Axis-Driver-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Measurement-Y-Axis-Driver-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Measurement-Y-Axis-Driver-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Measurement-Y-Axis-Driver-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Measurement-Y-Axis-Driver-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Measurement-Y-Axis-Driver-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Measurement-Y-Axis-Driver.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.3-DC-Ausgangsmessung-Y-Achsen-Treiber<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<h4>3.3.1 Auswertungstabelle der DC-Ausgangsergebnisse des Y-Achsen-Treibers<\/h4>\n<table>\n<thead>\n<tr>\n<th>Messergebnis<\/th>\n<th>Statusurteil<\/th>\n<th>Aktion<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>35\u201337 V (\u00b110%) und der Y-Achsen-Treiber funktionieren<\/td>\n<td>\u2705 Gleichstromausgang normal<\/td>\n<td>Die Stromversorgung funktioniert einwandfrei. Kein Austausch erforderlich.<\/td>\n<\/tr>\n<tr>\n<td>35\u201337 V (\u00b110%), aber der Y-Achsen-Treiber funktioniert nicht.<\/td>\n<td>\u2705 Stromversorgung funktioniert einwandfrei \u2192 Fehler liegt nicht an der Stromversorgung<\/td>\n<td>\u00dcberpr\u00fcfen Sie weiterhin die Eingangsspannung des Y-Achsen-Treibers.<\/td>\n<\/tr>\n<tr>\n<td>0 V oder deutlich zu niedrig (Wechselstromeingang normal best\u00e4tigt)<\/td>\n<td>\u274c Interner Stromversorgungsfehler<\/td>\n<td>Ersetzen Sie das 36V-Netzteil<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Normal.webp\" title=\"3.3.1-1-Stromversorgung-Normal\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Normal-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Stromversorgung normal\" ids=\"16801\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Normal-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Normal-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Normal-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Normal-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Normal-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Normal-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Normal.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.3.1-1-Stromversorgung-Normal<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Abnormal.webp\" title=\"3.3.1-2-Stromversorgungsst\u00f6rung\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Abnormal-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Stromversorgungsproblem\" ids=\"16802\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Abnormal-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Abnormal-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Abnormal-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Abnormal-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Abnormal-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Abnormal-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Abnormal.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.3.1-2-Stromversorgungsst\u00f6rung<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<h4>3.3.2 Weitere \u00dcberpr\u00fcfung der Eingangsspannung des Y-Achsen-Treibers<\/h4>\n<table>\n<thead>\n<tr>\n<th>Eingangsspannung<\/th>\n<th>Fehlerbeurteilung<\/th>\n<th>Aktion<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>0,0 V<\/td>\n<td>Der Y-Achsen-Treiber erh\u00e4lt keine Stromversorgung \u2192 Kabelbruch \/ Oxidation der Anschl\u00fcsse<\/td>\n<td>Pr\u00fcfen Sie den Zustand des Kabels und tauschen Sie es gegebenenfalls aus.<\/td>\n<\/tr>\n<tr>\n<td>35\u201337 V (\u00b110%), aber der Y-Achsen-Treiber funktioniert nicht.<\/td>\n<td>Ausfall des Y-Achsen-Antriebs<\/td>\n<td>Ersetzen Sie den Y-Achsen-Treiber.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Y-Axis-Driver-Input-Voltage-Measurement.webp\" title=\"3.3.2-Y-Achsen-Treiber-Eingangsspannungsmessung\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Y-Axis-Driver-Input-Voltage-Measurement-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Eingangsspannungsmessung des Y-Achsen-Treibers\" ids=\"16803\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Y-Axis-Driver-Input-Voltage-Measurement-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Y-Axis-Driver-Input-Voltage-Measurement-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Y-Axis-Driver-Input-Voltage-Measurement-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Y-Axis-Driver-Input-Voltage-Measurement-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Y-Axis-Driver-Input-Voltage-Measurement-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Y-Axis-Driver-Input-Voltage-Measurement-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Y-Axis-Driver-Input-Voltage-Measurement.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.3.2-Y-Achsen-Treiber-Eingangsspannungsmessung<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1429026038\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>3.4 X-Achsen-Motor pr\u00fcfen (Gleichstromausgang) (\u2464\u2466)<\/h3>\n<p><strong>Multimeter-Modus:<\/strong> Gleichspannung 200 V<br \/><strong>Messpunkte (siehe Abbildung 3.4):<\/strong><\/p>\n<ul>\n<li>Rote Sonde \u2192 \u2466 X-Achsen-Motor (+)<\/li>\n<li>Schwarze Sonde \u2192 \u2464 X-Achsen-Motor (\u2013)<\/li>\n<\/ul>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Measurement-X-Axis-Motor-.webp\" title=\"3.4-DC-Ausgangsmessung-X-Achsen-Motor \">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Measurement-X-Axis-Motor--500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Gleichstromausgangsmessung X-Achsen-Motor\" ids=\"16804\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Measurement-X-Axis-Motor--500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Measurement-X-Axis-Motor--1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Measurement-X-Axis-Motor--400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Measurement-X-Axis-Motor--768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Measurement-X-Axis-Motor--16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Measurement-X-Axis-Motor--600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/DC-Output-Measurement-X-Axis-Motor-.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.4-DC-Ausgangsmessung-X-Achsen-Motor <\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<h4>3.4.1 Auswertungstabelle der Gleichstromausgangsleistung des X-Achsen-Motors<\/h4>\n<table>\n<thead>\n<tr>\n<th>Messergebnis<\/th>\n<th>Statusurteil<\/th>\n<th>Aktion<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>35\u201337 V (\u00b110%) und der X-Achsen-Motor ist in Betrieb.<\/td>\n<td>\u2705 Gleichstromausgang normal<\/td>\n<td>Die Stromversorgung funktioniert einwandfrei. Kein Austausch erforderlich.<\/td>\n<\/tr>\n<tr>\n<td>35\u201337 V (\u00b110%), aber der X-Achsen-Motor funktioniert nicht.<\/td>\n<td>\u2705 Stromversorgung funktioniert einwandfrei \u2192 Fehler liegt nicht an der Stromversorgung<\/td>\n<td>\u00dcberpr\u00fcfen Sie weiterhin die Eingangsspannung des X-Achsen-Motors.<\/td>\n<\/tr>\n<tr>\n<td>0 V oder deutlich zu niedrig (Wechselstromeingang normal best\u00e4tigt)<\/td>\n<td>\u274c Interner Stromversorgungsfehler<\/td>\n<td>Ersetzen Sie das 36V-Netzteil<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Normal-1.webp\" title=\"3.4.1-1-Stromversorgung-Normal\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Normal-1-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Stromversorgung normal\" ids=\"16806\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Normal-1-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Normal-1-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Normal-1-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Normal-1-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Normal-1-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Normal-1-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Normal-1.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.4.1-1-Stromversorgung-Normal<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Abnormal-1.webp\" title=\"3.4.1-2-Stromversorgungsst\u00f6rung\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Abnormal-1-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Stromversorgungsproblem\" ids=\"16807\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Abnormal-1-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Abnormal-1-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Abnormal-1-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Abnormal-1-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Abnormal-1-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Abnormal-1-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Abnormal-1.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.4.1-2-Stromversorgungsst\u00f6rung<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<h4>3.4.2 Weitere \u00dcberpr\u00fcfung der Eingangsspannung des X-Achsen-Motors<\/h4>\n<table>\n<thead>\n<tr>\n<th>Eingangsspannung<\/th>\n<th>Fehlerbeurteilung<\/th>\n<th>Aktion<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>0,0 V<\/td>\n<td>Der X-Achsen-Motor erh\u00e4lt keinen Strom \u2192 Kabelbruch \/ Oxidation der Anschl\u00fcsse<\/td>\n<td>Pr\u00fcfen Sie den Zustand des Kabels und tauschen Sie es gegebenenfalls aus.<\/td>\n<\/tr>\n<tr>\n<td>35\u201337 V (\u00b110%), aber der X-Achsen-Motor funktioniert nicht.<\/td>\n<td>Ausfall des X-Achsen-Motors<\/td>\n<td>Tauschen Sie den X-Achsen-Motor aus.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/X-Axis-Motor-Input-Voltage-Measurement.webp\" title=\"3.4.2-X-Achsen-Motor-Eingangsspannungsmessung\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/X-Axis-Motor-Input-Voltage-Measurement-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Eingangsspannungsmessung des X-Achsen-Motors\" ids=\"16808\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/X-Axis-Motor-Input-Voltage-Measurement-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/X-Axis-Motor-Input-Voltage-Measurement-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/X-Axis-Motor-Input-Voltage-Measurement-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/X-Axis-Motor-Input-Voltage-Measurement-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/X-Axis-Motor-Input-Voltage-Measurement-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/X-Axis-Motor-Input-Voltage-Measurement-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/X-Axis-Motor-Input-Voltage-Measurement.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.4.2-X-Achsen-Motor-Eingangsspannungsmessung<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-812372229\">\n\n\t<div id=\"col-2139351026\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<span class=\"scroll-to\" data-label=\"Scroll to: #power-supply-replacement-procedure\" data-bullet=\"true\" data-link=\"#power-supply-replacement-procedure\" data-title=\"Power Supply Replacement Procedure\"><a name=\"power-supply-replacement-procedure\"><\/a><\/span>\n<h2>4. Vorgehensweise zum Austausch des Netzteils<\/h2>\n<h3>4.1 Schalten Sie das Ger\u00e4t aus.<\/h3>\n<ul>\n<li>Dr\u00fccken Sie den Not-Aus-Schalter<\/li>\n<li>Hauptstrom abschalten<\/li>\n<li>Ziehen Sie den Netzstecker (siehe Abbildungen 4.1-1 \/ 4.1-2).<\/li>\n<\/ul>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch.webp\" title=\"4.1-1-Not-Aus-Schalter\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Not-Ausschalter\" ids=\"16444\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.1-1-Not-Aus-Schalter<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off.webp\" title=\"4.1-2-Ausschalten\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Strom aus\" ids=\"16445\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Serie-Power-Off.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.1-2-Ausschalten<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1508743305\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>4.2 Altes Netzteil ausbauen<\/h3>\n<h4>4.2.1 Kabel trennen<\/h4>\n<p>L\u00f6sen Sie gem\u00e4\u00df Abbildung 2 die mit \u2460\u2013\u2466 nummerierten Klemmschrauben der Reihe nach.<br \/>Trennen Sie die Kabel nacheinander und fotografieren Sie den Kabelverlauf, um sie sp\u00e4ter korrekt wieder anzuschlie\u00dfen.<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Wiring-Record.webp\" title=\"4.2.1-Stromversorgungs-Verkabelungsprotokoll\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Wiring-Record-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Verdrahtungsprotokoll der Stromversorgung\" ids=\"16809\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Wiring-Record-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Wiring-Record-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Wiring-Record-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Wiring-Record-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Wiring-Record-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Wiring-Record-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Power-Supply-Wiring-Record.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.2.1-Stromversorgungs-Verkabelungsprotokoll<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<h4>4.2.2 Befestigungsschrauben entfernen<\/h4>\n<p>L\u00f6sen Sie die Befestigungsschraube \u2460 und die Positionierungsschraube \u2461 und entfernen Sie dann das alte Netzteil.<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Power-Supply-Screws.webp\" title=\"4.2.2-1-L\u00f6sen der Netzteilschrauben\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Power-Supply-Screws-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"L\u00f6sen der Schrauben des Netzteils\" ids=\"16810\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Power-Supply-Screws-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Power-Supply-Screws-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Power-Supply-Screws-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Power-Supply-Screws-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Power-Supply-Screws-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Power-Supply-Screws-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Loosening-Power-Supply-Screws.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.2.2-1-L\u00f6sen der Netzteilschrauben<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-36V-Power-Supply.webp\" title=\"4.2.2-2-Altes-36V-Netzteil\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-36V-Power-Supply-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Altes 36V-Netzteil\" ids=\"16811\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-36V-Power-Supply-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-36V-Power-Supply-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-36V-Power-Supply-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-36V-Power-Supply-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-36V-Power-Supply-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-36V-Power-Supply-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Old-36V-Power-Supply.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.2.2-2-Altes-36V-Netzteil<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1145930190\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>4.3 Installieren Sie das neue Netzteil<\/h3>\n<h4>4.3.1 Modellkonsistenz best\u00e4tigen<\/h4>\n<p>Stellen Sie sicher, dass das neue Netzteilmodell mit dem alten \u00fcbereinstimmt.<\/p>\n<h4>4.3.2 Sichere Installation<\/h4>\n<p>Richten Sie die Befestigungsl\u00f6cher aus, positionieren Sie das Netzteil korrekt und ziehen Sie die Schrauben fest.<\/p>\n<h4>4.3.3 Kabelanschluss<\/h4>\n<p>Schlie\u00dfen Sie alle Kabel in der angegebenen Reihenfolge gem\u00e4\u00df Abbildung 2 wieder an.<br \/>Achten Sie darauf, dass jedes Kabel vollst\u00e4ndig eingef\u00fchrt, richtig ausgerichtet und fest angezogen ist.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1011558996\">\n\n\t<div id=\"col-694740768\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<span class=\"scroll-to\" data-label=\"Scroll to: #power-on-inspection\" data-bullet=\"true\" data-link=\"#power-on-inspection\" data-title=\"Power-On Inspection\"><a name=\"power-on-inspection\"><\/a><\/span>\n<h2>5. \u00dcberpr\u00fcfung beim Einschalten<\/h2>\n<p>5.1 Nachdem alle Kabel angeschlossen sind, \u00fcberpr\u00fcfen Sie erneut, ob sie fest sitzen.<br \/>5.2 Stecken Sie das Netzkabel ein und schalten Sie den Hauptschalter ein. (Siehe Abbildung 3.1)<br \/>5.3 Drehen Sie den Not-Aus-Schalter im Uhrzeigersinn, um die Stromversorgung wiederherzustellen. (Siehe Abbildung 5.3)<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1.webp\" title=\"5-Not-Aus-Schalter\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Not-Ausschalter der Serie K60\" ids=\"16450\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/K60-Series-Emergency-Switch-1.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>5-Not-Aus-Schalter<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p><strong>5.4 Abschlie\u00dfende Statuspr\u00fcfung<\/strong><\/p>\n<p>\u00dcberpr\u00fcfen Sie nach dem Einschalten des Ger\u00e4ts den Status der Stromversorgung wie folgt:<\/p>\n<ul>\n<li>Pr\u00fcfen Sie die Kontrollleuchte des Netzteils.<\/li>\n<li>Messen Sie die 36V-Ausgangsspannung erneut.<\/li>\n<\/ul>\n<p><strong>\u2705 Normal:<\/strong><\/p>\n<ul>\n<li>Die Kontrollleuchte leuchtet oder blinkt normal.<\/li>\n<li>Die Spannung betr\u00e4gt 35V\u201337V.<\/li>\n<\/ul>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-Situation.webp\" title=\"5.4-1-Normalzustand\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-Situation-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Normale Situation\" ids=\"16813\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-Situation-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-Situation-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-Situation-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-Situation-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-Situation-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-Situation-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Normal-Situation.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>5.4-1-Normalzustand<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p><strong>\u274c Abnormal:<\/strong><\/p>\n<ul>\n<li>Die Kontrollleuchte ist aus oder blinkt unregelm\u00e4\u00dfig.<\/li>\n<li>Die Spannung betr\u00e4gt 00,0 V.<\/li>\n<\/ul>\n<p>Bei Auff\u00e4lligkeiten alle Kabelverbindungen erneut \u00fcberpr\u00fcfen.<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Abnormal-Situation.webp\" title=\"5.4-2-Abnormale-Situation\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Abnormal-Situation-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Abnormale Situation\" ids=\"16814\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Abnormal-Situation-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Abnormal-Situation-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Abnormal-Situation-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Abnormal-Situation-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Abnormal-Situation-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Abnormal-Situation-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/12\/Abnormal-Situation.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>5.4-2-Abnormale-Situation<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-496673925\">\n\n\t<div id=\"col-871667294\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<p><strong><span style=\"color: #003366;\">Technische Unterst\u00fctzung<\/span><\/strong><br \/>E-Mail: <a href=\"mailto:support@dtflinko.com\">support@dtflinko.com<\/a><br \/>Website: <a href=\"https:\/\/www.dtflinko.com\/de\/\">www.dtflinko.com<\/a><\/p>\n<div class=\"is-divider divider clearfix\" style=\"max-width:1200px;height:2px;\"><\/div>\n<p>\u00a9 2025 LINKO Technical Team. Alle Rechte vorbehalten.<br \/>Die unbefugte Vervielf\u00e4ltigung oder \u00c4nderung dieses Dokuments ist untersagt.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_269147646 {\n  padding-top: 40px;\n  padding-bottom: 40px;\n}\n@media (min-width:850px) {\n  #section_269147646 {\n    padding-top: 60px;\n    padding-bottom: 60px;\n  }\n}\n<\/style>\n\t<\/section>","protected":false},"excerpt":{"rendered":"","protected":false},"author":3,"featured_media":0,"parent":15609,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-blank.php","meta":{"footnotes":""},"class_list":["post-16791","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>K60 Series | 36V Power Supply Inspection &amp; Replacement Guide - LINKO DTF Printer<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.dtflinko.com\/de\/technische-dienstleistungen\/reparatur-des-technischen-betriebs-des-druckers\/k60-serie-36v-netzteil-inspektions-und-austauschleitfaden\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"K60 Series | 36V Power Supply Inspection &amp; Replacement Guide - LINKO DTF Printer\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.dtflinko.com\/de\/technische-dienstleistungen\/reparatur-des-technischen-betriebs-des-druckers\/k60-serie-36v-netzteil-inspektions-und-austauschleitfaden\/\" \/>\n<meta property=\"og:site_name\" content=\"LINKO DTF Printer\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/linkoprinter\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-02T07:54:47+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/03\/2025-linko-dtf-printer-and-uv-dtf-printer.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1080\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@linkoprinter\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/ar\\\/%d8%a7%d9%84%d8%ae%d8%af%d9%85%d8%a7%d8%aa-%d8%a7%d9%84%d9%81%d9%86%d9%8a%d8%a9\\\/%d8%a5%d8%b5%d9%84%d8%a7%d8%ad-%d8%a7%d9%84%d8%aa%d8%b4%d8%ba%d9%8a%d9%84-%d8%a7%d9%84%d9%81%d9%86%d9%8a-%d9%84%d9%84%d8%b7%d8%a7%d8%a8%d8%b9%d8%a9\\\/%d8%af%d9%84%d9%8a%d9%84-%d9%81%d8%ad%d8%b5-%d9%88%d8%a7%d8%b3%d8%aa%d8%a8%d8%af%d8%a7%d9%84-%d9%88%d8%ad%d8%af%d8%a9-%d8%aa%d8%b2%d9%88%d9%8a%d8%af-%d8%a7%d9%84%d8%b7%d8%a7%d9%82%d8%a9-%d9%85%d9%86\\\/\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/ar\\\/%d8%a7%d9%84%d8%ae%d8%af%d9%85%d8%a7%d8%aa-%d8%a7%d9%84%d9%81%d9%86%d9%8a%d8%a9\\\/%d8%a5%d8%b5%d9%84%d8%a7%d8%ad-%d8%a7%d9%84%d8%aa%d8%b4%d8%ba%d9%8a%d9%84-%d8%a7%d9%84%d9%81%d9%86%d9%8a-%d9%84%d9%84%d8%b7%d8%a7%d8%a8%d8%b9%d8%a9\\\/%d8%af%d9%84%d9%8a%d9%84-%d9%81%d8%ad%d8%b5-%d9%88%d8%a7%d8%b3%d8%aa%d8%a8%d8%af%d8%a7%d9%84-%d9%88%d8%ad%d8%af%d8%a9-%d8%aa%d8%b2%d9%88%d9%8a%d8%af-%d8%a7%d9%84%d8%b7%d8%a7%d9%82%d8%a9-%d9%85%d9%86\\\/\",\"name\":\"K60 Series | 36V Power Supply Inspection & Replacement Guide - LINKO DTF Printer\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/#website\"},\"datePublished\":\"2025-12-26T07:18:08+00:00\",\"dateModified\":\"2026-02-02T07:54:47+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/ar\\\/%d8%a7%d9%84%d8%ae%d8%af%d9%85%d8%a7%d8%aa-%d8%a7%d9%84%d9%81%d9%86%d9%8a%d8%a9\\\/%d8%a5%d8%b5%d9%84%d8%a7%d8%ad-%d8%a7%d9%84%d8%aa%d8%b4%d8%ba%d9%8a%d9%84-%d8%a7%d9%84%d9%81%d9%86%d9%8a-%d9%84%d9%84%d8%b7%d8%a7%d8%a8%d8%b9%d8%a9\\\/%d8%af%d9%84%d9%8a%d9%84-%d9%81%d8%ad%d8%b5-%d9%88%d8%a7%d8%b3%d8%aa%d8%a8%d8%af%d8%a7%d9%84-%d9%88%d8%ad%d8%af%d8%a9-%d8%aa%d8%b2%d9%88%d9%8a%d8%af-%d8%a7%d9%84%d8%b7%d8%a7%d9%82%d8%a9-%d9%85%d9%86\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.dtflinko.com\\\/ar\\\/%d8%a7%d9%84%d8%ae%d8%af%d9%85%d8%a7%d8%aa-%d8%a7%d9%84%d9%81%d9%86%d9%8a%d8%a9\\\/%d8%a5%d8%b5%d9%84%d8%a7%d8%ad-%d8%a7%d9%84%d8%aa%d8%b4%d8%ba%d9%8a%d9%84-%d8%a7%d9%84%d9%81%d9%86%d9%8a-%d9%84%d9%84%d8%b7%d8%a7%d8%a8%d8%b9%d8%a9\\\/%d8%af%d9%84%d9%8a%d9%84-%d9%81%d8%ad%d8%b5-%d9%88%d8%a7%d8%b3%d8%aa%d8%a8%d8%af%d8%a7%d9%84-%d9%88%d8%ad%d8%af%d8%a9-%d8%aa%d8%b2%d9%88%d9%8a%d8%af-%d8%a7%d9%84%d8%b7%d8%a7%d9%82%d8%a9-%d9%85%d9%86\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/ar\\\/%d8%a7%d9%84%d8%ae%d8%af%d9%85%d8%a7%d8%aa-%d8%a7%d9%84%d9%81%d9%86%d9%8a%d8%a9\\\/%d8%a5%d8%b5%d9%84%d8%a7%d8%ad-%d8%a7%d9%84%d8%aa%d8%b4%d8%ba%d9%8a%d9%84-%d8%a7%d9%84%d9%81%d9%86%d9%8a-%d9%84%d9%84%d8%b7%d8%a7%d8%a8%d8%b9%d8%a9\\\/%d8%af%d9%84%d9%8a%d9%84-%d9%81%d8%ad%d8%b5-%d9%88%d8%a7%d8%b3%d8%aa%d8%a8%d8%af%d8%a7%d9%84-%d9%88%d8%ad%d8%af%d8%a9-%d8%aa%d8%b2%d9%88%d9%8a%d8%af-%d8%a7%d9%84%d8%b7%d8%a7%d9%82%d8%a9-%d9%85%d9%86\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Support &#038; Technical Services\",\"item\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/technicke-sluzby\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Printer Technical Operation &amp; Repair\",\"item\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/technicke-sluzby\\\/oprava-technickeho-provozu-tiskarny\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"K60 Series | 36V Power Supply Inspection &#038; Replacement Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/#website\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/\",\"name\":\"LINKO DTF Printer\",\"description\":\"DTF Printer\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/#organization\",\"name\":\"LINKO\",\"alternateName\":\"LINKO DTF PRINTERS MANUFACTURER\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Linko-logo.png\",\"contentUrl\":\"https:\\\/\\\/www.dtflinko.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Linko-logo.png\",\"width\":1000,\"height\":1000,\"caption\":\"LINKO\"},\"image\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/cs\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/linkoprinter\",\"https:\\\/\\\/x.com\\\/linkoprinter\",\"https:\\\/\\\/www.youtube.com\\\/@LinkoPrinter\",\"https:\\\/\\\/www.instagram.com\\\/linkoprinter\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/dtflinko\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"K60-Serie | Leitfaden zur \u00dcberpr\u00fcfung und zum Austausch des 36-V-Netzteils \u2013 LINKO DTF-Drucker","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.dtflinko.com\/de\/technische-dienstleistungen\/reparatur-des-technischen-betriebs-des-druckers\/k60-serie-36v-netzteil-inspektions-und-austauschleitfaden\/","og_locale":"de_DE","og_type":"article","og_title":"K60 Series | 36V Power Supply Inspection & Replacement Guide - LINKO DTF Printer","og_url":"https:\/\/www.dtflinko.com\/de\/technische-dienstleistungen\/reparatur-des-technischen-betriebs-des-druckers\/k60-serie-36v-netzteil-inspektions-und-austauschleitfaden\/","og_site_name":"LINKO DTF Printer","article_publisher":"https:\/\/www.facebook.com\/linkoprinter","article_modified_time":"2026-02-02T07:54:47+00:00","og_image":[{"width":1080,"height":1080,"url":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/03\/2025-linko-dtf-printer-and-uv-dtf-printer.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_site":"@linkoprinter","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.dtflinko.com\/ar\/%d8%a7%d9%84%d8%ae%d8%af%d9%85%d8%a7%d8%aa-%d8%a7%d9%84%d9%81%d9%86%d9%8a%d8%a9\/%d8%a5%d8%b5%d9%84%d8%a7%d8%ad-%d8%a7%d9%84%d8%aa%d8%b4%d8%ba%d9%8a%d9%84-%d8%a7%d9%84%d9%81%d9%86%d9%8a-%d9%84%d9%84%d8%b7%d8%a7%d8%a8%d8%b9%d8%a9\/%d8%af%d9%84%d9%8a%d9%84-%d9%81%d8%ad%d8%b5-%d9%88%d8%a7%d8%b3%d8%aa%d8%a8%d8%af%d8%a7%d9%84-%d9%88%d8%ad%d8%af%d8%a9-%d8%aa%d8%b2%d9%88%d9%8a%d8%af-%d8%a7%d9%84%d8%b7%d8%a7%d9%82%d8%a9-%d9%85%d9%86\/","url":"https:\/\/www.dtflinko.com\/ar\/%d8%a7%d9%84%d8%ae%d8%af%d9%85%d8%a7%d8%aa-%d8%a7%d9%84%d9%81%d9%86%d9%8a%d8%a9\/%d8%a5%d8%b5%d9%84%d8%a7%d8%ad-%d8%a7%d9%84%d8%aa%d8%b4%d8%ba%d9%8a%d9%84-%d8%a7%d9%84%d9%81%d9%86%d9%8a-%d9%84%d9%84%d8%b7%d8%a7%d8%a8%d8%b9%d8%a9\/%d8%af%d9%84%d9%8a%d9%84-%d9%81%d8%ad%d8%b5-%d9%88%d8%a7%d8%b3%d8%aa%d8%a8%d8%af%d8%a7%d9%84-%d9%88%d8%ad%d8%af%d8%a9-%d8%aa%d8%b2%d9%88%d9%8a%d8%af-%d8%a7%d9%84%d8%b7%d8%a7%d9%82%d8%a9-%d9%85%d9%86\/","name":"K60-Serie | Leitfaden zur \u00dcberpr\u00fcfung und zum Austausch des 36-V-Netzteils \u2013 LINKO DTF-Drucker","isPartOf":{"@id":"https:\/\/www.dtflinko.com\/cs\/#website"},"datePublished":"2025-12-26T07:18:08+00:00","dateModified":"2026-02-02T07:54:47+00:00","breadcrumb":{"@id":"https:\/\/www.dtflinko.com\/ar\/%d8%a7%d9%84%d8%ae%d8%af%d9%85%d8%a7%d8%aa-%d8%a7%d9%84%d9%81%d9%86%d9%8a%d8%a9\/%d8%a5%d8%b5%d9%84%d8%a7%d8%ad-%d8%a7%d9%84%d8%aa%d8%b4%d8%ba%d9%8a%d9%84-%d8%a7%d9%84%d9%81%d9%86%d9%8a-%d9%84%d9%84%d8%b7%d8%a7%d8%a8%d8%b9%d8%a9\/%d8%af%d9%84%d9%8a%d9%84-%d9%81%d8%ad%d8%b5-%d9%88%d8%a7%d8%b3%d8%aa%d8%a8%d8%af%d8%a7%d9%84-%d9%88%d8%ad%d8%af%d8%a9-%d8%aa%d8%b2%d9%88%d9%8a%d8%af-%d8%a7%d9%84%d8%b7%d8%a7%d9%82%d8%a9-%d9%85%d9%86\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.dtflinko.com\/ar\/%d8%a7%d9%84%d8%ae%d8%af%d9%85%d8%a7%d8%aa-%d8%a7%d9%84%d9%81%d9%86%d9%8a%d8%a9\/%d8%a5%d8%b5%d9%84%d8%a7%d8%ad-%d8%a7%d9%84%d8%aa%d8%b4%d8%ba%d9%8a%d9%84-%d8%a7%d9%84%d9%81%d9%86%d9%8a-%d9%84%d9%84%d8%b7%d8%a7%d8%a8%d8%b9%d8%a9\/%d8%af%d9%84%d9%8a%d9%84-%d9%81%d8%ad%d8%b5-%d9%88%d8%a7%d8%b3%d8%aa%d8%a8%d8%af%d8%a7%d9%84-%d9%88%d8%ad%d8%af%d8%a9-%d8%aa%d8%b2%d9%88%d9%8a%d8%af-%d8%a7%d9%84%d8%b7%d8%a7%d9%82%d8%a9-%d9%85%d9%86\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.dtflinko.com\/ar\/%d8%a7%d9%84%d8%ae%d8%af%d9%85%d8%a7%d8%aa-%d8%a7%d9%84%d9%81%d9%86%d9%8a%d8%a9\/%d8%a5%d8%b5%d9%84%d8%a7%d8%ad-%d8%a7%d9%84%d8%aa%d8%b4%d8%ba%d9%8a%d9%84-%d8%a7%d9%84%d9%81%d9%86%d9%8a-%d9%84%d9%84%d8%b7%d8%a7%d8%a8%d8%b9%d8%a9\/%d8%af%d9%84%d9%8a%d9%84-%d9%81%d8%ad%d8%b5-%d9%88%d8%a7%d8%b3%d8%aa%d8%a8%d8%af%d8%a7%d9%84-%d9%88%d8%ad%d8%af%d8%a9-%d8%aa%d8%b2%d9%88%d9%8a%d8%af-%d8%a7%d9%84%d8%b7%d8%a7%d9%82%d8%a9-%d9%85%d9%86\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.dtflinko.com\/cs\/"},{"@type":"ListItem","position":2,"name":"Support &#038; Technical Services","item":"https:\/\/www.dtflinko.com\/cs\/technicke-sluzby\/"},{"@type":"ListItem","position":3,"name":"Printer Technical Operation &amp; Repair","item":"https:\/\/www.dtflinko.com\/cs\/technicke-sluzby\/oprava-technickeho-provozu-tiskarny\/"},{"@type":"ListItem","position":4,"name":"K60 Series | 36V Power Supply Inspection &#038; Replacement Guide"}]},{"@type":"WebSite","@id":"https:\/\/www.dtflinko.com\/cs\/#website","url":"https:\/\/www.dtflinko.com\/cs\/","name":"LINKO DTF Drucker","description":"DTF Drucker","publisher":{"@id":"https:\/\/www.dtflinko.com\/cs\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.dtflinko.com\/cs\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.dtflinko.com\/cs\/#organization","name":"LINKO","alternateName":"LINKO DTF PRINTERS MANUFACTURER","url":"https:\/\/www.dtflinko.com\/cs\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.dtflinko.com\/cs\/#\/schema\/logo\/image\/","url":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/09\/Linko-logo.png","contentUrl":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/09\/Linko-logo.png","width":1000,"height":1000,"caption":"LINKO"},"image":{"@id":"https:\/\/www.dtflinko.com\/cs\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/linkoprinter","https:\/\/x.com\/linkoprinter","https:\/\/www.youtube.com\/@LinkoPrinter","https:\/\/www.instagram.com\/linkoprinter\/","https:\/\/www.linkedin.com\/company\/dtflinko\/"]}]}},"_links":{"self":[{"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/pages\/16791","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/comments?post=16791"}],"version-history":[{"count":14,"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/pages\/16791\/revisions"}],"predecessor-version":[{"id":17513,"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/pages\/16791\/revisions\/17513"}],"up":[{"embeddable":true,"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/pages\/15609"}],"wp:attachment":[{"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/media?parent=16791"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}