{"id":16341,"date":"2025-11-28T00:49:51","date_gmt":"2025-11-28T08:49:51","guid":{"rendered":"https:\/\/www.dtflinko.com\/?page_id=16341"},"modified":"2026-05-22T20:09:59","modified_gmt":"2026-05-23T04:09:59","slug":"austausch-des-tintenstationssensors","status":"publish","type":"page","link":"https:\/\/www.dtflinko.com\/de\/technical-services\/printer-technical-operation-repair\/ink-station-sensor-check-replacement\/","title":{"rendered":"\u00dcberpr\u00fcfung und Austausch des Tintenstationssensors"},"content":{"rendered":"<section class=\"section\" id=\"section_1438409450\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row\"  id=\"row-1124810809\">\n\n\t<div id=\"col-795125820\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h1>Leitfaden zur Inspektion und zum Austausch des Tintenstationssensors<\/h1>\n<p><strong>Anwendbares Modell:<\/strong> LINKO K605B DTF-Drucker<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1510017795\">\n\n\t<div id=\"col-1808251060\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h2>Schritt 1. Vorbereitung<\/h2>\n<p>1.1 <strong>Not-Aus-Schalter bet\u00e4tigen:<\/strong> Dr\u00fccken Sie es herunter, um jegliche Bewegung zu stoppen. (Siehe Abbildung 1.1)<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B.webp\" title=\"1.1-Not-Schalter\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Not-Ausschalter\" ids=\"16344\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>1.1-Not-Schalter<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>1.2 Sicherheitshinweis: Schalten Sie die Stromzufuhr ab und ziehen Sie den Netzstecker, bevor Sie mit den Arbeiten beginnen.<\/p>\n<p>Dadurch wird eine Besch\u00e4digung des Tintenstationssensors verhindert und ein elektrischer Schlag vermieden.<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-Off-Carriage-Board-Replacement-and-Wiring.webp\" title=\"1.2-1-Ausschalten\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-Off-Carriage-Board-Replacement-and-Wiring-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Austausch und Verkabelung der Abschaltwagenplatine\" ids=\"15707,15646\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-Off-Carriage-Board-Replacement-and-Wiring-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-Off-Carriage-Board-Replacement-and-Wiring-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-Off-Carriage-Board-Replacement-and-Wiring-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-Off-Carriage-Board-Replacement-and-Wiring-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-Off-Carriage-Board-Replacement-and-Wiring-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-Off-Carriage-Board-Replacement-and-Wiring-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-Off-Carriage-Board-Replacement-and-Wiring.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>1.2-1-Ausschalten<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-On-Replace-Mainboard-and-Wiring.webp\" title=\"1.2-2-Einschalten\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-On-Replace-Mainboard-and-Wiring-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Einschalten, Mainboard und Verkabelung ersetzen\" ids=\"15707,15646\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-On-Replace-Mainboard-and-Wiring-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-On-Replace-Mainboard-and-Wiring-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-On-Replace-Mainboard-and-Wiring-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-On-Replace-Mainboard-and-Wiring-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-On-Replace-Mainboard-and-Wiring-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-On-Replace-Mainboard-and-Wiring-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/10\/Power-On-Replace-Mainboard-and-Wiring.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>1.2-2-Einschalten<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>1.3 <strong>Tipp: Machen Sie ein klares Foto<\/strong> des Tintenstationssensors und seiner Verkabelung.<br \/>Dieses Foto hilft Ihnen bei der korrekten Wiedermontage des Sensors.<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Photo.webp\" title=\"1.3-Cap-Sensor-Photo\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Photo-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Kappensensor-Foto\" ids=\"16345\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Photo-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Photo-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Photo-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Photo-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Photo-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Photo-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Photo.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>1.3-Cap-Sensor-Photo<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-2041880554\">\n\n\t<div id=\"col-1886884748\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h2>Schritt 2. Entfernen Sie den alten Tintenstationssensor<\/h2>\n<p>L\u00f6sen Sie die Schraube, mit der der Sensor der Tintenstation befestigt ist. (Siehe Abbildung 2.1)<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Screw.webp\" title=\"2.1-Kappe-Sensor-Schraube\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Screw-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Kappensensorschraube\" ids=\"16346\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Screw-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Screw-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Screw-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Screw-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Screw-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Screw-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Cap-Sensor-Screw.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>2.1-Kappe-Sensor-Schraube<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>2.2 Trennen Sie das Sensorkabel der Tintenstation. (Siehe Abbildung 2.2-1)<\/p>\n<p>Den alten Tintenstationssensor entfernen. (Siehe Abbildung 2.2-2)<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-Cable.webp\" title=\"2.2-1-Tintenstationssensorkabel \">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-Cable-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"das Kappensensorkabel\" ids=\"16347,16348\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-Cable-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-Cable-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-Cable-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-Cable-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-Cable-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-Cable-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-Cable.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>2.2-1-Tintenstationssensorkabel <\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor.webp\" title=\"2.2-2-Tintenstationssensor \">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"der Kappensensor\" ids=\"16347,16348\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/the-Cap-Sensor.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>2.2-2-Tintenstationssensor <\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-604413140\">\n\n\t<div id=\"col-1358524445\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h2>Schritt 3. Installieren Sie den neuen Tintenstationssensor<\/h2>\n<p>3.1 Stellen Sie sicher, dass das neue Sensormodell der Tintenstation mit dem alten \u00fcbereinstimmt.<br \/>3.2 Stecken Sie das Kabel in den neuen Tintenstationssensor. (Siehe Abbildung 3.2)<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Plag-the-Cap-Sensor-Cable-.webp\" title=\"3.2-Anschluss des Kappensensorkabels \">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Plag-the-Cap-Sensor-Cable--500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Stecken Sie das Kappensensorkabel ein\" ids=\"16349\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Plag-the-Cap-Sensor-Cable--500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Plag-the-Cap-Sensor-Cable--1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Plag-the-Cap-Sensor-Cable--400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Plag-the-Cap-Sensor-Cable--768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Plag-the-Cap-Sensor-Cable--16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Plag-the-Cap-Sensor-Cable--600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Plag-the-Cap-Sensor-Cable-.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>3.2-Anschluss des Kappensensorkabels <\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>3.3 Richten Sie die Befestigungsl\u00f6cher aus. Setzen Sie den neuen Tintenstationssensor ein und ziehen Sie die Schraube fest. (Siehe Abbildung 2.1)<\/p>\n<p><strong>Tipp:<\/strong> Nach dem Anschlie\u00dfen des Kabels machen Sie bitte ein deutliches Foto der Verkabelung und senden Sie es zur Best\u00e4tigung an das technische Support-Team von LINKO, bevor Sie das Ger\u00e4t einschalten.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-2022145428\">\n\n\t<div id=\"col-577107812\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h2>Schritt 4. \u00dcberpr\u00fcfung beim Einschalten<\/h2>\n<p>4.1 Stellen Sie sicher, dass das Kabel vollst\u00e4ndig eingesteckt und nicht verpolt ist.<br \/>4.2 Schlie\u00dfen Sie die \u00d6se am Netzkabel an und schalten Sie den Hauptschalter ein. (Siehe Abbildung 1.1-2)<br \/>4.3 Stellen Sie sicher, dass sich der Not-Aus-Schalter in der Position \u201eEntriegelt\u201c befindet. (Siehe Abbildung 4.3)<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-1.webp\" title=\"4.3-Not-Aus-Schalter\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-1-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Not-Ausschalter\" ids=\"16350\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-1-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-1-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-1-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-1-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-1-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-1-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Emergency-Switch-K605B-1.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.3-Not-Aus-Schalter<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>4.4 \u00dcberpr\u00fcfen Sie die Anzeige des Tintenstations-Ausgangssensors auf dem Mainboard.<\/p>\n<p>Beobachten Sie w\u00e4hrend der Referenzfahrt des Wagens die Tintenstationssensoranzeige auf der Hauptplatine:<\/p>\n<p>\u2705 Normal:<br \/>Wenn der Druckvorgang abgeschlossen ist, bedeutet dies, dass die Hauptplatine die Position der Tintenstation korrekt erkennt \u2192 Kontrollleuchte an. (Siehe Abbildung 4.4-1)<br \/>Transport weg, das bedeutet, dass das Sensorsignal der Tintenstation nicht erkannt wurde \u2192 Licht aus. (Siehe Abbildung 4.4-2)<\/p>\n\n  \n    <div class=\"row large-columns-2 medium-columns- small-columns-\" >\n  <div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Normal.webp\" title=\"4.4-1-Home-Sensor-Normal\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Normal-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Heimsensor Normal\" ids=\"16352,16353\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Normal-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Normal-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Normal-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Normal-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Normal-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Normal-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Normal.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.4-1-Home-Sensor-Normal<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><div class=\"gallery-col col\" >\n          <div class=\"col-inner\">\n            <a class=\"image-lightbox lightbox-gallery\" href=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Abnormal.webp\" title=\"4.4-2-Home-Sensor-Abnormal\">            <div class=\"box has-hover gallery-box box-default\">\n              <div class=\"box-image\" >\n                <img decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Abnormal-500x375.webp\" class=\"attachment-medium size-medium\" alt=\"Fehlfunktion des Heimsensors\" ids=\"16352,16353\" style=\"default\" lightbox_image_size=\"original\" columns=\"2\" text_align=\"center\" srcset=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Abnormal-500x375.webp 500w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Abnormal-1024x768.webp 1024w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Abnormal-400x300.webp 400w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Abnormal-768x576.webp 768w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Abnormal-16x12.webp 16w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Abnormal-600x450.webp 600w, https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/11\/Home-Sensor-Abnormal.webp 1280w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>                                                              <\/div>\n              <div class=\"box-text text-center\" >\n                 <p>4.4-2-Home-Sensor-Abnormal<\/p>\n              <\/div>\n            <\/div>\n            <\/a>          <\/div>\n         <\/div><\/div>\n<p>\u274c Abnormal:<br \/>Das Licht bleibt entweder immer an oder immer aus und \u00e4ndert sich nicht mit der Bewegung des Wagens. (Siehe Abbildung 4.4-2)<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-735034328\">\n\n\t<div id=\"col-1864123588\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<p><strong>Anhang \u2013 Wann der Tintenstationssensor ausgetauscht werden muss<\/strong><\/p>\n<p>Der Sensor der Tintenstation sollte unter folgenden Bedingungen ausgetauscht werden:<\/p>\n<ul>\n<li>Das Heimatsignal wird w\u00e4hrend der Wagenortung nicht erkannt.<\/li>\n<li>Die Anzeige f\u00fcr den Tintenstations-Ausgangssensor schaltet sich nicht ein, wenn der Druckkopf die Tintenstation erreicht.<\/li>\n<li>Reinigungs- oder Pumpvorgang startet nicht.<\/li>\n<li>Der Druckkopf kann nicht richtig verschlossen werden.<\/li>\n<li>Das Sensorsignal ist instabil oder intermittierend.<\/li>\n<li>Der Sensor zeigt Verunreinigungen, Korrosion oder physische Besch\u00e4digungen an.<\/li>\n<li>Der Sensor reagiert auch nach erneutem Anschlie\u00dfen oder wiederholten \u00dcberpr\u00fcfungen nicht.<\/li>\n<\/ul>\n<p>Der Sensor der Tintenstation ist ein <strong>elektronisches Verbrauchsmaterial<\/strong>und seine Leistungsf\u00e4higkeit kann sich im Laufe der Zeit aufgrund von Feuchtigkeit, Tintennebel, Vibrationen, Oxidation oder Alterung verschlechtern.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-666326727\">\n\n\t<div id=\"col-350230315\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<p>Bei Fragen wenden Sie sich bitte an das technische Support-Team von LINKO.<\/p>\n<div class=\"is-divider divider clearfix\" style=\"max-width:2000px;height:2px;\"><\/div>\n<p>\u00a9 2025 LINKO Technical Team. Alle Rechte vorbehalten.<br \/>Die Vervielf\u00e4ltigung oder \u00c4nderung dieses Dokuments ist untersagt.<br \/>Unterst\u00fctzung: <a href=\"mailto:support@dtflinko.com\">support@dtflinko.com<\/a> | <a href=\"https:\/\/www.dtflinko.com\/de\/\">www.dtflinko.com<\/a><\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1438409450 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n}\n@media (min-width:550px) {\n  #section_1438409450 {\n    padding-top: 60px;\n    padding-bottom: 60px;\n  }\n}\n<\/style>\n\t<\/section>","protected":false},"excerpt":{"rendered":"","protected":false},"author":3,"featured_media":0,"parent":15609,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-blank.php","meta":{"footnotes":""},"class_list":["post-16341","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Ink Station Sensor Check &amp; Replacement - LINKO DTF Printer<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.dtflinko.com\/de\/technische-dienstleistungen\/reparatur-des-technischen-betriebs-des-druckers\/austausch-des-tintenstationssensors\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Ink Station Sensor Check &amp; Replacement - LINKO DTF Printer\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.dtflinko.com\/de\/technische-dienstleistungen\/reparatur-des-technischen-betriebs-des-druckers\/austausch-des-tintenstationssensors\/\" \/>\n<meta property=\"og:site_name\" content=\"LINKO DTF Printer\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/linkoprinter\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-23T04:09:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/03\/2025-linko-dtf-printer-and-uv-dtf-printer.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1080\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@linkoprinter\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/ink-station-sensor-check-replacement\\\/\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/ink-station-sensor-check-replacement\\\/\",\"name\":\"Ink Station Sensor Check & Replacement - LINKO DTF Printer\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/#website\"},\"datePublished\":\"2025-11-28T08:49:51+00:00\",\"dateModified\":\"2026-05-23T04:09:59+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/ink-station-sensor-check-replacement\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/ink-station-sensor-check-replacement\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/ink-station-sensor-check-replacement\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.dtflinko.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Support &#038; Technical Services\",\"item\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Printer Technical Operation &amp; Repair\",\"item\":\"https:\\\/\\\/www.dtflinko.com\\\/technical-services\\\/printer-technical-operation-repair\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Ink Station Sensor Check &#038; Replacement\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/#website\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/\",\"name\":\"LINKO DTF Printer\",\"description\":\"DTF Printer\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.dtflinko.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/#organization\",\"name\":\"LINKO\",\"alternateName\":\"LINKO DTF PRINTERS MANUFACTURER\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.dtflinko.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Linko-logo.png\",\"contentUrl\":\"https:\\\/\\\/www.dtflinko.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/Linko-logo.png\",\"width\":1000,\"height\":1000,\"caption\":\"LINKO\"},\"image\":{\"@id\":\"https:\\\/\\\/www.dtflinko.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/linkoprinter\",\"https:\\\/\\\/x.com\\\/linkoprinter\",\"https:\\\/\\\/www.youtube.com\\\/@LinkoPrinter\",\"https:\\\/\\\/www.instagram.com\\\/linkoprinter\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/dtflinko\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Tintenstationssensor pr\u00fcfen und austauschen \u2013 LINKO DTF-Drucker","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.dtflinko.com\/de\/technische-dienstleistungen\/reparatur-des-technischen-betriebs-des-druckers\/austausch-des-tintenstationssensors\/","og_locale":"de_DE","og_type":"article","og_title":"Ink Station Sensor Check & Replacement - LINKO DTF Printer","og_url":"https:\/\/www.dtflinko.com\/de\/technische-dienstleistungen\/reparatur-des-technischen-betriebs-des-druckers\/austausch-des-tintenstationssensors\/","og_site_name":"LINKO DTF Printer","article_publisher":"https:\/\/www.facebook.com\/linkoprinter","article_modified_time":"2026-05-23T04:09:59+00:00","og_image":[{"width":1080,"height":1080,"url":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2025\/03\/2025-linko-dtf-printer-and-uv-dtf-printer.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_site":"@linkoprinter","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/ink-station-sensor-check-replacement\/","url":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/ink-station-sensor-check-replacement\/","name":"Tintenstationssensor pr\u00fcfen und austauschen \u2013 LINKO DTF-Drucker","isPartOf":{"@id":"https:\/\/www.dtflinko.com\/#website"},"datePublished":"2025-11-28T08:49:51+00:00","dateModified":"2026-05-23T04:09:59+00:00","breadcrumb":{"@id":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/ink-station-sensor-check-replacement\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/ink-station-sensor-check-replacement\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/ink-station-sensor-check-replacement\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.dtflinko.com\/"},{"@type":"ListItem","position":2,"name":"Support &#038; Technical Services","item":"https:\/\/www.dtflinko.com\/technical-services\/"},{"@type":"ListItem","position":3,"name":"Printer Technical Operation &amp; Repair","item":"https:\/\/www.dtflinko.com\/technical-services\/printer-technical-operation-repair\/"},{"@type":"ListItem","position":4,"name":"Ink Station Sensor Check &#038; Replacement"}]},{"@type":"WebSite","@id":"https:\/\/www.dtflinko.com\/#website","url":"https:\/\/www.dtflinko.com\/","name":"LINKO DTF Drucker","description":"DTF Drucker","publisher":{"@id":"https:\/\/www.dtflinko.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.dtflinko.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.dtflinko.com\/#organization","name":"LINKO","alternateName":"LINKO DTF PRINTERS MANUFACTURER","url":"https:\/\/www.dtflinko.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.dtflinko.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/09\/Linko-logo.png","contentUrl":"https:\/\/www.dtflinko.com\/wp-content\/uploads\/2026\/09\/Linko-logo.png","width":1000,"height":1000,"caption":"LINKO"},"image":{"@id":"https:\/\/www.dtflinko.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/linkoprinter","https:\/\/x.com\/linkoprinter","https:\/\/www.youtube.com\/@LinkoPrinter","https:\/\/www.instagram.com\/linkoprinter\/","https:\/\/www.linkedin.com\/company\/dtflinko\/"]}]}},"_links":{"self":[{"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/pages\/16341","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/comments?post=16341"}],"version-history":[{"count":5,"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/pages\/16341\/revisions"}],"predecessor-version":[{"id":18033,"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/pages\/16341\/revisions\/18033"}],"up":[{"embeddable":true,"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/pages\/15609"}],"wp:attachment":[{"href":"https:\/\/www.dtflinko.com\/de\/wp-json\/wp\/v2\/media?parent=16341"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}